  • Chat with Us
  • Submit Feedback
  • TopHap Academy
  • What's New?
Residential > House
Sold
08/05/2015
Sold Price
$--$--/ft²

3549 S 16th Ave
Minneapolis, MN 55407

3549 S 16th Ave, Minneapolis, MN 55407 is a 4 bed, 3 bath, 1,872 ft² house built in 1910 on a 0.110 acre lot with 21 construction permits. This house is currently off market, and it was last sold in 2015. The latest TopHap estimate of the house's value is $371,250.

Property Valuations

Latest estimates for 3549 S 16th Ave based on TopHap automated valuation model (AVM).

Permits

3549 S 16th Ave has 21 permit records of total value of $52,800.

Permit History
21
Permits
$52,800
Total Permit Value
March 7, 2023
Description: 4.64 kw air conditioning roof-mounted solar power systemStatus: issuedType: Electrical permitSub Type: One-family dwellingApplicant: Liz and Peter ThompsonFees: $61Effective Date: 2023-03-07Permit Number: ELE2303-01714
February 28, 2017
Description: *irc1-r/r construct/replace stoop and steps on front of existing single family dwelling. (sza) minimum landing size 36 by 36 hand rail must be 34 to 38 above nosing of treads (required if 4 or more risers) 7 3/4 maximum rise allowed and 10 minimum tread depth required. The greatest riser height whithin any flight of stairs shall not exceed the smallest by more than 3/8 inch. The greatest tread depth whithin any flight of stairs shall not exceed the smallest by more than 3/8 inch. Landings located more than 30 above grade shall have guards not less than 36 in height. Open sides of stairs with a total rise of more than 30 above the floor or grade below shall have guards not less than 34 in height measured vertically from the nosing of the treads. Required guards shall have intermediate rails or ornamental closures which do not allow passage of a sphere 4 or more in diameter. The triangular openings formed by the riser tread and bottom rail of a guard at the open side of a stairway are pStatus: finalType: ResidentialApplicant: Elizabeth MalherekEffective Date: 2017-02-28Permit Number: BLDG49350
June 24, 2015
Status: OpenType: Street use permitSub Type: BsuBusiness Name: Dicks Sanitation ServiceApplicant: Elizabeth M MalherekFees: $81Effective Date: 2015-06-24Permit Number: 1045352
June 5, 2015
Job Value: $2,000Status: OpenType: RemodelingSub Type: BireBusiness Name: Peter ThompsonApplicant: Elizabeth M MalherekFees: $138Effective Date: 2015-06-05Permit Number: 3098302
March 17, 2010
Description: plumbingfix specify the type of fixtures by entering the quantity in the list below: water closets____ urinals_____ bathroom tubs____ basins____ sinks_____ wash trays_____ showers_____ floor drains____ extensions_____ misc fixtures___1_ electric water heaters_____ other gas dryer properly plug the unused plumbingopenings at the nearest live main or branch on the waste and vent system. Cement is not an acceptable method of disconnect. Approved plumbingmaterials must be used. Dead ends are not permitted except where necessary to extend piping for a cleanout so as to be accessible. The work must be done by a licensed plumbingcontractor in which a permit and inspection is required before concealing. Carbon monoxide detectors are required in dwelling units in accordance with minnesota statute 299f.50. Please refer to the following website for additional information. Http://www.doli.state.mn.us/pdf/bcs_co_detectors_joint_memo_july06.pdf plans approved by both the state of minnesota deparStatus: finalType: PlumbingApplicant: Elizabeth MalherekEffective Date: 2010-03-17Permit Number: BLDG466757
March 16, 2010
Description: Specify the type of fixtures by entering the quantity in the list below:Status: DoneType: plumbingSub Type: BtpaBusiness Name: Arnold Bing PlumbingApplicant: Elizabeth M MalherekFees: $70Effective Date: 2010-03-16Permit Number: 5114171
March 10, 2010
Description: *irc1-r/r convert duplex to single family dwelling. Frame closed main level 2 extension door locations. Demolish back (dmh#2) stairway and install 2 x 8 joists above. Remodel kitchen and bathroom with fixtures in same locations. Glass block at bathroomrm window opening. Remodel 2nd floor bathroom and install new parition wall. Make new opening with (2) 12 header to enlarge master bedroom and finish for master closet. Install insulation and vapor barrier at exterior wall conditions. Replace storm windows. Sac: 1 credit cement fiber-cement or glass mat gypsum backers shall be used as backers for wall tile in bathroomtub/shower locations and installed per manufacturer recommendations per 2006 irc 702.4.2 separate permits are required for electrical plumbingand heating/air conditioning/ventilation work. This work must be completed by a licensed contractor in a multi-family dwelling. Carbon monoxide alarms required in accordance with mn. Stat. 299f.50 irc 313.2.1. When interior alterations Status: finalType: ResidentialApplicant: Elizabeth MalherekEffective Date: 2010-03-10Permit Number: BLDG31719
March 5, 2010
Description: MECH MECH | WARM AIR HEATING SYSTEMS | Scope of work: IN VACANT HOUSE: RE-VENT DRYER Carbon monoxide detectors are required in dwelling units in accordance with Minnesota Statute 299F.50. Please refer to the following website for additional information. http://www.doli.state.mn.us/pdf/bcs_co_detectors_joint_memo_july06.pdf HVAC equipment is allowed as a permitted obstruction in a required side or rear yard as follows: Air-conditioning systems, heating, ventilating, and filtering equipment, not to exceed four (4) feet in height and adjacent to a nonresidential use or adjacent to a residential use which is equipped with central air conditioning or which has no windows or doors in the wall immediately abutting the yard. Such equipment may project into a corner side yard, provided such equipment is located no closer than three (3) feet from the corner side lot line. In no case shall any permitted obstruction be located closer than one (1) foot from the property line. If you have any questiStatus: completeType: MechanicalBusiness Name: Edina Heating & Cooling IncApplicant: Elizabeth MalherekEffective Date: 2010-03-05Permit Number: BLDG331438
March 2, 2010
Description: Install dishwasher and replace range with 40000 btu rangeStatus: DoneType: plumbingSub Type: BtpaBusiness Name: H & H PlumbingApplicant: Elizabeth M MalherekFees: $96Effective Date: 2010-03-02Permit Number: 5113778
March 2, 2010
Description: plumbingfix specify the type of fixtures by entering the quantity in the list below: water closets__2__ urinals_____ bathroom tubs__2__ basins__2__ sinks___1__ wash trays___1__ showers_____ floor drains____ extensions_____ misc fixtures____ electric water heaters_____ other: specify below properly plug the unused plumbingopenings at the nearest live main or branch on the waste and vent system. Cement is not an acceptable method of disconnect. Approved plumbingmaterials must be used. Dead ends are not permitted except where necessary to extend piping for a cleanout so as to be accessible. The work must be done by a licensed plumbingcontractor in which a permit and inspection is required before concealing. Carbon monoxide detectors are required in dwelling units in accordance with minnesota statute 299f.50. Please refer to the following website for additional information. Http://www.doli.state.mn.us/pdf/bcs_co_detectors_joint_memo_july06.pdf plans approved by both the state of minnesStatus: finalType: PlumbingApplicant: Elizabeth MalherekEffective Date: 2010-03-02Permit Number: BLDG462580
February 22, 2010
Description: In vacant house: re-vent dryerStatus: DoneType: MechanicalSub Type: BtmaBusiness Name: Edina Heating & Cooling, IncApplicant: Elizabeth M MalherekFees: $70Effective Date: 2010-02-22Permit Number: 4088904
November 6, 2009
Description: Specify the type of fixtures by entering the quantity in the list below:Status: DoneType: plumbingSub Type: BtpaBusiness Name: Perfect Plumbing, IncApplicant: Elizabeth M MalherekFees: $274Effective Date: 2009-11-06Permit Number: 5110879
September 24, 2009
Description: Convert duplex to single family dwelling. Frame closed main level 2 extension door locations. Demolish back (dmh#2)Job Value: $40,000Status: DoneType: RemodelingSub Type: BireBusiness Name: Provident Real Estate Advisors LlcApplicant: Elizabeth M MalherekFees: $1,117Effective Date: 2009-09-24Permit Number: 3061311
September 27, 2007
Description: R3/rem const. Bathroom in basement ( existing condition ) ( housing insp. Required home owner to apply for building. Permit for this existing condition ) contract provided for code compliance and fire repairs____na____ separate permits are required for electrical plumbingand heating/air conditioning/ventilation work. R317.1.1 alterations repairs or additions. When interior alterations repairs or additions requiring a permit occur or when one or more sleeping rooms are added or created in existing dwellings the individual dwelling unit shall be provided with smoke alarms located as required for new dwellings; the smoke alarms shall be interconnected and hardwired. Exceptions: 1. Smoke alarms in existing areas shall not be required to be interconnected and hardwired where the alterations or repairs do not result in the removal of interior wall or ceiling finishes exposing the structure unless there is a crawl space or basement available which could provide access for hardwiring and interStatus: finalType: CommercialApplicant: Elizabeth MalherekEffective Date: 2007-09-27Permit Number: BLDG236873
September 7, 2007
Description: Const. Bathroom in basement ( existing condition )Job Value: $1,000Status: DoneType: RemodelingSub Type: BireBusiness Name: Laura P LunaApplicant: Elizabeth M MalherekFees: $64Effective Date: 2007-09-07Permit Number: 3049480
November 24, 2003
Description: Mechanical mechanical | warm air heating systems | scope of work: install 120 mbh boiler mechanical | scope of work: install 120 mbh boiler mechanical | scope of work: install 120 mbh boiler mechanical | scope of work: install 120 mbh boilerStatus: finalType: MechanicalApplicant: Elizabeth MalherekEffective Date: 2003-11-24Permit Number: BLDG388043
August 31, 1999
Description: Replace 1 ckt -- boilerJob Value: $100Status: DoneType: ElectricalSub Type: BteaBusiness Name: Harrison ElectricApplicant: Elizabeth M MalherekFees: $40Effective Date: 1999-08-31Permit Number: 1009291
August 31, 1999
Description: Install 120 mbh boilerJob Value: $3,200Status: DoneType: MechanicalSub Type: BtmaBusiness Name: Team Mechanical, IncApplicant: Elizabeth M MalherekFees: $89Effective Date: 1999-08-31Permit Number: 4005374
September 4, 1997
Description: Const.22x16x8 det. Fr. Garage residenceJob Value: $6,500Status: DoneType: BuildingSub Type: BApplicant: Elizabeth M Malherek0Effective Date: 1997-09-04Permit Number: 646225
January 1, 1900
Description: plumbing install dishwasher and replace range with 40000 btu range properly plug the unused plumbing openings at the nearest live main or branch on the waste and vent system. Cement is not an acceptable method of disconnect. Approved plumbing materials must be used. Dead ends are not permitted except where necessary to extend piping for a cleanout so as to be accessible. The work must be done by a licensed plumbing contractor in which a permit and inspection is required before concealing. Carbon monoxide detectors are required in dwelling units in accordance with minnesota statute 299f.50. Please refer to the following website for additional information. Http://www.doli.state.mn.us/pdf/bcs_co_detectors_joint_memo_july06.pdf plans approved by both the state of minnesota department of health and the department of labor and industry are required to be on site for all plumbing work conducted in hospitals nursing homes supervised living facilities outpatient surgical centers boarding care hStatus: completeType: plumbingBusiness Name: H&H PlumbingApplicant: Elizabeth MalherekEffective Date: 1900-01-01Permit Number: BLDG501276
January 1, 1900
Description: Sewer repair in yardStatus: completeType: SewerBusiness Name: Genes Water & SewerApplicant: Elizabeth MalherekFees: $160Effective Date: 1900-01-01Permit Number: BLDG735636

Current Ownership

Information about the current owner(s).

Property History

3549 S 16th Ave has undefined property events records (listings, deeds, permits, tax, foreclosure, loan).

Property Events

Environment

Environmental factors around 3549 S 16th Ave

School Information

Public/private schools serving 3549 S 16th Ave

Neighborhood

This property is located in Powderhorn Park, Minneapolis, MN 55407.

Market Trends

Historical market data near 3549 S 16th Ave over selected time period.