  • Chat with Us
  • Submit Feedback
  • TopHap Academy
  • What's New?
Residential > House
Off-Market
Sold Price
$--$--/ft²

411 N 26th Ave
Minneapolis, MN 55411

411 N 26th Ave, Minneapolis, MN 55411 is a 2 bed, 2 bath, 960 ft² house built in 1900 on a 0.040 acre lot with 19 construction permits. This house is currently off market. The latest TopHap estimate of the house's value is $152,750.

Property Valuations

Latest estimates for 411 N 26th Ave based on TopHap automated valuation model (AVM).

Permits

411 N 26th Ave has 19 permit records of total value of $31,995.

Permit History
19
Permits
$31,995
Total Permit Value
October 9, 2019
Description: Replacing 1200 of under ground electrical cable to existing poleStatus: issuedType: UtilityBusiness Name: XcelApplicant: Conor M ObrienEffective Date: 2019-10-09Permit Number: BLDG798151
October 8, 2019
Description: Replacing 130 of under ground electrical cable to existing transformerStatus: issuedType: UtilityBusiness Name: XcelApplicant: Conor M ObrienEffective Date: 2019-10-08Permit Number: BLDG797905
February 9, 2015
Description: GAS FIX Gas fixture replace/install - Is this a new install(y/n)?____ - Is this a replacement(y/n)?____ - Fireplace(y/n)?___ - Stove(y/n)?____ - Dryer(y/n)?__Y__ CONNECT GAS DRYER TO GAS LINE - 20,000 BTU'S - Water Heater(y/n)?____ - Gas grill(y/n)?____ - Other: describe below Carbon monoxide detectors are required in dwelling units in accordance with Minnesota Statute 299F.50. Please refer to the following website for additional information. http://www.dli.mn.gov/ccld/PDF/bc_websmoke_co_06_07.pdfStatus: finalType: PlumbingApplicant: Conor M ObrienEffective Date: 2015-02-09Permit Number: BLDG570774
December 15, 2014
Description: Gas fixture replace/installStatus: OpenType: plumbingSub Type: BtpaBusiness Name: Conor M ObrienApplicant: Robin O'brienFees: $86Effective Date: 2014-12-15Permit Number: 5172737
September 18, 2014
Description: Gas fixture replace/installStatus: DoneType: plumbingSub Type: BtpaBusiness Name: Barr Web Industries, IncApplicant: Robin O'brienFees: $86Effective Date: 2014-09-18Permit Number: 5170067
August 25, 2014
Description: *IRC1-R/R KITCHEN AND BATHROOM REMODEL AND 9 NEW WINDOWS AT SFD (WSS) SEPARATE PERMITS ARE REQUIRED FOR ELECTRICAL, PLUMBING, AND HEATING/AIR CONDITIONING/VENTILATION WORK. CARBON MONOXIDE ALARMS REQUIRED IN ACCORDANCE WITH MN. STAT. 299F.50 IRC 313.2.1. When interior alterations, repairs or additions require a building permit or when one or more sleeping rooms are added or created in existing dwellings, smoke detection shall be installed: A. on each level of the house B. in each bedroom C. in the hall or room outside of bedrooms. Exceptions: 1. Smoke alarms in existing areas shall not be required to be interconnected and hardwired where the alterations or repairs do not result in the removal of interior wall or ceiling finishes exposing the structure, unless there is a crawl space or basement available which could provide access for hardwiring and interconnection without the removal of interior finishes. 2. Work on the exterior which does not require entry into the interior for inspecStatus: finalType: ResidentialApplicant: Conor M ObrienEffective Date: 2014-08-25Permit Number: BLDG42443
August 20, 2014
Description: HVAC-LVL3 | Scope of work: HVAC WORK AND ENTIRE SYSTEM REPLACEMENT ** Identify number of each of the existing individual heating/cooling system being replaced, that serves an individual dwelling unit. Indicate the number of systems that apply: _X_Remove existing system and install new (boiler or forced air system) (INSTALL ONE 60,000 BTU FURNACE, 2 BATH FANS, GAS PIPING & DUCTWORK) __Install a new system to serve an existing non-conditioned space or addition REQUIRED FOR INSPECTION 1. HVAC equipment must be sized to ACCA manual J or an equivalent method. Heat loss calculations to be left next to appliances for inspection. Over-sizing of heating equipment must not exceed 43% and cooling equipment must not exceed 21%. 2. Documents relative to maintenance and startup testing (orsat) shall be affixed to the mechanical equipment. 3. All work done under this permit must be completed by a person with the proper Minneapolis installer competency card employed by the Minneapolis licensed permit Status: completeType: MechanicalBusiness Name: Mespo Heating & Cooling IncApplicant: Conor M ObrienEffective Date: 2014-08-20Permit Number: BLDG338293
August 13, 2014
Description: PLUMB 1 SINK, 1 GAS RANGE, GAS DRYER, 2 BASINS, 1 FLOOR DRAIN, 1 BATHTUB, 2 TOILETS, 1 WASHTRAY Properly plug the unused plumbing openings at the nearest live main or branch on the waste and vent system. Cement is not an acceptable method of disconnect. Approved plumbing materials must be used. Dead ends are not permitted except where necessary to extend piping for a cleanout so as to be accessible. The work must be done by a licensed plumbing contractor in which a permit and inspection is required before concealing. Carbon monoxide detectors are required in dwelling units in accordance with Minnesota Statute 299F.50. Please refer to the following website for additional information. http://www.dli.mn.gov/CCLD/PDF/bc_websmoke_co_06_07.pdf Plans approved by both the State of Minnesota Department of Health and the Department of Labor and Industry are required to be on site for all plumbing work conducted in hospitals, nursing homes, supervised living facilities, outpatient surgical centerStatus: finalType: PlumbingApplicant: Conor M ObrienEffective Date: 2014-08-13Permit Number: BLDG506751
August 4, 2014
Project Name: Robin O'BrienDescription: Code complianceStatus: finalType: Ele exst 1 or 2 familySub Type: Residential exstBusiness Name: King Electric INCApplicant: Robin O'brienFees: $110Effective Date: 2014-08-04Permit Number: ELE1401-00669
December 4, 2013
Description: HVAC work and entire system replacementStatus: DoneType: HVAC alterationsSub Type: BtmbBusiness Name: Mespo Heating & CoolingApplicant: Robin O'brienFees: $207Effective Date: 2013-12-04Permit Number: 4105706
November 4, 2013
Description: 1 sink 1 gas range gas dryer 2 basins 1 floor drain 1 bathtub 2 toilets 1 washtrayStatus: DoneType: plumbingSub Type: BtpaBusiness Name: Barr Web Industries, IncApplicant: Robin O'brienFees: $451Effective Date: 2013-11-04Permit Number: 5158507
September 9, 2013
Description: Kitchen and bathroom remodel and 9 new windows at single family dwelling (wss)Job Value: $18,500Status: DoneType: RemodelingSub Type: BireBusiness Name: Brian KallioinenApplicant: Robin O'brienFees: $596Effective Date: 2013-09-09Permit Number: 3086787
July 2, 2013
Description: Interior demolish in kitchen and 2nd floor bathroom. SckJob Value: $800Status: DoneType: RemodelingSub Type: BireBusiness Name: Brian KallioinenApplicant: Robin O'brienFees: $79Effective Date: 2013-07-02Permit Number: 3085403
June 24, 2013
Description: Tearoff and reroof house and porchStatus: DoneType: Building over the counterSub Type: BotcBusiness Name: Charlie's Angles LlcApplicant: Robin O'brienFees: $273Effective Date: 2013-06-24Permit Number: 1109732
January 1, 1900
Description: Replacing 700 of under ground electrical cable to existing transformerStatus: completeType: UtilityBusiness Name: XcelApplicant: Conor M ObrienEffective Date: 1900-01-01Permit Number: BLDG801600
January 1, 1900
Description: Reroof tearoff and reroof house and porch all exterior work to be completed within one year of permit issuance date per minneapolis city ordinance 89.165 all roof drains area drains or other stormwater or clearwater connections to the city's sanitary sewer system must be disconnected per chapter 56 of the minneapolis code of ordinances. Contact arvella greenway at 612 673 5899 if you questions. Carbon monoxide detectors are required in dwelling units in accordance with minnesota statute 299f.50. Please refer to the following website for additional information. Http://www.doli.state.mn.us/pdf/bcs_co_detectors_joint_memo_july06.pdfJob Value: $3,895Status: completeType: ResidentialBusiness Name: Charlie's Angles LLCApplicant: Conor M ObrienEffective Date: 1900-01-01Permit Number: BLDG133726
January 1, 1900
Description: Replace all siding soffit and fascia on house onlyJob Value: $8,000Status: completeType: ResidentialBusiness Name: SMA Exteriors & Restoration INCApplicant: Conor M ObrienFees: $232Effective Date: 1900-01-01Permit Number: BLDG816770
January 1, 1900
Description: Gas fix gas fixture replace/install - is this a new install(y/n)?____ - is this a replacement(y/n)?__y__ - fireplace(y/n)?___ - stove(y/n)?____ - dryer(y/n)?____ - water heater(y/n)?__y__ - gas grill(y/n)?____ - other: describe below carbon monoxide detectors are required in dwelling units in accordance with minnesota statute 299f.50. Please refer to the following website for additional information. Http://www.dli.mn.gov/ccld/pdf/bc_websmoke_co_06_07.pdfStatus: completeType: plumbingBusiness Name: Barr WEB Industries INCApplicant: Conor M ObrienEffective Date: 1900-01-01Permit Number: BLDG521112
January 1, 1900
Description: *irc1-r/r interior demolish in kitchen and 2nd floor bathroom. Sck separate permits are required for electrical plumbing and heating/air conditioning/ventilation work. Carbon monoxide alarms required in accordance with mn. Stat. 299f.50 irc 313.2.1. When interior alterations repairs or additions require a building permit or when one or more sleeping rooms are added or created in existing dwellings smoke detection shall be installed: a. On each level of the house b. In each bedroom c. In the hall or room outside of bedrooms. Exceptions: 1. Smoke alarms in existing areas shall not be required to be interconnected and hardwired where the alterations or repairs do not result in the removal of interior wall or ceiling finishes exposing the structure unless there is a crawl space or basement available which could provide access for hardwiring and interconnection without the removal of interior finishes. 2. Work on the exterior which does not require entry into the interior for inspection. CoJob Value: $800Status: completeType: ResidentialBusiness Name: Brian KallioinenApplicant: Conor M ObrienEffective Date: 1900-01-01Permit Number: BLDG69667

Current Ownership

Information about the current owner(s).

Property History

411 N 26th Ave has undefined property events records (listings, deeds, permits, tax, foreclosure, loan).

Property Events

Environment

Environmental factors around 411 N 26th Ave

School Information

Public/private schools serving 411 N 26th Ave

Neighborhood

This property is located in Hawthorne, Minneapolis, MN 55411.

Market Trends

Historical market data near 411 N 26th Ave over selected time period.

Nearby Properties on 26th Ave