5344 Bloomington Ave, Minneapolis, MN 55417 is a 2 bed, 2 bath, 1,769 ft² house built in 1929 on a 0.110 acre lot with 32 construction permits. This house is currently off market, and it was last sold in 2004 for $211,000. The latest TopHap estimate of the house's value is $528,341.

Property Valuations

Latest estimates for 5344 Bloomington Ave based on TopHap automated valuation model (AVM).

Permits

5344 Bloomington Ave has 32 permit records of total value of $167,898.

Permit History
32
Permits
$167,898
Total Permit Value
September 3, 2015
Description: *IRC1-ADD CONSTRUCT 29'-6" X 26' 2ND STORY TO SFD FOR 2 BEDROOM & BATHROOM ADDITION WITH (DMH#2) NEW STAIRS FROM 1ST TO 2ND FLOOR. EXISTING STAIRS TO BSMT REMAINS. INSTALL NEW POST AND FOOTING SUPPORT LOCATION IN BASEMENT, WEB FLOOR TRUSSES, FLOOR GIRDERS, LVL BEAMS PER PLAN, F.G BATTS AND BLOWN-IN INSULATION, ROOF TRUSSES AND SHAKE SIDING. REMODEL KITCHEN. CONSTRUCT 20' X8' OPEN FRONT PORCH WITH 2X8 RAFTERS WITH LVL BEAMS, 2X8 TREATED JOISTS AND BEAMS, AND 4 POST FOOTING LOCATIONS. PORCH IS LESS THAN 30" ABOVE GRADE. TEMPERED GLASS SHALL BE INSTALLED AT "HAZARDOUS LOCATIONS" PER 2007 MNSBC CHAPTER 1309 SECTION R308.4 CEMENT, FIBER-CEMENT OR GLASS MAT GYPSUM BACKERS SHALL BE USED AS BACKERS FOR WALL TILE IN BATHTUB/SHOWER LOCATIONS AND INSTALLED PER MANUFACTURER RECOMMENDATIONS - 2007 MNSBC- IRC 702.4.2 SEPARATE PERMITS ARE REQUIRED FOR ELECTRICAL, PLUMBING, AND HEATING/AIR CONDITIONING/VENTILATION WORK. APPLICANT IS REQUIRED TO LOCATE AND IDENTIFY THE PROPERTY STAKES AND CALL BUILDINGStatus: finalType: ResidentialApplicant: Robin FrankeEffective Date: 2015-09-03Permit Number: BLDG67790
September 3, 2015
Description: HVAC-LVL3 | Scope of work: ADD 8 SUPPLY - 3 RA., 1 BATH FAN & DRYER VENT TO ADDITION HVAC WORK AND ENTIRE SYSTEM REPLACEMENT ** Identify number of each of the existing individual heating/cooling system being replaced, that serves an individual dwelling unit. Indicate the number of systems that apply: __Remove existing system and install new (boiler or forced air system) _1_Install a new system to serve an existing non-conditioned space or addition REQUIRED FOR INSPECTION 1. HVAC equipment must be sized to ACCA manual J or an equivalent method. Heat loss calculations to be left next to appliances for inspection. Over-sizing of heating equipment must not exceed 43% and cooling equipment must not exceed 21%. 2. Documents relative to maintenance and startup testing (orsat) shall be affixed to the mechanical equipment. 3. All work done under this permit must be completed by a person with the proper Minneapolis installer competency card employed by the Minneapolis licensed permit applicant. Status: finalType: MechanicalBusiness Name: Heating & Cooling TwoApplicant: Robin FrankeEffective Date: 2015-09-03Permit Number: BLDG374005
May 8, 2015
Description: HVAC W/BNR | Scope of work: HVAC W/BNR - HVAC ALTERATIONS FOR INDIVIDUAL DWELLING UNIT (If multi-unit building, identify the dwelling unit: ____ ) This permit authorizes the following identified mechanical work to replace and/or modify the existing individual heating/cooling system that serves an individual dwelling unit. Check all that apply. __ Replace boiler including piping alterations _y_ Replace furnace including duct alterations __ Add or replace heater for space heating __ Add or replace air conditioner with furnace including duct alterations ITEMS REQUIRED FOR INSPECTION 1. HVAC equipment must be sized according to ACCA manual J or an equivalent method. Calculations to be left next to the new appliances for inspection. Over sizing of heating equipment must not exceed 43% and cooling equipment must not exceed 21%. 2. All documentation relative to maintenance and startup testing (orsat) shall be affixed to the mechanical equipment. 3. All work done under this permit must be compStatus: finalType: MechanicalApplicant: Robin FrankeEffective Date: 2015-05-08Permit Number: BLDG335605
January 9, 2015
Description: PLUM FIX bathroom finish, kitchen finish _______________________________________ Specify the type of fixtures by entering the quantity in the list below: Water Closets____ Urinals_____ Bath Tubs____ Basins____ Sinks_____ Wash Trays_____ Showers_____ Floor Drains____ Extensions_____ Misc Fixtures____ Electric Water Heaters_____ Other: Specify below Properly plug the unused plumbing openings at the nearest live main or branch on the waste and vent system. Cement is not an acceptable method of disconnect. Approved plumbing materials must be used. Dead ends are not permitted except where necessary to extend piping for a cleanout so as to be accessible. The work must be done by a licensed plumbing contractor in which a permit and inspection is required before concealing. Carbon monoxide detectors are required in dwelling units in accordance with Minnesota Statute 299F.50. Please refer to the following website for additional information. http://www.dli.mn.gov/CCLD/PDF/bc_websmoke_co_06_07.pdStatus: finalType: PlumbingApplicant: Robin FrankeEffective Date: 2015-01-09Permit Number: BLDG521683
October 20, 2014
Description: Bathroom finish kitchen finishStatus: DoneType: plumbingSub Type: BtpaBusiness Name: Center Point PlumbingApplicant: Robin M FrankeFees: $385Effective Date: 2014-10-20Permit Number: 5171029
July 17, 2014
Description: Specify the type of fixtures by entering the quantity in the list below:Status: DoneType: plumbingSub Type: BtpaBusiness Name: Center Point PlumbingApplicant: Robin M FrankeFees: $86Effective Date: 2014-07-17Permit Number: 5167565
July 14, 2014
Description: Street use permit is valid for __30__ days from date of issuance. Dumpster - 30 daysStatus: DoneType: Street use permitSub Type: BsuBusiness Name: Atomic RecyclingApplicant: Robin M FrankeFees: $81Effective Date: 2014-07-14Permit Number: 1042174
June 27, 2014
Description: Specify the type of fixtures by entering the quantity in the list below:Status: DoneType: plumbingSub Type: BtpaBusiness Name: Center Point PlumbingApplicant: Robin M FrankeFees: $430Effective Date: 2014-06-27Permit Number: 5167018
June 23, 2014
Description: Addition 8 supply - 3 RA 1 bathroom fan & dryer vent to additionStatus: OpenType: HVAC alterationsSub Type: BtmbBusiness Name: Heating & Cooling TwoApplicant: Robin M FrankeFees: $213Effective Date: 2014-06-23Permit Number: 4108434
June 12, 2014
Description: Street use permit is valid for _30___ days from date of issuanceStatus: DoneType: Street use permitSub Type: BsuBusiness Name: Atomic RecyclingApplicant: Robin M FrankeFees: $81Effective Date: 2014-06-12Permit Number: 1041874
May 20, 2014
Description: Construct 29'-6 x 26 2nd story to single family dwelling for 2 bedroom & bathroom addition with (dmh#2)Job Value: $125,000Status: OpenType: RemodelingSub Type: BireBusiness Name: Prime Project Management IncApplicant: Robin M FrankeFees: $2,776Effective Date: 2014-05-20Permit Number: 3091014
April 21, 2014
Description: Street use permit is valid for _30___ days from date of issuanceStatus: DoneType: Street use permitSub Type: BsuBusiness Name: PodsApplicant: Robin M FrankeFees: $81Effective Date: 2014-04-21Permit Number: 1041313
July 2, 2013
Description: plumbing fix specify the type of fixtures by entering the quantity in the list below: water closets____ urinals_____ bathroom tubs____ basins____ sinks_____ wash trays_____ showers_____ floor drains____ extensions_____ misc fixtures__1__ electric water heaters_____ other: specify below install an ice maker and a gas stove properly plug the unused plumbing openings at the nearest live main or branch on the waste and vent system. Cement is not an acceptable method of disconnect. Approved plumbing materials must be used. Dead ends are not permitted except where necessary to extend piping for a cleanout so as to be accessible. The work must be done by a licensed plumbing contractor in which a permit and inspection is required before concealing. Carbon monoxide detectors are required in dwelling units in accordance with minnesota statute 299f.50. Please refer to the following website for additional information. Http://www.dli.mn.gov/ccld/pdf/bc_websmoke_co_06_07.pdf plans approved by both tStatus: finalType: plumbingBusiness Name: Johnson Plumbing & HeatingApplicant: Robin FrankeEffective Date: 2013-07-02Permit Number: BLDG499508
July 2, 2013
Description: PLUMB MOVE METER FROM INSIDE BUILDING TO OUTSIDE BUILDING Properly plug the unused plumbing openings at the nearest live main or branch on the waste and vent system. Cement is not an acceptable method of disconnect. Approved plumbing materials must be used. Dead ends are not permitted except where necessary to extend piping for a cleanout so as to be accessible. The work must be done by a licensed plumbing contractor in which a permit and inspection is required before concealing. Carbon monoxide detectors are required in dwelling units in accordance with Minnesota Statute 299F.50. Please refer to the following website for additional information. http://www.doli.state.mn.us/pdf/bcs_co_detectors_joint_memo_july06.pdf Plans approved by both the State of Minnesota Department of Health and the Department of Labor and Industry are required to be on site for all plumbing work conducted in hospitals, nursing homes, supervised living facilities, outpatient surgical centers, boarding care homes,Status: finalType: PlumbingBusiness Name: Centerpoint EnergyApplicant: Robin Franke0Effective Date: 2013-07-02Permit Number: BLDG505504
July 1, 2013
Description: Specify the type of fixtures by entering the quantity in the list below:Status: DoneType: plumbingSub Type: BtpaBusiness Name: Johnson Plumbing & HeatingApplicant: Robin M FrankeFees: $112Effective Date: 2013-07-01Permit Number: 5154450
March 18, 2013
Description: plumbing replace gas dryer in basementStatus: finalType: plumbingApplicant: Robin FrankeEffective Date: 2013-03-18Permit Number: BLDG467666
October 17, 2012
Description: HVAC w/bnr - HVAC alterations for individual dwelling unitStatus: OpenType: HVAC alterationsSub Type: BtmbBusiness Name: Ray N. Welter Heating CompanyApplicant: Robin M FrankeFees: $125Effective Date: 2012-10-17Permit Number: 4100760
June 21, 2012
Description: Move meter from inside building to outside buildingStatus: DoneType: plumbingSub Type: BtpaBusiness Name: Centerpoint EnergyApplicant: Robin M FrankeFees: $70Effective Date: 2012-06-21Permit Number: 5140397
April 4, 2008
Description: Replace gas dryer in basementJob Value: $220Status: DoneType: plumbingSub Type: BtpaBusiness Name: Metro Gas InstallersApplicant: Robin M FrankeFees: $66Effective Date: 2008-04-04Permit Number: 5094554
February 22, 2008
Description: Gas fixture replace/installStatus: DoneType: plumbingSub Type: BtpaBusiness Name: Metro Gas InstallersApplicant: Robin M FrankeFees: $64Effective Date: 2008-02-22Permit Number: 5093468
March 15, 2006
Description: MECH MECH | WARM AIR HEATING SYSTEMS | Scope of work: INSTALL 2 TON A/C. [MAC-154]M2463 MECH | Scope of work: INSTALL 2 TON A/C. [MAC-154]M2463 MECH | Scope of work: INSTALL 2 TON A/C. [MAC-154]M2463 MECH | Scope of work: INSTALL 2 TON A/C. [MAC-154]M2463Status: finalType: MechanicalApplicant: Robin FrankeEffective Date: 2006-03-15Permit Number: BLDG365250
November 24, 2003
Description: INT/EXT MISC ALTS (SOUND CONTROL) M2463 All interior and exterior work to be completed within one year of permit issuance per Minneapolis City Ordinance Section 89.165. When the valuation of an addition, alteration, or repair to a dwelling exceeds $1,000 and a permit is required or when one or more sleeping rooms are added or created, smoke detection shall be installed: A. on each level of the house B. in each bedroom C. in the hall or room outside of bedrooms. Detectors may be battery operated, except that where new construction takes place or where the wiring will be exposed, detectors shall be hard-wired with a battery back-up per scope of work on job site.Status: finalType: ResidentialApplicant: Robin FrankeEffective Date: 2003-11-24Permit Number: BLDG175695
September 30, 2002
Description: DET GAR Detached Garage: Construct detached 20 by 20 wood frame garage. GENERAL COMMENTS: APPLICANT MUST LOCATE AND IDENTIFY THE PROPERTY STAKES AND CALL FOR INSPECTION FOR BUILDING INSPECTOR VERIFICATION BEFORE CONCRETE IS POURED. APPROVED SITE PLAN AND PERMIT MUST BE ON SITE BEFORE INSPECTIONS WILL BE PROVIDED. SEPARATE ELECTRICAL AND MECHANICAL PERMITS REQUIRED FOR ELECTRICAL AND MECHANICAL WORK. Walls, soffits, and roof surfaces closer than 3 feet to property lines not adjacent to public right-of-ways must be protected on the exterior face with 5/8" exterior gypsum sheathing, stucco or other approved materials for fire resistance (UBC 503.4.8). Openings (windows, etc.) are not permitted in walls closer than 3 feet to property lines not adjacent to public right-of-ways. 12 ft. maximum average roof height Eaves are not permitted to extend closer than 6 in. to property line Anchor bolts must be within 12 in. of each end of each piece of plate and 6 ft. on center maximum Truss diagramsStatus: finalType: ResidentialApplicant: Robin FrankeEffective Date: 2002-09-30Permit Number: BLDG61213
June 29, 2001
Description: Detached garage:Job Value: $7,808Status: DoneType: RemodelingSub Type: BireBusiness Name: Jason LietzApplicant: Robin M FrankeFees: $157Effective Date: 2001-06-29Permit Number: 3008096
August 25, 1999
Description: Misc alts (sound control) m2463Job Value: $18,800Status: DoneType: Building over the counterSub Type: BotcBusiness Name: Socon Construction IncApplicant: Robin M FrankeFees: $284Effective Date: 1999-08-25Permit Number: 1012877
August 17, 1999
Description: 1 ckt; wire air conditioning 3 lights & install fan mac 154 m2463Job Value: $1,600Status: DoneType: ElectricalSub Type: BteaBusiness Name: Erickson Plbg, Htg & CoolingApplicant: Robin M FrankeFees: $40Effective Date: 1999-08-17Permit Number: 1008368
August 16, 1999
Description: Install 2 ton air conditioning. [mac-154]m2463Job Value: $1,675Status: DoneType: MechanicalSub Type: BtmaBusiness Name: Erickson Plbg, Htg, A/c, IncApplicant: Robin M FrankeFees: $36Effective Date: 1999-08-16Permit Number: 4004929
September 30, 1987
Description: 16x18 room addition to rear of houseJob Value: $8,000Status: DoneType: BuildingSub Type: BApplicant: Robin M Franke0Effective Date: 1987-09-30Permit Number: 553932
January 1, 1900
Description: Gas fix gas fixture replace/install - is this a new install(y/n)?____ - is this a replacement(y/n)?__y__ - fireplace(y/n)?___ - stove(y/n)?__y __ - dryer(y/n)?____ - water heater(y/n)?____ - gas grill(y/n)?____ - other: describe belowStatus: completeType: plumbingBusiness Name: Metro GAS InstallersApplicant: Robin FrankeEffective Date: 1900-01-01Permit Number: BLDG470033
January 1, 1900
Description: plumbing fix specify the type of fixtures by entering the quantity in the list below: water closets____ urinals_____ bathroom tubs____ basins____ sinks_____ wash trays_____ showers_____ floor drains____ extensions_____ misc fixtures____1 electric water heaters_____ other: specify below. Shower pan inspection properly plug the unused plumbing openings at the nearest live main or branch on the waste and vent system. Cement is not an acceptable method of disconnect. Approved plumbing materials must be used. Dead ends are not permitted except where necessary to extend piping for a cleanout so as to be accessible. The work must be done by a licensed plumbing contractor in which a permit and inspection is required before concealing. Carbon monoxide detectors are required in dwelling units in accordance with minnesota statute 299f.50. Please refer to the following website for additional information. Http://www.dli.mn.gov/ccld/pdf/bc_websmoke_co_06_07.pdf plans approved by both the state of miStatus: completeType: plumbingBusiness Name: Center Point PlumbingApplicant: Robin FrankeEffective Date: 1900-01-01Permit Number: BLDG553234
January 1, 1900
Description: plumbing fix specify the type of fixtures by entering the quantity in the list below: water closets_1___ urinals_____ bathroom tubs____ basins____ sinks_3____ wash trays_1____ showers__1___ floor drains____ extensions_____ misc fixtures____ electric water heaters__1___ other: rough-in plumbing only properly plug the unused plumbing openings at the nearest live main or branch on the waste and vent system. Cement is not an acceptable method of disconnect. Approved plumbing materials must be used. Dead ends are not permitted except where necessary to extend piping for a cleanout so as to be accessible. The work must be done by a licensed plumbing contractor in which a permit and inspection is required before concealing. Carbon monoxide detectors are required in dwelling units in accordance with minnesota statute 299f.50. Please refer to the following website for additional information. Http://www.dli.mn.gov/ccld/pdf/bc_websmoke_co_06_07.pdf plans approved by both the state of minnesota deStatus: completeType: plumbingBusiness Name: Center Point PlumbingApplicant: Robin FrankeEffective Date: 1900-01-01Permit Number: BLDG560297
January 1, 1900
Description: Reroof flat roofJob Value: $4,795Status: completeType: ResidentialBusiness Name: Austad Construction INCApplicant: Robin FrankeFees: $168Effective Date: 1900-01-01Permit Number: BLDG901390

Current Ownership

Information about the current owner(s).

Property History

5344 Bloomington Ave has undefined property events records (listings, deeds, permits, tax, foreclosure, loan).

Property Events

Environment

Environmental factors around 5344 Bloomington Ave

School Information

Public/private schools serving 5344 Bloomington Ave

Neighborhood

This property is located in Hale, Minneapolis, MN 55417.

Market Trends

Historical market data near 5344 Bloomington Ave over selected time period.

Nearby Properties on Bloomington Ave