5241 S Beard Ave has 24 permit records of total value of $179,543.

Permit History
24
Permits
$179,543
Total Permit Value
July 15, 2014
Description: Wire a garageStatus: finalType: Ele exst 1 or 2 familySub Type: Residential exstBusiness Name: Carter Electric IncApplicant: Df RenovationFees: $75Effective Date: 2014-07-15Permit Number: ELE1307-03834
July 9, 2013
Description: *IRC1-R/R INSTALLATION OF BASEMENT EGRESS WINDOW & WELL TO SFD IN NEW WINDOW OPENING (DMH#2) IN EXISTING FINISHED BASEMENT FOR NEW 14' X10' BEDROOM. SEPARATE PERMITS ARE REQUIRED FOR ELECTRICAL, PLUMBING, AND HEATING/AIR CONDITIONING/VENTILATION WORK. SMOKE DETECTORS AND CARBON MONOXIDE DETECTORS SHALL BE INSTALLED AND OPERABLE AT THE TIME THE BUILDING INSPECTOR PERFORMS THE 'FINAL' INSPECTION FOR THIS PERMIT. CARBON MONOXIDE ALARMS REQUIRED IN ACCORDANCE WITH MN. STAT. 299F.50 IRC 313.2.1. When interior alterations, repairs or additions require a building permit or when one or more sleeping rooms are added or created in existing dwellings, smoke detection shall be installed: A. on each level of the house B. in each bedroom C. in the hall or room outside of bedrooms. Exceptions: 1. Smoke alarms in existing areas shall not be required to be interconnected and hardwired where the alterations or repairs do not result in the removal of interior wall or ceiling finishes exposing the structuStatus: finalType: ResidentialApplicant: Stephen CustisEffective Date: 2013-07-09Permit Number: BLDG74054
July 9, 2013
Description: *IRC1-ADD Remove roof add second floor (dmb#1) interior footings, beam, bearing wall. New stairs. Remod Kitch and bath main level. New bath and fin basement space. 2nd flr addition includes 3 bedrooms, bath. Egress windows must be increased to satisfy 5.7 sf net. North wall less than 5' to prop line so wall, soffit, fascia ratings plus 1' max overhang. SEPARATE PERMITS ARE REQUIRED FOR ELECTRICAL, PLUMBING, AND HEATING/AIR CONDITIONING/VENTILATION WORK. A SOIL EROSION CONTROL PERMIT IS REQUIRED IF MORE THAN 500 SQUARE FEET OF GROUND IS DISTURBED. APPLICANT IS RESPONSIBLE TO LOCATE AND IDENTIFY THE PROPERTY STAKES AND CALL BUILDING INSPECTOR FOR VERIFICATION INSPECTION BEFORE CONCRETE IS POURED. REFER TO THE PROPERTY LINE LOCATION BULLETIN FOR INFORMATION ON HOW TO FIND YOUR PROPERTY LINE. APPROVED PLANS AND PERMIT MUST BE ON SITE BEFORE INSPECTIONS WILL BE PROVIDED. PROTECTION OF ADJOINING PROPERTY: APPLICANT IS REQUIRED TO TAKE MEASURES TO ENSURE EXCAVATION DOES NOT CAUSE DAMAGE TO ADStatus: finalType: ResidentialApplicant: Stephen CustisEffective Date: 2013-07-09Permit Number: BLDG41974
July 3, 2013
Description: plumbing fix gas fixture replace/install - is this a new install(y/n)?__y__ - is this a replacement(y/n)?__n__ - fireplace(y/n)?__n_ - stove(y/n)?__y__ - dryer(y/n)?__y__ - water heater(y/n)?__n__ - gas grill(y/n)?__n__ - other: describe below main gas line will also be replaced carbon monoxide detectors are required in dwelling units in accordance with minnesota statute 299f.50. Please refer to the following website for additional information. Http://www.dli.mn.gov/ccld/pdf/bc_websmoke_co_06_07.pdfStatus: finalType: plumbingBusiness Name: Pronto Heating & Air Conditioning IncApplicant: Stephen CustisEffective Date: 2013-07-03Permit Number: BLDG521429
July 3, 2013
Description: plumbing fix specify the type of fixtures by entering the quantity in the list below: water closets__4__ urinals_____ bathroom tubs_2___ basins___5_ sinks___1__ wash trays__1___ showers____2_ floor drains____ extensions_____ misc fixtures___5_ electric water heaters_____ other: specify below wash box icemaker disposal dishwasher properly plug the unused plumbing openings at the nearest live main or branch on the waste and vent system. Cement is not an acceptable method of disconnect. Approved plumbing materials must be used. Dead ends are not permitted except where necessary to extend piping for a cleanout so as to be accessible. The work must be done by a licensed plumbing contractor in which a permit and inspection is required before concealing. Carbon monoxide detectors are required in dwelling units in accordance with minnesota statute 299f.50. Please refer to the following website for additional information. Http://www.dli.mn.gov/ccld/pdf/bc_websmoke_co_06_07.pdf plans approved byStatus: finalType: plumbingApplicant: Stephen CustisEffective Date: 2013-07-03Permit Number: BLDG497279
July 3, 2013
Description: plumbing fix specify the type of fixtures by entering the quantity in the list below: water closets____ urinals_____ bathroom tubs____ basins____ sinks_____ wash trays__1___ showers___1__ floor drains____ extensions_____ misc fixtures____ electric water heaters_____ other: specify below properly plug the unused plumbing openings at the nearest live main or branch on the waste and vent system. Cement is not an acceptable method of disconnect. Approved plumbing materials must be used. Dead ends are not permitted except where necessary to extend piping for a cleanout so as to be accessible. The work must be done by a licensed plumbing contractor in which a permit and inspection is required before concealing. Carbon monoxide detectors are required in dwelling units in accordance with minnesota statute 299f.50. Please refer to the following website for additional information. Http://www.dli.mn.gov/ccld/pdf/bc_websmoke_co_06_07.pdf plans approved by both the state of minnesota department of Status: finalType: plumbingApplicant: Stephen CustisEffective Date: 2013-07-03Permit Number: BLDG532029
June 19, 2013
Description: Installation of basement egress window & well to single family dwelling in new window opening (dmh#2)Job Value: $2,000Status: DoneType: RemodelingSub Type: BireBusiness Name: Jon Thoma Drywall CorporationApplicant: Stephen CustisFees: $162Effective Date: 2013-06-19Permit Number: 3085153
June 17, 2013
Description: Specify the type of fixtures by entering the quantity in the list below:Status: DoneType: plumbingSub Type: BtpaBusiness Name: Precision PlumbingApplicant: Stephen CustisFees: $84Effective Date: 2013-06-17Permit Number: 5154077
June 5, 2013
Description: | Scope of work: HVAC W/BNR - HVAC ALTERATIONS FOR INDIVIDUAL DWELLING UNIT (IF MULTI-UNIT BUILDING, IDENTIFY THE DWELLING UNIT: ____) THIS PERMIT AUTHORIZES THE FOLLOWING IDENTIFIED MECHANICAL WORK TO REPLACE AND/OR MODIFY THE EXISTING INDIVIDUAL HEATING/COOLING SYSTEM THAT SERVES AN INDIVIDUAL DWELLING UNIT. CHECK ALL THAT APPLY. __ REPLACE BOILER INCLUDING PIPING ALTERATIONS _X_ REPLACE FURNACE INCLUDING DUCT ALTERATIONS __ ADD OR REPLACE HEATER FOR SPACE HEATING __ ADD OR REPLACE AIR CONDITIONER WITH FURNACE INCLUDING DUCT ALTERATIONS**. ITEMS REQUIRED FOR INSPECTION 1. HVAC EQUIPMENT MUST BE SIZED ACCORDING TO ACCA MANUAL J OR AN EQUIVALENT METHOD. CALCULATIONS TO BE LEFT NEXT TO THE NEW APPLIANCES FOR INSPECTION. OVER SIZING OF HEATING EQUIPMENT MUST NOT EXCEED 43% AND COOLING EQUIPMENT MUST NOT EXCEED 21%. 2. ALL DOCUMENTATION RELATIVE TO MAINTENANCE AND STARTUP TESTING (ORSAT) SHALL BE AFFIXED TO THE MECHANICAL EQUIPMENT. 3. ALL WORK DONE UNDER THIS PERMIT MUST BE COMPLETED BY Status: finalType: MechanicalBusiness Name: Pronto Heating & Air Conditioning IncApplicant: Stephen CustisEffective Date: 2013-06-05Permit Number: BLDG326746
May 29, 2013
Description: MECH MECH | WARM AIR HEATING SYSTEMS | Scope of work: MOVE EXISTING FURNACE TO 2ND FLOOR AND RUN A NEW GAS LINE TO 2ND FLOOR REPLACE A/C WITH BRYANT 2 TON REPLACE 3 BATH FANS, REPLACE ALL DUCT WORK REPLACE KITCHEN RANGE HOOD Heating load calculation forms for furnaces and boilers installed in single family homes or duplexes are required to be left at the job site along with the homeowner package of information that includes the design, testing, and installation instructions. Contractors should be using manual J residential load calculations hand written or software designed. Carbon monoxide detectors are required in dwelling units in accordance with Minnesota Statute 299F.50. Please refer to the following website for additional information. http://www.dli.mn.gov/CCLD/PDF/bc_websmoke_co_06_07.pdf HVAC equipment is allowed as a permitted obstruction in a required side or rear yard as follows: Air-conditioning systems, heating, ventilating, and filtering equipment, not to exceed four (4) Status: finalType: MechanicalBusiness Name: Pronto Heating & Air Conditioning IncApplicant: Stephen CustisEffective Date: 2013-05-29Permit Number: BLDG333920
May 14, 2013
Description: Complete rewire of the house including a new serviceStatus: finalType: Ele exst 1 or 2 familySub Type: Residential exstBusiness Name: Carter Electric INCApplicant: Df RenovationFees: $140Effective Date: 2013-05-14Permit Number: ELE1302-02415
March 26, 2013
Description: Street use permit is valid for __30__ days from date of issuanceStatus: DoneType: Street use permitSub Type: BsuBusiness Name: Mac's Roll-off ServiceApplicant: Stephen CustisFees: $76Effective Date: 2013-03-26Permit Number: 1037841
February 19, 2013
Description: Move existing furnace to 2nd floor and run a new gas line to 2nd floor replace air conditioning with bryant 2 ton replace 3 bathroom fans replace all duct work replace kitchen range hoodStatus: DoneType: MechanicalSub Type: BtmaBusiness Name: Pronto Heating & Air ConditioningApplicant: Stephen CustisFees: $233Effective Date: 2013-02-19Permit Number: 4108957
February 18, 2013
Description: Gas fixture replace/installStatus: DoneType: plumbingSub Type: BtpaBusiness Name: Pronto Heating And Air ConditioningApplicant: Stephen CustisFees: $81Effective Date: 2013-02-18Permit Number: 5150004
February 1, 2013
Description: HVAC w/bnr - HVAC alterations for individual dwelling unitStatus: DoneType: HVAC alterationsSub Type: BtmbBusiness Name: Pronto Heating & Air ConditioningApplicant: Stephen CustisFees: $125Effective Date: 2013-02-01Permit Number: 4101941
January 30, 2013
Description: Specify the type of fixtures by entering the quantity in the list below:Status: DoneType: plumbingSub Type: BtpaBusiness Name: Precision PlumbingApplicant: Stephen CustisFees: $821Effective Date: 2013-01-30Permit Number: 5149504
December 31, 2012
Description: Remove roof addition second floor (dmb#1) interior footings beam bearing wall. New stairs. Remod kitch and bathroom main level. New bathroom and fin basement space. 2nd floor addition includes 3 bedrooms bathroom. Egress windows must be increased to satisfy 5.7 sf net. North wall less than 5 to prop line so wall soffit fascia ratings plus 1 max overhangJob Value: $141,740Status: DoneType: RemodelingSub Type: BireBusiness Name: Jon Thoma Drywall CorporationApplicant: Stephen CustisFees: $2,809Effective Date: 2012-12-31Permit Number: 3082455
December 7, 2012
Description: Construct detached _24'__ by __20'_ wood frame garage at the rear single family dwelling (maa #02)Job Value: $16,000Status: OpenType: RemodelingSub Type: BireBusiness Name: Jon Thoma Drywall CorporationApplicant: Stephen CustisFees: $363Effective Date: 2012-12-07Permit Number: 3082206
October 8, 1997
Description: Rpr layover existing roof residenceJob Value: $3,198Status: DoneType: BuildingSub Type: BApplicant: Stephen Custis0Effective Date: 1997-10-08Permit Number: 648006
October 6, 1997
Description: Instl 2-30a ckt furnace & air conditioning residenceJob Value: $145Status: DoneType: ElectricalSub Type: FApplicant: Stephen Custis0Effective Date: 1997-10-06Permit Number: 908723
September 23, 1997
Description: Instl, air conditioning, pw, pa, 1at66gas-br l&m=td p=rhStatus: DoneType: Gas burnerSub Type: QmApplicant: Stephen Custis0Effective Date: 1997-09-23Permit Number: 110631
March 24, 1997
Description: Instl gw residenceJob Value: $400Status: DoneType: plumbingSub Type: DApplicant: Stephen Custis0Effective Date: 1997-03-24Permit Number: 948126
January 1, 1994
Description: Instl saver switch on air conditioning residenceJob Value: $60Status: DoneType: ElectricalSub Type: FApplicant: Stephen Custis0Effective Date: 1994-01-01Permit Number: 871955
January 1, 1900
Description: *irc4-newJob Value: $16,000Status: completeType: ResidentialBusiness Name: JON Thoma Drywall CorpApplicant: Stephen CustisEffective Date: 1900-01-01Permit Number: BLDG56530

Current Ownership

Information about the current owner(s).

Property History

5241 S Beard Ave has undefined property events records (listings, deeds, permits, tax, foreclosure, loan).

Property Events

Environment

Environmental factors around 5241 S Beard Ave

School Information

Public/private schools serving 5241 S Beard Ave

Neighborhood

This property is located in Fulton, Minneapolis, MN 55410.

Market Trends

Historical market data near 5241 S Beard Ave over selected time period.

Nearby Properties on Beard Ave