10/19/2017
Sold Price
$485,000$396/ft²

5803 Clinton Ave
Minneapolis, MN 55419

5803 Clinton Ave, Minneapolis, MN 55419 is a 3 bed, 2 bath, 1,226 ft² house built in 1934 on a 0.210 acre lot with 51 construction permits. This house is currently off market, and it was last sold in 2017 for $485,000. The latest TopHap estimate of the house's value is $360,750.

Property Valuations

Latest estimates for 5803 Clinton Ave based on TopHap automated valuation model (AVM).

Permits

5803 Clinton Ave has 51 permit records of total value of $364,738.

Permit History
51
Permits
$364,738
Total Permit Value
December 24, 2020
Description: Saverswitchimport53|428Status: finalType: Electrical permitSub Type: Saver switchFees: $20Effective Date: 2020-12-24Permit Number: ELE2012-05373
March 7, 2019
Project Name: OswaldDescription: Wiring of whole house remodelStatus: finalType: Electrical permit; Ele exst 1 or 2 familySub Type: One and two family dwelling; Business Name: Tommys ElectricApplicant: Kathleen OswaldFees: $136Effective Date: 2019-03-07Permit Number: ELE1809-06966
May 23, 2018
Description: REROOF TEAROFF AND REROOF HOUSE - INSPECT DECKING, ICE/WATER SHIELD AND FELT TO CODE. GAF TIMBERLINE SHINGLES. All exterior work to be completed within one year of permit issuance date per Minneapolis City Ordinance 89.165 Carbon monoxide detectors are required in dwelling units in accordance with Minnesota Statute 299F.50. Please refer to the following website for additional information. http://www.doli.state.mn.us/pdf/bcs_co_detectors_joint_memo_july06.pdfStatus: finalType: ResidentialApplicant: Kathleen A OswaldEffective Date: 2018-05-23Permit Number: BLDG146573
March 9, 2018
Project Name: Electrical Furnace Hook up- infoferDescription: Final wiring for furnace replacementStatus: finalType: Ele new 1 or 2 familyBusiness Name: Deans Professional Plumbing IncApplicant: Greg InhoferFees: $36Effective Date: 2018-03-09Permit Number: ELE1803-00085
February 27, 2018
Project Name: Wire FurnaceStatus: finalType: Ele exst 1 or 2 familySub Type: Residential exstBusiness Name: Spark Electric COApplicant: Kathleen OswaldFees: $36Effective Date: 2018-02-27Permit Number: ELE1712-00647
February 27, 2018
Project Name: WIRE REZNOR HEATERStatus: finalType: Electrical permit; Ele exst 1 or 2 familySub Type: One and two family dwelling; Residential exstBusiness Name: Spark Electric CoApplicant: Kathleen OswaldFees: $36Effective Date: 2018-02-27Permit Number: ELE1802-04153
February 1, 2018
Description: Garage heaterStatus: completeType: MechanicalBusiness Name: Standard Heating & AIR Conditioning INCApplicant: Kathleen A OswaldFees: $128Effective Date: 2018-02-01Permit Number: BLDG689285
December 20, 2017
Description: Replace furnaceStatus: completeType: MechanicalBusiness Name: Standard Heating & AIR Conditioning INCApplicant: Kathleen A OswaldFees: $128Effective Date: 2017-12-20Permit Number: BLDG686536
May 5, 2015
Description: Tearoff and reroof house - inspect decking ice/water shield and felt to code. Gaf timberline shinglesJob Value: $6,900Status: OpenType: Building over the counterSub Type: BotcBusiness Name: Precision Home ConstructionApplicant: Chris GulbrandsonFees: $202Effective Date: 2015-05-05Permit Number: 1119665
September 29, 2011
Description: MAS/CONCRT DEMO BRICK CHIMNEY TO ROOFLINE AND REBUILD. RECAP WITH CEMENT TERMINAL CAPS. REFLASH @ ROOFLINE SHINGLE AS NEEDED M.C.O. 89.165 Completion of work - All work for altering, repairing, or remodeling the exterior portion of a single-family dwelling or two-family dwelling, including an attached or detached garage, shall be completed within one 1) year from the date of issuance of the building permit. Carbon monoxide detectors are required in dwelling units in accordance with Minnesota Statute 299F.50. Please refer to the following website for additional information. http://www.doli.state.mn.us/pdf/bcs_co_detectors_joint_memo_july06.pdfStatus: finalType: ResidentialApplicant: Kathleen A OswaldEffective Date: 2011-09-29Permit Number: BLDG132575
August 29, 2011
Description: Demolish brick chimney to roofline and rebuild. Recap with cement terminal capsStatus: DoneType: Building over the counterSub Type: BotcBusiness Name: Precision Home ConstructionApplicant: Chris GulbrandsonFees: $149Effective Date: 2011-08-29Permit Number: 1097194
August 26, 2011
Description: Street use permit is valid for ____ days from date of issuanceStatus: DoneType: Street use permitSub Type: BsuBusiness Name: Lloyd's Construction Services, IncApplicant: Chris GulbrandsonFees: $74Effective Date: 2011-08-26Permit Number: 1032784
March 25, 2010
Description: WATER HTR Replace existing water heater - Is this a gas water heater(y/n)?__Y_ - Is this an electric water heater(y/n)?__ NOTE: an electric water heater replacement also requires an Electrical permit - Other: describe below Carbon monoxide detectors are required in dwelling units in accordance with Minnesota Statute 299F.50. Please refer to the following website for additional information. http://www.doli.state.mn.us/pdf/bcs_co_detectors_joint_memo_july06.pdfStatus: finalType: PlumbingApplicant: Kathleen A OswaldEffective Date: 2010-03-25Permit Number: BLDG473996
February 23, 2010
Description: Replace existing water heaterStatus: DoneType: plumbingSub Type: BtpaBusiness Name: Champion Plumbing, LlcApplicant: Chris GulbrandsonFees: $70Effective Date: 2010-02-23Permit Number: 5113590
May 12, 2005
Description: R3/REM FINISH FORMER ATTACHED GARAGE (BASEMENT LEVEL) FOR FAMILY ROOM. DTC-2 INSTALL PATIO DOOR AND WINDOW. Bsement and insulation bulletins attached. R317.1.1 Alterations, repairs or additions. When interior alterations, repairs or additions requiring a permit occur, or when one or more sleeping rooms are added or created in existing dwellings, the individual dwelling unit shall be provided with smoke alarms located as required for new dwellings; the smoke alarms shall be interconnected and hardwired. Exceptions: 1. Smoke alarms in existing areas shall not be required to be interconnected and hardwired where the alterations or repairs do not result in the removal of interior wall or ceiling finishes exposing the structure, unless there is a crawl space or basement available which could provide access for hardwiring and interconnection without the removal of interior finishes. 2. Work on the exterior which does not require entry into the interior for inspection.Status: finalType: CommercialApplicant: Kathleen A OswaldEffective Date: 2005-05-12Permit Number: BLDG214039
May 10, 2005
Description: plumbing fix specify the type of fixtures by entering the quantity in the list below: water closets_1___ urinals_____ bathroom tubs____ basins__1__ sinks_____ wash trays_____ showers__1___ floor drains___1_ extensions__1___ misc fixtures____ electric water heaters_____ other: specify below addition 3/4 bathroom to basement owner's name _craig opitz phone#Status: finalType: plumbingBusiness Name: Den Mark Plumbing IncApplicant: Kathleen A OswaldEffective Date: 2005-05-10Permit Number: BLDG429755
March 30, 2005
Description: MECH MECH | WARM AIR HEATING SYSTEMS | Scope of work: ADD 3 SUPPLIES AND 1 COLD AIR RETURN, VENT BATH EXHAUST FAN MECH | Scope of work: ADD 3 SUPPLIES AND 1 COLD AIR RETURN, VENT BATH EXHAUST FAN MECH | Scope of work: ADD 3 SUPPLIES AND 1 COLD AIR RETURN, VENT BATH EXHAUST FAN MECH | Scope of work: ADD 3 SUPPLIES AND 1 COLD AIR RETURN, VENT BATH EXHAUST FANStatus: finalType: MechanicalBusiness Name: Marsh Heating & A / C Co IncApplicant: Kathleen A OswaldEffective Date: 2005-03-30Permit Number: BLDG276777
February 28, 2005
Description: Finish basement 4 cktsStatus: DoneType: ElectricalSub Type: BteaBusiness Name: Kovar Electric LlcApplicant: Chris GulbrandsonFees: $56Effective Date: 2005-02-28Permit Number: 1077654
February 2, 2005
Description: Addition 3 supplies and 1 cold air return vent bathroom exhaust fanJob Value: $1,000Status: DoneType: MechanicalSub Type: BtmaBusiness Name: Marsh Heating & A/c Co, IncApplicant: Chris GulbrandsonFees: $56Effective Date: 2005-02-02Permit Number: 4050304
January 24, 2005
Description: Specify the type of fixtures by entering the quantity in the list below:Status: DoneType: plumbingSub Type: BtpaBusiness Name: Den-mark Plumbing, IncApplicant: Chris GulbrandsonFees: $136Effective Date: 2005-01-24Permit Number: 5061205
January 11, 2005
Description: Non-structural remodel to basement level of single family dwelling including installation of new (dmh#2)Job Value: $16,800Status: DoneType: RemodelingSub Type: BireBusiness Name: Hoffman Remodeling & DesignApplicant: Chris GulbrandsonFees: $330Effective Date: 2005-01-11Permit Number: 3033215
May 18, 2004
Description: ADDITION 22'6" X 26'0" ATTACHED GARAGE WITH ROOF DECK ADDITION TO EXISTING SFD. AAA #1. SEE PLAN FOR DETAILED SCOPE OF WORK TO BE DONE AS WELL AS PLAN REVIEW COMMENTS. GENERAL COMMENTS: Applicant must locate and identify the property stakes and call for inspection for building inspector verification before concrete is poured. APPROVED SITE PLAN AND PERMIT MUST BE ON SITE BEFORE INSPECTIONS WILL BE PROVIDED. SEPARATE ELECTRICAL AND MECHANICAL PERMITS REQUIRED FOR ELECTRICAL AND MECHANICAL WORK. Walls and soffits closer than 3 feet to property lines not adjacent to public right-of-ways must be protected on the interior or exterior face with 5/8" exterior gypsum sheathing, stucco or other approved materials for fire resistance. Openings (windows, etc.) are not permitted in walls closer than 3 feet to property lines not adjacent to public right-of-ways. 12 ft. maximum average roof height Eaves are not permitted to extend closer than 6 in. to property line Anchor bolts must be within 12 in.Status: finalType: ResidentialApplicant: Kathleen A OswaldEffective Date: 2004-05-18Permit Number: BLDG16298
May 18, 2004
Description: REROOF Apply rubber roof over concrete deck at rear of house. All exterior work to be completed within one year of permit issuance per Minneapolis City Ordinance Section 89.165.Status: finalType: ResidentialApplicant: Kathleen A OswaldEffective Date: 2004-05-18Permit Number: BLDG76266
November 24, 2003
Description: MECH MECH | WARM AIR HEATING SYSTEMS | Scope of work: ADD 1 SA AND 1 RA FOR NEW ADDITION CRAIG OPITZ 612-869-5115 MECH | Scope of work: ADD 1 SA AND 1 RA FOR NEW ADDITION CRAIG OPITZ 612-869-5115 MECH | Scope of work: ADD 1 SA AND 1 RA FOR NEW ADDITION CRAIG OPITZ 612-869-5115 MECH | Scope of work: ADD 1 SA AND 1 RA FOR NEW ADDITION CRAIG OPITZ 612-869-5115Status: finalType: MechanicalApplicant: Kathleen A OswaldEffective Date: 2003-11-24Permit Number: BLDG269344
October 6, 2003
Description: Addition 1 sa and 1 ra for new additionJob Value: $1,000Status: DoneType: MechanicalSub Type: BtmaBusiness Name: The Snelling Company, IncApplicant: Chris GulbrandsonFees: $50Effective Date: 2003-10-06Permit Number: 4039174
August 6, 2003
Description: Recps, lights to new room - basement- 3 cktsStatus: DoneType: ElectricalSub Type: BteaBusiness Name: Sherman Electric, IncApplicant: Chris GulbrandsonFees: $52Effective Date: 2003-08-06Permit Number: 1058868
July 30, 2003
Description: Finish former attached garage (basement level) for family room. Dtc-2Job Value: $5,000Status: DoneType: RemodelingSub Type: BireBusiness Name: Craig Opitz (owner)Applicant: Chris GulbrandsonFees: $144Effective Date: 2003-07-30Permit Number: 3022951
June 20, 2003
Description: Apply rubber roof over concrete deck at rear of houseJob Value: $2,569Status: DoneType: RemodelingSub Type: BireBusiness Name: Befort Roofing IncApplicant: Chris GulbrandsonFees: $88Effective Date: 2003-06-20Permit Number: 3022072
October 28, 2002
Description: 22'6 x 26'0 attached garage with roof deck addition to existing single family dwelling. Aaa #1Job Value: $29,000Status: DoneType: RemodelingSub Type: BireBusiness Name: Roepke RenovationsApplicant: Chris GulbrandsonFees: $767Effective Date: 2002-10-28Permit Number: 3017972
January 9, 2002
Description: MECH | Scope of work: INSTALL LINER, REVENT FURNACE & WATER HEATER. (MAC-188) M5434 RR | Scope of work: INSTALL LINER, REVENT FURNACE & WATER HEATER. (MAC-188) M5434 RR | Scope of work: INSTALL LINER, REVENT FURNACE & WATER HEATER. (MAC-188) M5434 RR | Scope of work: INSTALL LINER, REVENT FURNACE & WATER HEATER. (MAC-188) M5434 RRStatus: finalType: MechanicalBusiness Name: Erickson Plbg Htg Ac IncApplicant: Kathleen A Oswald0Effective Date: 2002-01-09Permit Number: BLDG381609
January 8, 2002
Description: INT/EXT MAC 150 SOUND RENOVATIONS All interior and exterior work to be completed within one year of permit issuance per Minneapolis City Ordinance Section 89.165. When the valuation of an addition, alteration, or repair to a dwelling exceeds $1,000 and a permit is required or when one or more sleeping rooms are added or created, smoke detection shall be installed: A. on each level of the house B. in each bedroom C. in the hall or room outside of bedrooms. Detectors may be battery operated, except that where new construction takes place or where the wiring will be exposed, detectors shall be hard-wired with a battery back-up per scope of work on job site.Status: finalType: ResidentialApplicant: Kathleen A OswaldEffective Date: 2002-01-08Permit Number: BLDG192875
September 11, 2001
Description: 100 amp service change. Install 2 fans. (mac-188) m5434 rrJob Value: $3,300Status: DoneType: ElectricalSub Type: BteaBusiness Name: Erickson Plbg, Htg & CoolingApplicant: Chris GulbrandsonFees: $97Effective Date: 2001-09-11Permit Number: 1035658
September 10, 2001
Description: Install liner revent furnace & water heater. (mac-188) m5434 rrJob Value: $1,700Status: DoneType: MechanicalSub Type: BtmaBusiness Name: Erickson Plbg Htg Ac IncApplicant: Chris GulbrandsonFees: $36Effective Date: 2001-09-10Permit Number: 4022499
September 4, 2001
Description: Mac 150 sound renovationsJob Value: $37,750Status: DoneType: Building over the counterSub Type: BotcBusiness Name: Red Rock ConstructionApplicant: Chris GulbrandsonFees: $541Effective Date: 2001-09-04Permit Number: 1038658
July 11, 2001
Description: Layover house roofJob Value: $2,250Status: DoneType: Building over the counterSub Type: BotcBusiness Name: Pates IncApplicant: Chris GulbrandsonFees: $84Effective Date: 2001-07-11Permit Number: 1036860
February 27, 1997
Description: Instl 1-30a ckt finish room in basement residenceStatus: DoneType: ElectricalSub Type: FApplicant: Chris Gulbrandson0Effective Date: 1997-02-27Permit Number: 903502
October 7, 1996
Description: Alter 1 basement room for non-habitable space residenceJob Value: $2,000Status: DoneType: BuildingSub Type: BApplicant: Chris Gulbrandson0Effective Date: 1996-10-07Permit Number: 634879
July 15, 1994
Description: Instl saver switch residenceJob Value: $60Status: DoneType: ElectricalSub Type: FApplicant: Chris Gulbrandson0Effective Date: 1994-07-15Permit Number: 876701
June 29, 1993
Description: Rpl sashes residenceJob Value: $2,900Status: DoneType: BuildingSub Type: BApplicant: Chris Gulbrandson0Effective Date: 1993-06-29Permit Number: 599433
July 31, 1992
Description: Rpl air conditioning residenceJob Value: $150Status: DoneType: ElectricalSub Type: FApplicant: Chris Gulbrandson0Effective Date: 1992-07-31Permit Number: 857397
June 10, 1992
Description: Instl air conditioning pa residenceJob Value: $2,285Status: DoneType: MechanicalSub Type: QApplicant: Chris Gulbrandson0Effective Date: 1992-06-10Permit Number: 76149
May 29, 1992
Description: Wire furnace residenceJob Value: $250Status: DoneType: ElectricalSub Type: FApplicant: Chris Gulbrandson0Effective Date: 1992-05-29Permit Number: 855765
May 7, 1992
Description: Rpl, air conditioning, pw, pa, 1 at 75 gas-br, residenceStatus: DoneType: Gas burnerSub Type: QmApplicant: Chris Gulbrandson0Effective Date: 1992-05-07Permit Number: 75662
January 1, 1900
Description: R3/rem non-structural remodel to basement level of single family dwelling including installation of new (dmh#2) 3/4 bathroom install partition wall for pocket door at laundry room and remove non-bearing center wall between laundry and new bathroom. Install 2 glass blk windows in existing openings. Install 2x framing F.G batts moisture barrier and drywall finish. Use rigid insulation and drywall in closet space. Separate permits are required for electrical plumbing and heating/air conditioning/ventilation work. This work must be completed by a licensed contractor in a multi-family dwelling. Irc 317.1.1. When interior alterations repairs or additions require a building permit or when one or more sleeping rooms are added or created in existing dwellings smoke detection shall be installed: a. On each level of the house b. In each bedroom c. In the hall or room outside of bedrooms. Exceptions: 1. Smoke alarms in existing areas shall not be required to be interconnected and hardwired where tJob Value: $16,800Status: completeType: CommercialBusiness Name: Hoffman Remodeling & DesignApplicant: Kathleen A OswaldEffective Date: 1900-01-01Permit Number: BLDG220706
January 1, 1900
Description: Construct 20 x 4 addition at rear side yard of single family dwelling for new stairway to basement level and new (dmh#1) 2nd floor side yard dormer for 2nd floor bathroom remodel. Partial remodel to kitchen for new addition. Frame and install new main floor 1/2 bathroom adjacent to new front door location. Make structural improvement at basement kitchen and dormer per engineer drawing by wayne larson #7831. Cement fiber-cement or glass mat gypsum backers shall be used as backers for wall tile in bathtub/shower locations and installed per manufacturer recommendations. 2015 mnsbc- irc 702.4.2 approved plans and permit must be on site before inspections will be provided. Smoke detectors and carbon monoxide detectors shall be installed and operable at the time the building inspector performs the final inspection for this permit and in accordance with 2015 mnsbc irc section 314. Carbon monoxide alarms required in accordance with mn. Stat. 299f.50 separate permits are required for electricalJob Value: $174,000Status: completeType: ResidentialBusiness Name: Sylvestre Construction INCApplicant: Kathleen A OswaldFees: $2,814Effective Date: 1900-01-01Permit Number: BLDG726211
January 1, 1900
Description: Supply and vent 2 bathroom fans. Relocate kitchen and master bedroom suppliesStatus: completeType: MechanicalBusiness Name: Sayler Heating & AIR Conditioning INCApplicant: Kathleen A OswaldFees: $84Effective Date: 1900-01-01Permit Number: BLDG737788
January 1, 1900
Description: Kitchen sink & gas cook top replaced in same location half bathroom remodel with 1 toilet & 1 lav and 2nd floor full bathroom includes 2 lavs 1 tub & 1 toiletStatus: completeType: plumbingBusiness Name: Grabow Plumbing INCApplicant: Kathleen A OswaldFees: $357Effective Date: 1900-01-01Permit Number: BLDG743004
January 1, 1900
Description: Replace 8 windows and 1 patio door within existing openingsJob Value: $23,983Status: completeType: ResidentialBusiness Name: Renewal BY Andersen CorpApplicant: Kathleen A OswaldFees: $569Effective Date: 1900-01-01Permit Number: BLDG895736
January 1, 1900
Description: Replace (4) windows in front porch - reframe as needed to repair rotted wood windows installed under this permit shall meet the requirements of the current minnesota state residential code and the minnesota energy code building code: 2020 mnsbc/2018 irc energy code: minnesota rules chapter 1322 separate permits are required for electrical plumbing and heating/air conditioning/ventilation work. Smoke alarms required in accordance with r314 irc 314.3.1. When interior alterations repairs or additions require a building permit or when one or more sleeping rooms are added or created in existing dwellings smoke detection shall be installed: a. On each level of the house b. In each bedroom c. In the hall or room outside of bedrooms. Exceptions: 1. Smoke alarms in existing areas shall not be required to be interconnected and hardwired where the alterations or repairs do not result in the removal of interior wall or ceiling finishes exposing the structure unless there is a crawl space or basemeJob Value: $8,000Status: completeType: ResidentialBusiness Name: Kathleen A OswaldApplicant: Kathleen A OswaldFees: $232Effective Date: 1900-01-01Permit Number: BLDG901869
January 1, 1900
Description: Exterior layover house roof all exterior work to be completed within one year of permit issuance date per minneapolis city ordinance section 89.165Job Value: $2,250Status: completeType: ResidentialBusiness Name: Pates INCApplicant: Kathleen A OswaldEffective Date: 1900-01-01Permit Number: BLDG191536
January 1, 1900
Description: Replacing 12 windows and 1 entry doorJob Value: $24,791Status: filedType: ResidentialBusiness Name: Scherer Brothers Lumber COApplicant: Kathleen A OswaldFees: $590Effective Date: 1900-01-01Permit Number: BLDG949602

Current Ownership

Information about the current owner(s).

Property History

5803 Clinton Ave has undefined property events records (listings, deeds, permits, tax, foreclosure, loan).

Property Events