?
  • Chat with Us
  • Submit Feedback
  • TopHap Academy
  • What's New?
Residential > House
Sold
08/19/2016
Sold Price
$650,000$300/ft²

5117 S Chowen Ave
Minneapolis, MN 55410

5117 S Chowen Ave, Minneapolis, MN 55410 is a 4 bed, 4 bath, 2,170 ft² house built in 1927 on a 0.130 acre lot with 27 construction permits. This house is currently off market, and it was last sold in 2016 for $650,000. The latest TopHap estimate of the house's value is $838,931.

Property Valuations

Latest estimates for 5117 S Chowen Ave based on TopHap automated valuation model (AVM).

Permits

5117 S Chowen Ave has 27 permit records of total value of $212,850.

Permit History
27
Permits
$212,850
Total Permit Value
March 12, 2019
Description: Gas to dryer and fireplaceStatus: completeType: plumbingBusiness Name: Creative Heating & AIR Conditioning LLCApplicant: Sean Van Den HeuvelFees: $142Effective Date: 2019-03-12Permit Number: BLDG667989
July 19, 2016
Description: *IRC1-ADD CONSTRUCT 2ND FLOOR ADDITION WITH ATTACHED GARAGE TO EXISTING SINGLE FAMILY HOUSE. AAJ#1. ***08/13/2015 - REVISION TO EXISTING SCOPE OF WORK DUE TO MODIFICATION WORK DONE ON SITE - AAJ#1*** - REVISION TO WINDOWS AND DOORS AS NOTED ON REVISED CONSTRUCTION PLANS. - INSTALL NEW CANTILEVER FLOOR ON SOUTH ELEVATION WALL AS NOTED ON FLOOR PLAN. - PARTIAL INTERIOR MODIFICATION ON BASEMENT, MAIN AND 2ND FLOOR AS NOTE DON REVISED FLOOR PLAN. - REMOVE TWO SIDED FIRE PLACES AND ***SEE REVISED CONSTRUCTION PLANS FOR DETAIL SCOPE OF WORK TO BE DONE. PER APPLICANT, THERE IS NO CHANGE TO ESTIMATED PROJECT VALUE*** ***NOTE: PROVIDE ONE HOURE FIRE WALL, OPENINGS AND ROOF EAVE ON NORTH ELEVATION WALL WITH LESS THAN 5'0" SETBACK FROM PROPERTY LINE PER 2015 MINNESOTA RESIDENTIAL CODE, SECTION R302.1 AND TABLE R302.1*** DEMOLITION: - REMOVE EXISTING HOUSE ROOF TO ALLOW FOR NEW 2ND FLOOR ADDITION. - INTERIOR DEMOLITION OF EXISTING BASEMENT AND MAIN FLOOR TO ALLOW FOR NEW RENOVATION WORK TO BE DONEStatus: finalType: ResidentialApplicant: Sean Van Den HeuvelEffective Date: 2016-07-19Permit Number: BLDG59055
July 14, 2016
Description: PLUMB MOVE METER FROM INSIDE TO OUTSIDE Properly plug the unused plumbing openings at the nearest live main or branch on the waste and vent system. Cement is not an acceptable method of disconnect. Approved plumbing materials must be used. Dead ends are not permitted except where necessary to extend piping for a cleanout so as to be accessible. The work must be done by a licensed plumbing contractor in which a permit and inspection is required before concealing. Carbon monoxide detectors are required in dwelling units in accordance with Minnesota Statute 299F.50. Please refer to the following website for additional information. http://www.dli.mn.gov/CCLD/PDF/bc_websmoke_co_06_07.pdf Plans approved by both the State of Minnesota Department of Health and the Department of Labor and Industry are required to be on site for all plumbing work conducted in hospitals, nursing homes, supervised living facilities, outpatient surgical centers, boarding care homes, and residential hospice facilitiStatus: finalType: PlumbingBusiness Name: Centerpoint EnergyApplicant: Sean Van Den HeuvelEffective Date: 2016-07-14Permit Number: BLDG544375
July 6, 2016
Description: HVAC-LVL3 | Scope of work: HVAC WORK AND ENTIRE SYSTEM REPLACEMENT ** NO NEW CONSTRUCTION - Tear-downs and major remodels are considered new construction ** Identify number of each of the existing individual heating/cooling system being replaced, that serves an individual dwelling unit. Indicate the number of systems that apply: __Remove existing system and install new (boiler or forced air system) _X_Install a new system to serve an existing non-conditioned space (FURNACE GMH95070, AIR COND SSX13024, 4 BATH FANS, 1 DRYER, 1 KITCHEN HOOD AND ALL NEW DUCTWORK) REQUIRED FOR INSPECTION 1. HVAC equipment must be sized to ACCA manual J or an equivalent method. Heat loss calculations to be left next to appliances for inspection. Over-sizing of heating equipment must not exceed 43% and cooling equipment must not exceed 21%. 2. Documents relative to maintenance and startup testing (orsat) shall be affixed to the mechanical equipment. 3. All work done under this permit must be completed by a peStatus: finalType: MechanicalBusiness Name: Creative Heating & Air Conditioning LlcApplicant: Sean Van Den HeuvelEffective Date: 2016-07-06Permit Number: BLDG368304
January 29, 2016
Description: Move meter from inside to outsideStatus: OpenType: plumbingSub Type: BtpaBusiness Name: Centerpoint Energy Minnesota GasApplicant: Genesis Renovations Lnd HldgFees: $82Effective Date: 2016-01-29Permit Number: 5189554
December 22, 2015
Description: RFS Number: 15-1119154Status: finalType: ErosionApplicant: Sean Van Den HeuvelEffective Date: 2015-12-22Permit Number: BLDG620470
October 20, 2015
Description: GAS FIX Gas fixture replace/install - Is this a new install(y/n)?____ - Is this a replacement(y/n)?____ - Fireplace(y/n)?_Y__ - Stove(y/n)?___Y_ - Dryer(y/n)?__Y__ - Water Heater(y/n)?____ - Gas grill(y/n)?____ - Other: describe below Carbon monoxide detectors are required in dwelling units in accordance with Minnesota Statute 299F.50. Please refer to the following website for additional information. http://www.dli.mn.gov/ccld/PDF/bc_websmoke_co_06_07.pdfStatus: finalType: PlumbingBusiness Name: Creative Heating & Air Conditioning LlcApplicant: Sean Van Den HeuvelEffective Date: 2015-10-20Permit Number: BLDG520084
October 20, 2015
Description: PLUM FIX Remodel home. Installation of 4 finished bathrooms, kitchen with dishwasher, washer box, floor drain, water heater, water supplies and DWV for all fixtures. Lift station (if applicable) _______________________________________ Specify the type of fixtures by entering the quantity in the list below: Water Closets____ Urinals_____ Bath Tubs____ Basins____ Sinks_____ Wash Trays_____ Showers_____ Floor Drains____ Extensions_____ Misc Fixtures____ Electric Water Heaters_____ Other: Specify below Properly plug the unused plumbing openings at the nearest live main or branch on the waste and vent system. Cement is not an acceptable method of disconnect. Approved plumbing materials must be used. Dead ends are not permitted except where necessary to extend piping for a cleanout so as to be accessible. The work must be done by a licensed plumbing contractor in which a permit and inspection is required before concealing. Carbon monoxide detectors are required in dwelling units in accordancStatus: finalType: PlumbingApplicant: Sean Van Den HeuvelEffective Date: 2015-10-20Permit Number: BLDG539317
October 20, 2015
Description: GAS FIX Gas fixture replace/install - Is this a new install(y/n)?____ - Is this a replacement(y/n)?____ - Fireplace(y/n)?_24,000 - Stove(y/n)?____ - Dryer(y/n)?____ - Water Heater(y/n)?____ - Gas grill(y/n)?____ - Other: describe below Carbon monoxide detectors are required in dwelling units in accordance with Minnesota Statute 299F.50. Please refer to the following website for additional information. http://www.dli.mn.gov/ccld/PDF/bc_websmoke_co_06_07.pdfStatus: finalType: PlumbingBusiness Name: Daves Heating Air Con & ElectricApplicant: Sean Van Den HeuvelEffective Date: 2015-10-20Permit Number: BLDG596682
September 3, 2015
Description: Dumpster in streetStatus: OpenType: Street use permitSub Type: BsuBusiness Name: Elite Waste DisposalApplicant: Genesis Renovations Lnd HldgFees: $81Effective Date: 2015-09-03Permit Number: 1046409
August 13, 2015
Description: Gas fixture replace/installStatus: OpenType: plumbingSub Type: BtpaBusiness Name: Daves Heating Air Con & ElectricApplicant: Genesis Renovations Lnd HldgFees: $82Effective Date: 2015-08-13Permit Number: 5182704
August 12, 2015
Description: 5117 chowenStatus: ISSUEDType: Ele new 1 or 2 familyBusiness Name: COMMON GROUND ELECTRIC LLCApplicant: Genisis RemodelingFees: $101Effective Date: 2015-08-12Permit Number: ELE1508-03426
August 3, 2015
Description: Gas fixture replace/installStatus: OpenType: plumbingSub Type: BtpaBusiness Name: Creative Heating & Air ConditioningApplicant: Genesis Renovations Lnd HldgFees: $212Effective Date: 2015-08-03Permit Number: 5182380
August 3, 2015
Description: HVAC work and entire system replacementStatus: OpenType: HVAC alterationsSub Type: BtmbBusiness Name: Creative Heating & Air ConditioningApplicant: Genesis Renovations Lnd HldgFees: $209Effective Date: 2015-08-03Permit Number: 4113989
July 23, 2015
Description: Street use permit is valid for __30__ days from date of issuanceStatus: DoneType: Street use permitSub Type: BsuBusiness Name: Elite Waste DisposalApplicant: Genesis Renovations Lnd HldgFees: $162Effective Date: 2015-07-23Permit Number: 1045822
June 12, 2015
Status: OpenType: Env. Soil erosion permitSub Type: BeseBusiness Name: Genesis Remodeling LlcApplicant: Genesis Renovations Lnd HldgFees: $124Effective Date: 2015-06-12Permit Number: 1007435
June 12, 2015
Description: Construct 2nd floor addition with attached garage to existing single family house. Aaj#1Job Value: $200,000Status: OpenType: RemodelingSub Type: BireBusiness Name: Genesis Remodeling LlcApplicant: Genesis Renovations Lnd HldgFees: $3,704Effective Date: 2015-06-12Permit Number: 3098463
May 30, 2015
Project Name: Chowen 5117Description: Temporary serviceStatus: finalType: Ele new 1 or 2 familyBusiness Name: Common Ground Electric LLCApplicant: Genisis RemodelingFees: $52Effective Date: 2015-05-30Permit Number: ELE1505-07039
May 18, 2015
Description: Remodel home. Installation of 4 finished bathrooms kitchen with dishwasher washer box floor drain water heater water supplies and dwv for all fixtures. Lift station (if applicable)Status: OpenType: plumbingSub Type: BtpaBusiness Name: Accurate PlumbingApplicant: Genesis Renovations Lnd HldgFees: $792Effective Date: 2015-05-18Permit Number: 5179796
April 29, 2015
Project Name: Chowen TempDescription: Temporary service for new homeStatus: finalType: Ele new 1 or 2 familyBusiness Name: Common Ground Electric LLCApplicant: Genisis RemodelingFees: $52Effective Date: 2015-04-29Permit Number: ELE1504-06103
May 27, 2009
Description: ROOF TO Remove existing roof material and replace with new - House (Y/N)?__Y___ - Garage(Y/N)?_____ - Will ventilation be added (Y/N)?____ - Will roof sheathing be repaired/replaced (Y/N)?____ - Other: describe below M.C.O. 89.165 Completion of work - All work for altering, repairing, or remodeling the exterior portion of a single-family dwelling or two-family dwelling, including an attached or detached garage, shall be completed within one 1) year from the date of issuance of the building permit.Status: finalType: ResidentialApplicant: Sean Van Den HeuvelEffective Date: 2009-05-27Permit Number: BLDG111345
May 7, 2009
Description: Dumpster must have the company name and telephone number on the container in legible printing in a conspicuous placeStatus: DoneType: Street use permitSub Type: BsuBusiness Name: Keith Krupenny & Son Disposal ServiceApplicant: Sonja R OrtizFees: $70Effective Date: 2009-05-07Permit Number: 1025537
March 31, 2009
Description: Remove existing roof material and replace with newStatus: DoneType: Building over the counterSub Type: BotcBusiness Name: Austad Construction IncApplicant: Sonja R OrtizFees: $136Effective Date: 2009-03-31Permit Number: 1078401
September 20, 2006
Description: DET GAR Construct detached _14__ by _20__ wood frame garage. (JSE#2) GENERAL COMMENTS: APPLICANT MUST LOCATE AND IDENTIFY THE PROPERTY STAKES AND CALL FOR INSPECTION FOR BUILDING INSPECTOR VERIFICATION BEFORE CONCRETE IS POURED. APPROVED SITE PLAN AND PERMIT MUST BE ON SITE BEFORE INSPECTIONS WILL BE PROVIDED. SEPARATE ELECTRICAL AND MECHANICAL PERMITS REQUIRED FOR ELECTRICAL AND MECHANICAL WORK. Walls, soffits, and fascia closer than 3 feet to property lines not adjacent to public right-of-ways must be protected on the interior and exterior face with 5/8" exterior gypsum sheathing, stucco or other approved materials for fire resistance. Openings (windows, etc.) are not permitted in walls closer than 3 feet to property lines not adjacent to public right-of-ways. 12 ft. maximum average roof height Eaves are not permitted to extend closer than 6 in. to property line Anchor bolts must be within 12 in. of each end of each piece of plate and 6 ft. on center maximum Truss diagrams must be avStatus: finalType: ResidentialApplicant: Sean Van Den HeuvelEffective Date: 2006-09-20Permit Number: BLDG27637
August 8, 2006
Description: Construct detached _14__ by _20__ wood frame garage. (jse#2)Job Value: $9,430Status: DoneType: RemodelingSub Type: BireBusiness Name: First Landmark Builders IncApplicant: Sonja R OrtizFees: $209Effective Date: 2006-08-08Permit Number: 3042947
October 10, 2000
Status: finalType: ResidentialApplicant: Sean Van Den HeuvelEffective Date: 2000-10-10Permit Number: BLDG192421
July 25, 2000
Job Value: $3,420Status: DoneType: Building over the counterSub Type: BotcBusiness Name: Peter Hall Const IncApplicant: Sonja R OrtizFees: $89Effective Date: 2000-07-25Permit Number: 1026719

Current Ownership

Information about the current owner(s).

Property History

5117 S Chowen Ave has undefined property events records (listings, deeds, permits, tax, foreclosure, loan).

Property Events

Environment

Environmental factors around 5117 S Chowen Ave

School Information

Public/private schools serving 5117 S Chowen Ave

Neighborhood

This property is located in Fulton, Minneapolis, MN 55410.

Market Trends

Historical market data near 5117 S Chowen Ave over selected time period.

Nearby Properties on Chowen Ave