  • Chat with Us
  • Submit Feedback
  • TopHap Academy
  • What's New?
Residential > House
Sold
10/05/2021
Sold Price
$605,000$346/ft²

5336 S Dupont Ave
Minneapolis, MN 55419

5336 S Dupont Ave, Minneapolis, MN 55419 is a 4 bed, 2 bath, 1,748 ft² house built in 1926 on a 0.120 acre lot with 41 construction permits. This house is currently off market, and it was last sold in 2021 for $605,000. The latest TopHap estimate of the house's value is $658,779.

Property Valuations

Latest estimates for 5336 S Dupont Ave based on TopHap automated valuation model (AVM).

Permits

5336 S Dupont Ave has 41 permit records of total value of $133,479.

Permit History
41
Permits
$133,479
Total Permit Value
May 11, 2023
Description: Main service -furnish and install 200a bypass meter socket with integrated main disconnect and circuit breaker spaces to replace 100a meter socket. Replace mast weather head and service conductors. Re-use service entry conduit and conductors -consolidate panels in basement to new 100a 120/240v load center. Reattach branch circuits to new circuit breakers -update grounding bonding and surge protection per nec requirements garage wiring (off peak meter) -trench from new meter socket to garage for 240v 60a car charger. Install charger per home owner. Gfci per nec requirementsStatus: issuedType: Electrical permitSub Type: One-family dwellingApplicant: Brandon OverlandFees: $36Effective Date: 2023-05-11Permit Number: ELE2305-04450
June 15, 2021
Description: Wire new electric water heater. Homeowner switching from gas to electric water heaterStatus: finalType: Electrical permitSub Type: One-family dwellingApplicant: Joe EskolaFees: $36Effective Date: 2021-06-15Permit Number: ELE2106-02585
November 23, 2016
Description: Wire furnaceStatus: ISSUEDType: Ele exst 1 or 2 familySub Type: Residential exstBusiness Name: SPARK ELECTRIC COApplicant: MEGAN & JOE ESKOLAFees: $36Effective Date: 2016-11-23Permit Number: ELE1611-07607
November 23, 2016
Description: | Scope of work: REPLACE FURNACE 1 _______________________________________ HVAC WORK AND REPLACEMENT OF BOILER/FURNACE Identify number of each of the existing individual heating/cooling system being replaced, that serves an individual dwelling unit. Indicate the number of systems that apply: __ Replace boiler plus incidental piping __ Replace furnace only with or without A/C** - plenum included (no duct work beyond plenum) __ Add or replace space heating unit REQUIRED FOR INSPECTION 1. HVAC equipment must be sized to ACCA manual J or an equivalent method. Heat loss calculations to be left next to appliances for inspection. Over-sizing heating equipment must not exceed 43% and cooling equipment must not exceed 21%. 2. Documents relative to maintenance and startup testing (orsat) shall be affixed to the mechanical equipment. 3. All work done under this permit must be completed by a person with the proper Minneapolis installer competency card employed by the Minneapolis licensed permit apStatus: finalType: MechanicalBusiness Name: Standard Heating & Air Conditioning IncApplicant: Joseph P EskolaEffective Date: 2016-11-23Permit Number: BLDG381337
November 2, 2016
Description: Replace furnace 1Status: OpenType: HVAC alterationsSub Type: BtmbBusiness Name: Standard Heating & Air ConditioningApplicant: Joseph P/megan L EskolaFees: $128Effective Date: 2016-11-02Permit Number: 4120617
August 7, 2011
Description: Basement remodelStatus: finalType: Ele exst 1 or 2 familySub Type: Residential exstBusiness Name: Genuine Electric LLCApplicant: Joe EskolaFees: $110Effective Date: 2011-08-07Permit Number: ELE1108-03163
May 26, 2011
Description: *IRC1-R/R PARTIAL FINISH BASEMENT TO DEFINE MECH, LAUNDRY AND BATH AREAS AT SFD (JAG # 2) ADD WALLS BETWEEN AREAS AND ALTER EXISTING AT SUMP AREA IN FAMILY ROOM SPACE. SEPARATE PERMITS ARE REQUIRED FOR ELECTRICAL, PLUMBING, AND HEATING/AIR CONDITIONING/VENTILATION WORK. CARBON MONOXIDE ALARMS REQUIRED IN ACCORDANCE WITH MN. STAT. 299F.50 IRC 313.2.1. When interior alterations, repairs or additions require a building permit or when one or more sleeping rooms are added or created in existing dwellings, smoke detection shall be installed: A. on each level of the house B. in each bedroom C. in the hall or room outside of bedrooms. Exceptions: 1. Smoke alarms in existing areas shall not be required to be interconnected and hardwired where the alterations or repairs do not result in the removal of interior wall or ceiling finishes exposing the structure, unless there is a crawl space or basement available which could provide access for hardwiring and interconnection without the removal of inStatus: finalType: ResidentialApplicant: Joseph P EskolaEffective Date: 2011-05-26Permit Number: BLDG38198
May 12, 2011
Description: Street use permit is valid for 30 days from date of issuanceStatus: DoneType: Street use permitSub Type: BsuBusiness Name: Atomic Recycling LlcApplicant: Joseph P/megan L EskolaFees: $74Effective Date: 2011-05-12Permit Number: 1031213
April 20, 2011
Description: Partial finish basement to define mechanical laundry and bathroom areas at single family dwelling (jag # 2)Job Value: $11,205Status: DoneType: RemodelingSub Type: BireBusiness Name: Ercol ConstructionApplicant: Joseph P/megan L EskolaFees: $386Effective Date: 2011-04-20Permit Number: 3070693
April 11, 2011
Description: Street use permit is valid for 30 days from date of issuanceStatus: DoneType: Street use permitSub Type: BsuBusiness Name: Atomic Recycling LlcApplicant: Joseph P/megan L EskolaFees: $74Effective Date: 2011-04-11Permit Number: 1030908
December 9, 2005
Description: R3/REM CONSTRUCT 11' X 8' DECK OVER EXISTING FLAT ROOF AT FRONT OF SFD. (DMH#2) INSTALL LEDGER BOARD, 2 X 8 TREATED JOISTS, (2) 2 X8 BEAM AND POSTS OVER BEARING WALL WITH NEW METAL GAURDRAIL AND STEEL WIRE. INSTALL "WEATHERBEST" COMPOSITE DECKING (APPRV'D). INSTALL NEW 5' PATIO DOOR AT 2ND FLR AT EXISTING WINDOW OPENING WITH NEW (2) 2X6 HEADER. GENERAL COMMENTS: *INSTALL APPROPRIATE NAILS, BOLTS, SCREWS AND OTHER FASTNERS FOR TREATED WOOD USE. *IF USING PLASTIC DECKING BOARD, SEE HANDOUT LIST FOR APPROVED DECKING MANUFACTURERS. Contact Gopher State One (651-454-0002) prior to digging footings or foundations. 36'' minimum Guardrail height and less than 4'' spacing vertically for decks/landings at 30'' or more above grade. 8'' max. Rise and 9" min. Tread for steps. Grippable handrail height at 34''- 38'' above nose of tread and required at 4 or more risers. Work completed or omitted in violation of the building code shall be corrected as directed by the building Inspector. All interior aStatus: finalType: CommercialApplicant: Joseph P EskolaEffective Date: 2005-12-09Permit Number: BLDG259614
July 14, 2005
Description: Construct 11 x 8 deck over existing flat roof at front of single family dwelling. (dmh#2)Job Value: $12,000Status: DoneType: RemodelingSub Type: BireBusiness Name: Homecare IncApplicant: Joseph P/megan L EskolaFees: $382Effective Date: 2005-07-14Permit Number: 3036430
January 15, 2004
Description: R3/REM Kitchen remodel no structural repairs. R317.1.1 Alterations, repairs or additions. When interior alterations, repairs or additions requiring a permit occur, or when one or more sleeping rooms are added or created in existing dwellings, the individual dwelling unit shall be provided with smoke alarms located as required for new dwellings; the smoke alarms shall be interconnected and hardwired. Exceptions: 1. Smoke alarms in existing areas shall not be required to be interconnected and hardwired where the alterations or repairs do not result in the removal of interior wall or ceiling finishes exposing the structure, unless there is a crawl space or basement available which could provide access for hardwiring and interconnection without the removal of interior finishes. 2. Work on the exterior which does not require entry into the interior for inspection.Status: finalType: CommercialApplicant: Joseph P EskolaEffective Date: 2004-01-15Permit Number: BLDG259325
January 15, 2004
Description: R3/REM RE-STUCCO HOUSE - 250 SQ YDS All interior and exterior work to be completed within one year of permit issuance per Minneapolis City Ordinance Section 89.165. When the valuation of an addition, alteration, or repair to a dwelling exceeds $1,000 and a permit is required or when one or more sleeping rooms are added or created, smoke detection shall be installed: A. on each level of the house B. in each bedroom C. in the hall or room outside of bedrooms. Detectors may be battery operated, except that where new construction takes place or where the wiring will be exposed, detectors shall be hard-wired with a battery back-up per scope of work on job site.Status: finalType: ResidentialApplicant: Joseph P EskolaEffective Date: 2004-01-15Permit Number: BLDG82040
December 23, 2003
Description: plumbing install 1 sk & 1 dishwasherStatus: finalType: plumbingApplicant: Joseph P EskolaEffective Date: 2003-12-23Permit Number: BLDG413749
October 20, 2003
Description: Kitchen remodel 4 cktsStatus: DoneType: ElectricalSub Type: BteaBusiness Name: South Side Electric, IncApplicant: Joseph P/megan L EskolaFees: $52Effective Date: 2003-10-20Permit Number: 1060930
October 1, 2003
Description: Install 1 sk & 1 dishwasherStatus: DoneType: plumbingSub Type: BtpaBusiness Name: Southtown Plumbing IncApplicant: Joseph P/megan L EskolaFees: $52Effective Date: 2003-10-01Permit Number: 5046397
September 12, 2003
Description: Kitchen remodel no structural repairsJob Value: $30,000Status: DoneType: RemodelingSub Type: BireBusiness Name: Homecare IncApplicant: Joseph P/megan L EskolaFees: $467Effective Date: 2003-09-12Permit Number: 3023949
May 9, 2003
Description: Re-stucco house - 250 sq ydsJob Value: $7,650Status: DoneType: Building over the counterSub Type: BotcBusiness Name: Foley Stucco CompanyApplicant: Joseph P/megan L EskolaFees: $162Effective Date: 2003-05-09Permit Number: 1049348
June 6, 2002
Description: DET GAR Detached Garage: Construct detached _22_ by 24__ wood frame garage. GENERAL COMMENTS: APPLICANT MUST LOCATE AND IDENTIFY THE PROPERTY STAKES AND CALL FOR INSPECTION FOR BUILDING INSPECTOR VERIFICATION BEFORE CONCRETE IS POURED. APPROVED SITE PLAN AND PERMIT MUST BE ON SITE BEFORE INSPECTIONS WILL BE PROVIDED. SEPARATE ELECTRICAL AND MECHANICAL PERMITS REQUIRED FOR ELECTRICAL AND MECHANICAL WORK. Walls and soffits closer than 3 feet to property lines not adjacent to public right-of-ways must be protected on the interior or exterior face with 5/8" exterior gypsum sheathing, stucco or other approved materials for fire resistance. Openings (windows, etc.) are not permitted in walls closer than 3 feet to property lines not adjacent to public right-of-ways. 12 ft. maximum average roof height Eaves are not permitted to extend closer than 6 in. to property line Anchor bolts must be within 12 in. of each end of each piece of plate and 6 ft. on center maximum Truss diagrams must be availStatus: finalType: ResidentialApplicant: Joseph P EskolaEffective Date: 2002-06-06Permit Number: BLDG73604
May 28, 2002
Description: New garage wiring with underground feederStatus: DoneType: ElectricalSub Type: BteaBusiness Name: Amp ElectricApplicant: Joseph P/megan L EskolaFees: $36Effective Date: 2002-05-28Permit Number: 1044304
March 20, 2002
Job Value: $10,808Status: DoneType: RemodelingSub Type: BireBusiness Name: Western Const CoApplicant: Joseph P/megan L EskolaFees: $200Effective Date: 2002-03-20Permit Number: 3012437
June 19, 2001
Status: finalType: ResidentialApplicant: Joseph P EskolaEffective Date: 2001-06-19Permit Number: BLDG190466
June 13, 2000
Status: finalType: PlumbingApplicant: Joseph P EskolaEffective Date: 2000-06-13Permit Number: BLDG550383
April 6, 2000
Status: DoneType: ElectricalSub Type: BteaBusiness Name: South Side Electric, IncApplicant: Joseph P/megan L EskolaFees: $40Effective Date: 2000-04-06Permit Number: 1017228
March 6, 2000
Job Value: $15,000Status: DoneType: Building over the counterSub Type: BotcBusiness Name: Homecare IncApplicant: Joseph P/megan L EskolaFees: $232Effective Date: 2000-03-06Permit Number: 1020813
February 16, 2000
Status: DoneType: plumbingSub Type: BtpaBusiness Name: Southtown Plumbing IncApplicant: Joseph P/megan L EskolaFees: $90Effective Date: 2000-02-16Permit Number: 5009735
October 26, 1998
Description: Rpr alum gutters & soffit/fasciaJob Value: $5,000Status: DoneType: BuildingSub Type: BApplicant: Joseph P/megan L Eskola0Effective Date: 1998-10-26Permit Number: 664812
August 20, 1998
Description: Rpl reroof w/tearoff house & garage residenceJob Value: $5,725Status: DoneType: BuildingSub Type: BApplicant: Joseph P/megan L Eskola0Effective Date: 1998-08-20Permit Number: 660067
March 5, 1998
Description: Instl 1 ckt (savers switch) residenceJob Value: $75Status: DoneType: ElectricalSub Type: FApplicant: Joseph P/megan L Eskola0Effective Date: 1998-03-05Permit Number: 913894
January 21, 1998
Description: Admin permit repl b638354; rpl 30 vinyl wndw xJob Value: $15,563Status: DoneType: BuildingSub Type: BApplicant: Joseph P/megan L Eskola0Effective Date: 1998-01-21Permit Number: 651276
December 30, 1997
Description: Instl 2 ckts (bathroom rmdl; misc) residenceJob Value: $550Status: DoneType: ElectricalSub Type: FApplicant: Joseph P/megan L Eskola0Effective Date: 1997-12-30Permit Number: 911907
December 29, 1997
Description: Instl 1bn 1sw s-1wcJob Value: $750Status: DoneType: plumbingSub Type: DApplicant: Joseph P/megan L Eskola0Effective Date: 1997-12-29Permit Number: 953644
December 15, 1997
Description: Rpr tile basement shower residenceJob Value: $2,500Status: DoneType: BuildingSub Type: BApplicant: Joseph P/megan L Eskola0Effective Date: 1997-12-15Permit Number: 650436
August 19, 1997
Description: Rpl 7 basement wndws w/glass blk vented no structrlJob Value: $900Status: DoneType: BuildingSub Type: BApplicant: Joseph P/megan L Eskola0Effective Date: 1997-08-19Permit Number: 645408
February 27, 1997
Description: Rpl 30 vinyl windows;cover w/alum brickmold trimxJob Value: $15,563Status: DoneType: BuildingSub Type: BApplicant: Joseph P/megan L Eskola0Effective Date: 1997-02-27Permit Number: 638354
July 2, 1996
Description: Alter 2 ckts:wire furnace & air conditioningJob Value: $190Status: DoneType: ElectricalSub Type: FApplicant: Joseph P/megan L Eskola0Effective Date: 1996-07-02Permit Number: 896518
June 11, 1996
Description: Instl air conditioning, pw, pa 1-80 btu gas-br, residenceStatus: DoneType: Gas burnerSub Type: QmApplicant: Joseph P/megan L Eskola0Effective Date: 1996-06-11Permit Number: 101788
January 1, 1900
Description: Replace water heaterStatus: completeType: plumbingBusiness Name: Water Heaters NOW INCApplicant: Brandon J OverlandFees: $85Effective Date: 1900-01-01Permit Number: BLDG892357
January 1, 1900
Description: Replace water heaterStatus: issuedType: plumbingBusiness Name: Water Heaters NOW INCApplicant: Brandon J OverlandFees: $85Effective Date: 1900-01-01Permit Number: BLDG894157
January 1, 1900
Description: Meter move q2 - 2021 batch #17Status: issuedType: plumbingBusiness Name: Center Point Energy Resource CorpApplicant: Brandon J OverlandFees: $85Effective Date: 1900-01-01Permit Number: BLDG925076

Current Ownership

Information about the current owner(s).

Property History

5336 S Dupont Ave has undefined property events records (listings, deeds, permits, tax, foreclosure, loan).

Property Events

Environment

Environmental factors around 5336 S Dupont Ave

School Information

Public/private schools serving 5336 S Dupont Ave

Neighborhood

This property is located in Lynnhurst, Minneapolis, MN 55419.

Market Trends

Historical market data near 5336 S Dupont Ave over selected time period.

Nearby Properties on Dupont Ave