  • Chat with Us
  • Submit Feedback
  • TopHap Academy
  • What's New?
Residential > House
Sold
07/24/2012
Sold Price
$--$--/ft²

4733 S 30th Ave
Minneapolis, MN 55406

4733 S 30th Ave, Minneapolis, MN 55406 is a 3 bed, 3 bath, 1,440 ft² house built in 1925 on a 0.120 acre lot with 14 construction permits. This house is currently off market, and it was last sold in 2012. The latest TopHap estimate of the house's value is $629,693.

Property Valuations

Latest estimates for 4733 S 30th Ave based on TopHap automated valuation model (AVM).

Permits

4733 S 30th Ave has 14 permit records of total value of $335,950.

Permit History
14
Permits
$335,950
Total Permit Value
September 27, 2017
Description: Run high pressure gas line from new meter location to basement bedroom closed. Building gas tgree and connect to existing low pressure gas line. Run new gas line to grill. Install new shut off valve in mechanical room and at grillStatus: completeType: plumbingBusiness Name: Practical SystemsApplicant: Seth BerlinFees: $82Effective Date: 2017-09-27Permit Number: BLDG672386
June 8, 2016
Description: *IRC1-R/R 13' x 14'-10" DOUBLE STORY REAR ADDITION INCLUDING BASEMENT AT SFD (MAA #02) ENGINEER OF RECORD RICHARD W JOHNSON MN REG# 23406 SEPARATE PERMITS ARE REQUIRED FOR ELECTRICAL, PLUMBING, AND HEATING/AIR CONDITIONING/VENTILATION WORK. CARBON MONOXIDE ALARMS REQUIRED IN ACCORDANCE WITH MN. STAT. 299F.50 IRC 313.2.1. When interior alterations, repairs or additions require a building permit or when one or more sleeping rooms are added or created in existing dwellings, smoke detection shall be installed: A. on each level of the house B. in each bedroom C. in the hall or room outside of bedrooms. Exceptions: 1. Smoke alarms in existing areas shall not be required to be interconnected and hardwired where the alterations or repairs do not result in the removal of interior wall or ceiling finishes exposing the structure, unless there is a crawl space or basement available which could provide access for hardwiring and interconnection without the removal of interior finishes. 2. Work on thJob Value: $167,975Status: completeType: ResidentialBusiness Name: Restoration & RenovationsApplicant: Seth BerlinEffective Date: 2016-06-08Permit Number: BLDG40037
June 8, 2016
Description: plumbing fix specify the type of fixtures by entering the quantity in the list below: water closets_3___ urinals_____ bathroom tubs_1___ basins_4___ sinks_1____ wash trays__1___ showers__1___ floor drains_1___ extensions_____ misc fixtures_4___ electric water heaters_____ other: specify below. 1 disposal 1 dishwasher 2 hose bibs 1 gas water heater properly plug the unused plumbing openings at the nearest live main or branch on the waste and vent system. Cement is not an acceptable method of disconnect. Approved plumbing materials must be used. Dead ends are not permitted except where necessary to extend piping for a cleanout so as to be accessible. The work must be done by a licensed plumbing contractor in which a permit and inspection is required before concealing. Carbon monoxide detectors are required in dwelling units in accordance with minnesota statute 299f.50. Please refer to the following website for additional information. Http://www.dli.mn.gov/ccld/pdf/bc_websmoke_co_06_07.pdStatus: finalType: plumbingApplicant: Seth BerlinEffective Date: 2016-06-08Permit Number: BLDG496833
May 21, 2014
Description: MECH MECH | Scope of work: Addition duct work, 2 bath fans, range hood - under 300 cfm Heating load calculation forms for furnaces and boilers installed in single family homes or duplexes are required to be left at the job site along with the homeowner package of information that includes the design, testing, and installation instructions. Contractors should be using manual J residential load calculations hand written or software designed. Carbon monoxide detectors are required in dwelling units in accordance with Minnesota Statute 299F.50. Please refer to the following website for additional information. http://www.dli.mn.gov/CCLD/PDF/bc_websmoke_co_06_07.pdf HVAC equipment is allowed as a permitted obstruction in a required side or rear yard as follows: Air-conditioning systems, heating, ventilating, and filtering equipment, not to exceed four (4) feet in height and adjacent to a nonresidential use or adjacent to a residential use which is equipped with central air conditioning or whStatus: finalType: MechanicalApplicant: Seth BerlinEffective Date: 2014-05-21Permit Number: BLDG363767
March 1, 2013
Description: RemodelStatus: finalType: Ele exst 1 or 2 familySub Type: Residential exstBusiness Name: Mowry Electric INCApplicant: Bill StephensonFees: $75Effective Date: 2013-03-01Permit Number: ELE1211-08570
March 1, 2013
Description: AdditionStatus: finalType: Ele exst 1 or 2 familySub Type: Residential exstBusiness Name: Mowry Electric INCApplicant: Bill StevensonFees: $100Effective Date: 2013-03-01Permit Number: ELE1211-06657
November 28, 2012
Description: Remodel additionStatus: rejectedType: Ele exst 1 or 2 familySub Type: Residential exstBusiness Name: Mowry Electric INCEffective Date: 2012-11-28Permit Number: ELE1211-08569
November 27, 2012
Description: Addition duct work 2 bathroom fans range hood - under 300 cfmStatus: DoneType: MechanicalSub Type: BtmaBusiness Name: Aabbott Ferraro Htg & CoolApplicant: Hillel S BerlinFees: $77Effective Date: 2012-11-27Permit Number: 4108292
November 14, 2012
Description: Street use permit is valid for _30___ days from date of issuanceStatus: DoneType: Street use permitSub Type: BsuBusiness Name: Atomic RecyclingApplicant: Hillel S BerlinFees: $76Effective Date: 2012-11-14Permit Number: 1037069
November 10, 2012
Description: Specify the type of fixtures by entering the quantity in the list below:Status: OpenType: plumbingSub Type: BtpaBusiness Name: Jessica OsteboApplicant: Hillel S BerlinFees: $671Effective Date: 2012-11-10Permit Number: 5145713
October 12, 2012
Description: Street use permit is valid for _30___ days from date of issuanceStatus: DoneType: Street use permitSub Type: BsuBusiness Name: Atomic RecyclingApplicant: Hillel S BerlinFees: $76Effective Date: 2012-10-12Permit Number: 1036781
October 4, 2012
Description: 13 x 14'-10 double story rear addition including basement at single family dwelling (maa #02)Job Value: $167,975Status: OpenType: RemodelingSub Type: BireBusiness Name: Restorations And RenovationsApplicant: Hillel S BerlinFees: $3,148Effective Date: 2012-10-04Permit Number: 3081124
April 7, 2011
Description: MECH MECH | Scope of work: FURNACE HEAT LOSS ATTACHED 70,000 BTUS Carbon monoxide detectors are required in dwelling units in accordance with Minnesota Statute 299F.50. Please refer to the following website for additional information. http://www.doli.state.mn.us/pdf/bcs_co_detectors_joint_memo_july06.pdf HVAC equipment is allowed as a permitted obstruction in a required side or rear yard as follows: Air-conditioning systems, heating, ventilating, and filtering equipment, not to exceed four (4) feet in height and adjacent to a nonresidential use or adjacent to a residential use which is equipped with central air conditioning or which has no windows or doors in the wall immediately abutting the yard. Such equipment may project into a corner side yard, provided such equipment is located no closer than three (3) feet from the corner side lot line. In no case shall any permitted obstruction be located closer than one (1) foot from the property line. If you have any questions, please call 31Status: completeType: MechanicalBusiness Name: Bonfe's Plbg & Heating IncApplicant: Seth BerlinEffective Date: 2011-04-07Permit Number: BLDG326211
November 19, 2010
Description: Furnace heat loss attached 70, 000 btusStatus: DoneType: MechanicalSub Type: BtmaBusiness Name: Bonfe's Plbg & Heating, IncApplicant: Hillel S BerlinFees: $105Effective Date: 2010-11-19Permit Number: 4095219

Current Ownership

Information about the current owner(s).

Property History

4733 S 30th Ave has undefined property events records (listings, deeds, permits, tax, foreclosure, loan).

Property Events

Environment

Environmental factors around 4733 S 30th Ave

School Information

Public/private schools serving 4733 S 30th Ave

Neighborhood

This property is located in Ericsson, Minneapolis, MN 55406.

Market Trends

Historical market data near 4733 S 30th Ave over selected time period.

Nearby Properties on 30th Ave