Permits

8521 Younger Creek Dr has 18 permit records of total value of $1,168,844.

Permit History
18
Permits
$1,168,844
Total Permit Value
July 6, 2021
Description: Epc - convert existing 21, 540 sf manufacturing warehouse to cannabis cultivation. Type vb; occ. F-1/b; scope includes accessibility improvements interior partitions plumbing electrical lighting suspended and roof mounting equipment fire sprinkler and alarm system cannabis cultivation equipment and fixtures occupancy class b testing laboratory. - plng-inspJob Value: $518,000Status: completeType: Commercial remodelBusiness Name: Timco Construction IncorporatedFees: $28,844Effective Date: 2021-07-06Permit Number: COM-1808407
May 4, 2020
Description: Epc - revision to com-1808407. *modifications to co2 system; *remove abandoned equipment at roof; *remove clone area; *convert 2 cultivation rooms to product storage; *change electrical panel schedules for installed conditionStatus: completeType: Commercial revisionFees: $1,435Effective Date: 2020-05-04Permit Number: COM-2007356
May 4, 2020
Status: filedType: Commercial plan review submittalEffective Date: 2020-05-04Permit Number: SUB-2007326
March 5, 2020
Description: Expedited - epc - install bollards for vehicle protection at storefront. Life safety approval otc on 3/2/2020. Cannabis cultivation remodel under com-1808407Job Value: $7,350Status: finalType: Commercial other struct (non-bldg)Business Name: Timco Construction IncorporatedFees: $736Effective Date: 2020-03-05Permit Number: COM-2003801
February 26, 2020
Description: Fire sprinklers (16 new) to be installed : adding upright sprinklers to existing overhead serviceJob Value: $2,518Status: finalType: Commercial fire equipmentBusiness Name: Foothill Fire Protection INCFees: $451Effective Date: 2020-02-26Permit Number: COM-2003335
January 30, 2020
Description: Epc - revision to com-1808407. Mep revisions: #1. Room 118 processing. Remove 2- fau's and AC's replacing with 1- 5ton carrier packaged heat pump. 3 phz 208v from panel X #2. Room 120 cultivation. Only one fau is needed in this cultivation room 3. Room 137 and 138 cultivation. Co2 enrichment rooms run 12 spiral to corner of room and drop to 12" above floor to meet requirements on plans. Remove can filters 4. Room 110 lab. 6' hamilton safeaire hood. 9" galv. Pipe to roof. Not 14" stainless. 208v to roof for hood motor 5. Warehouse 115 added 4" vent for dryer. Lab room 110 and lounge 104 added 4" exhaust for equipment 6. Egress path lighting to change from bug-eyes only to distributed throughout light fixturesStatus: completeType: Commercial revisionFees: $626Effective Date: 2020-01-30Permit Number: COM-2001581
January 29, 2020
Description: Epc submittal - deferred/revision to issued permit com-1808407 - 1. Room 118 processing. I'm taking out 2- fau's and AC's replacing with 1- 5ton carrier packaged heat pump. 3 phz 208v from panel X 2. Room 120 cultivation. Only one fau is needed in this cultivation room 3. Room 137 and 138 cultivation. Co2 enrichment rooms I will have to run 12 spiral to corner of room and drop to 12" above floor to meet requirements on plans. Remove can filters 4. Room 110 lab. 6' hamilton safeaire hood. 9" galv. Pipe to roof. Not 14" stainless. 208v to roof for hood motor 5. Warehouse 115 added 4" vent for dryer. Lab room 110 and lounge 104 added 4" exhaust for equipment 6. Egress path lighting to change from bug-eyes only to distributed throughout light fixturesStatus: filedType: Commercial plan review submittalFees: $82Effective Date: 2020-01-29Permit Number: SUB-2001575
July 3, 2019
Description: Convert existing manufacturing warehouse to Cannabis Cultivation: Fire Sprinkler and Alarm system. (See COM-1808407 for interior remodel/change of use scope).Job Value: $32,000Status: expiredType: Commercial Fire EquipmentBusiness Name: Foothill Fire Alarm & Security Inc; Foothill Fire Protection IncFees: $2,332Effective Date: 2019-07-03Permit Number: COM-1808412
May 3, 2019
Description: Epc submittal - remodel of commercial building - convert existing manufacturing warehouse to cannabis cultivation: accessibility improvements interior partitions plumbing electrical lighting suspended and roof mounting equipment fire sprinkler and alarm system cannabis cultivation equipment and fixtures occupancy class b testing laboratory. - plng-inspJob Value: $518,000Status: filedType: Commercial plan review submittalEffective Date: 2019-05-03Permit Number: SUB-1907946
February 5, 2018
Description: Installation of back flow preventerJob Value: $4,900Status: finalType: Commercial minorBusiness Name: J&D Greenberg Enterprises IncFees: $235Effective Date: 2018-02-05Permit Number: COM-1713744
October 29, 1998
Description: Roof evap cooler and six radiant heatersJob Value: $18,000Status: completeType: Building/commercial/addition/industrialBusiness Name: AIR Maximum INCFees: $789Effective Date: 1998-10-29Permit Number: 9810832
October 9, 1997
Job Value: $8,300Status: FinaledType: Building/commercial/addition/industrialBusiness Name: Eagle ElectricFees: $518Effective Date: 1997-10-09Permit Number: 9713891
June 20, 1997
Description: Electrical safety inspectionJob Value: $3,276Status: FinaledType: Building/Archive/Archive/IndustrialEffective Date: 1997-06-20Permit Number: 974882
July 31, 1996
Description: Commercial interior remodelJob Value: $40,000Status: FinaledType: Building/Archive/Archive/Retail StoreEffective Date: 1996-07-31Permit Number: 966405
June 25, 1996
Description: Commercial interior remodelJob Value: $8,300Status: FinaledType: Building/Archive/Archive/IndustrialEffective Date: 1996-06-25Permit Number: 965095
November 9, 1995
Job Value: $3,000Status: FinaledType: Building/Archive/Archive/IndustrialEffective Date: 1995-11-09Permit Number: 953698A
May 1, 1995
Description: Electrical meter box repairJob Value: $5,200Status: FinaledType: Building/Archive/Archive/Retail StoreEffective Date: 1995-05-01Permit Number: 953698
February 14, 1990
Description: SignStatus: FinaledType: Building/Archive/Archive/MiscEffective Date: 1990-02-14Permit Number: S15565

Current Ownership

Information about the current owner(s).

Property History

8521 Younger Creek Dr has undefined property events records (listings, deeds, permits, tax, foreclosure, loan).

Property Events

Environment

Environmental factors around 8521 Younger Creek Dr

School Information

Public/private schools serving 8521 Younger Creek Dr

Neighborhood

This property is located in Florin Fruitridge Industrial Park, Sacramento, CA 95828.

Market Trends

Historical market data near 8521 Younger Creek Dr over selected time period.

Nearby Properties on Younger Creek Dr