  • Chat with Us
  • Submit Feedback
  • TopHap Academy
  • What's New?
Commercial > Multi-family / Apartments
Off-Market
Sold Price
$--$--/ft²

4900 Chicago Ave
Minneapolis, MN 55417

4900 Chicago Ave, Minneapolis, MN 55417 is a 6,948 ft² multi-family/apartments property built in 1950 on a 0.220 acre lot with 19 construction permits. This multi-family/apartments is currently off market.

Permits

4900 Chicago Ave has 19 permit records of total value of $151,190.

Permit History
19
Permits
$151,190
Total Permit Value
July 19, 2017
Description: MECH MECH | Scope of work: REPLACE EXISTING BOILERS 2 @ 228MBH -removal or replacement of existing backflow or RPZ devices must be done on a separate plumbing permit on commercial boiler replacements Heating load calculation forms for furnaces and boilers installed in single family homes or duplexes are required to be left at the job site along with the homeowner package of information that includes the design, testing, and installation instructions. Contractors should be using manual J residential load calculations hand written or software designed. Carbon monoxide detectors are required in dwelling units in accordance with Minnesota Statute 299F.50. Please refer to the following website for additional information. http://www.dli.mn.gov/CCLD/PDF/bc_websmoke_co_06_07.pdf HVAC equipment is allowed as a permitted obstruction in a required side or rear yard as follows: Air-conditioning systems, heating, ventilating, and filtering equipment, not to exceed four (4) feet in height and adjaceStatus: finalType: MechanicalApplicant: P B CrockettEffective Date: 2017-07-19Permit Number: BLDG333211
January 28, 2016
Description: Rpz test sn: 519984 date; 1/26/16Status: DoneType: plumbing rpzSub Type: BtpbBusiness Name: Blaylock PlumbingApplicant: Paul & Georgia CrockettFees: $41Effective Date: 2016-01-28Permit Number: 1047820
February 3, 2015
Description: *R2-5+R/R TEAR-OFF AND REPLACE PITCHED ROOF All roof drains, area drains, or other stormwater or clearwater connections to the City's sanitary sewer system must be disconnected per Chapter 56 of the Minneapolis Code of Ordinances. Contact Arvella Greenway at 612 673 5899 if you questions.Status: finalType: CommercialApplicant: P B CrockettEffective Date: 2015-02-03Permit Number: BLDG253736
November 10, 2014
Description: Rpz test sn: 519984 date: 10/30/14Status: DoneType: plumbing rpzSub Type: BtpbBusiness Name: Raymond E Haeg PlumbingApplicant: Paul & Georgia CrockettFees: $45Effective Date: 2014-11-10Permit Number: 1044907
October 30, 2013
Description: plumbing rpz install sn: 519984 date: 10/10/13 make: apollo model: rplf4a size: 1/2 system; boiler make up location ; boiler rm-1st fl (rpz rep0rt received 10/16/13) >>>>>>>>>>>call plumbing inspector on page 2 for install inspectionStatus: finalType: plumbingApplicant: P B CrockettEffective Date: 2013-10-30Permit Number: BLDG505319
October 18, 2013
Status: DoneType: plumbingSub Type: BtpaBusiness Name: Seitz Bros IncApplicant: Paul & Georgia CrockettFees: $84Effective Date: 2013-10-18Permit Number: 5158004
September 27, 2013
Description: Street use permit is valid for _30___ days from date of issuanceStatus: DoneType: Street use permitSub Type: BsuBusiness Name: PodsApplicant: Paul & Georgia CrockettFees: $78Effective Date: 2013-09-27Permit Number: 1039800
September 5, 2013
Description: Wire (2) boilersStatus: finalType: Ele non dwellingSub Type: AgriculturalBusiness Name: Xtreme Electrical Services INCFees: $40Effective Date: 2013-09-05Permit Number: ELE1308-04956
August 1, 2013
Description: Replace existing boilers 2 @ 228mbhJob Value: $10,000Status: OpenType: MechanicalSub Type: BtmaBusiness Name: Nordic ServicesApplicant: Paul & Georgia CrockettFees: $464Effective Date: 2013-08-01Permit Number: 4110103
April 27, 2012
Description: Tear-off and replace pitched roofJob Value: $15,000Status: OpenType: RemodelingSub Type: BireBusiness Name: Bulldog Contractors LlcApplicant: Paul & Georgia CrockettFees: $344Effective Date: 2012-04-27Permit Number: 3077844
October 2, 2009
Description: KIVA Permit Type: BETP KIVA Permit number: 1000714 KIVA Permit Name: UST REMOVAL, APARTMENT -- -- ENVMGMT -- This permit is for the removal of one 1,000 gallon underground storage tank used for heating fuel oil. This work is scheduled for Thursday, July 23rd 2009 If this job is rescheduled contact Tom Frame at 612-673-5807. Copies of soil analytical results should be sent to: Thomas Frame Minneapolis Environmental Services 250 South 4th Street, RM 414 Minneapolis, MN 55415 tom.frame@ci.minneapolis.mn.us fax: 612-673-2635 Heating Inspection Requirements for fuel oil tanks and associated piping: Application must be submitted to Minneapolis Development Review for permit issuance. Inspection must be scheduled for tank tightness and line tightness testing with the assigned area inspector. Inspection must occur prior to burial for underground tanks and piping. For further information contact Minneapolis Information and Services at 311 or outside Minneapolis (612) 673-3000. CHAPTER 48. MINNEAStatus: finalType: TankApplicant: P B CrockettEffective Date: 2009-10-02Permit Number: BLDG641699
July 21, 2009
Description: This permit is for the removal of one 1, 000 gallon underground storage tank used for heating fuel oilStatus: DoneType: Env. Tank permitSub Type: BetpBusiness Name: Mtm EnvironmentalApplicant: Paul & Georgia CrockettFees: $134Effective Date: 2009-07-21Permit Number: 1000714
August 15, 2005
Description: MECH MECH | WARM AIR HEATING SYSTEMS | Scope of work: INSTALL FRESH AIR INTAKE (MAC SOUND PROJECT). MAC 105-05 MECH | Scope of work: INSTALL FRESH AIR INTAKE (MAC SOUND PROJECT). MAC 105-05 MECH | Scope of work: INSTALL FRESH AIR INTAKE (MAC SOUND PROJECT). MAC 105-05 MECH | Scope of work: INSTALL FRESH AIR INTAKE (MAC SOUND PROJECT). MAC 105-05Status: finalType: MechanicalBusiness Name: Erickson Plbg Htg Ac IncApplicant: P B Crockett0Effective Date: 2005-08-15Permit Number: BLDG280716
August 5, 2005
Description: R1/r2/rem alts for sound control metropolitan airport commission job 106-6-306Status: finalType: ResidentialApplicant: P B CrockettEffective Date: 2005-08-05Permit Number: BLDG93434
April 21, 2005
Description: Wire motorized freshair intake install exhaust fans outlets for a/c'sStatus: DoneType: ElectricalSub Type: BteaBusiness Name: Erickson Plbg, Htg & CoolingApplicant: Paul & Georgia CrockettFees: $170Effective Date: 2005-04-21Permit Number: 1079294
April 19, 2005
Description: Install fresh air intake (mac sound project)Job Value: $1,000Status: DoneType: MechanicalSub Type: BtmaBusiness Name: Erickson Plbg Htg Ac IncApplicant: Paul & Georgia CrockettFees: $60Effective Date: 2005-04-19Permit Number: 4051772
March 7, 2005
Description: Alts for sound control metropolitan airport commission job 106-6-306Job Value: $104,590Status: DoneType: Building over the counterSub Type: BotcBusiness Name: Crossroad Construction IncApplicant: Paul & Georgia CrockettFees: $1,139Effective Date: 2005-03-07Permit Number: 1058971
July 15, 1996
Description: Rpl reroof w/tearoff (premier properties) comrclJob Value: $2,600Status: DoneType: BuildingSub Type: BApplicant: Paul & Georgia Crockett0Effective Date: 1996-07-15Permit Number: 631383
July 10, 1996
Description: Rpl windows w/same size as exist 10-unit dwlgJob Value: $18,000Status: DoneType: BuildingSub Type: BApplicant: Paul & Georgia Crockett0Effective Date: 1996-07-10Permit Number: 631189

Current Ownership

Information about the current owner(s).

Property History

4900 Chicago Ave has undefined property events records (listings, deeds, permits, tax, foreclosure, loan).

Property Events

Environment

Environmental factors around 4900 Chicago Ave

School Information

Public/private schools serving 4900 Chicago Ave

Neighborhood

This property is located in Field, Minneapolis, MN 55417.

Market Trends

Historical market data near 4900 Chicago Ave over selected time period.

Nearby Properties on Chicago Ave