  • Chat with Us
  • Submit Feedback
  • TopHap Academy
  • What's New?
Residential > Multi-family
Sold
01/07/2020
Sold Price
$279,900$175/ft²

3516 S 20th Ave
Minneapolis, MN 55407

3516 S 20th Ave, Minneapolis, MN 55407 is a 2 bed, 2 bath, 1,604 ft² multi-family home house built in 1900 on a 0.140 acre lot with 29 construction permits. This multi-family home is currently off market, and it was last sold in 2020 for $279,900. The latest TopHap estimate of the multi-family home's value is $330,900.

Property Valuations

Latest estimates for 3516 S 20th Ave based on TopHap automated valuation model (AVM).

Permits

3516 S 20th Ave has 29 permit records of total value of $14,547.

Permit History
29
Permits
$14,547
Total Permit Value
June 2, 2022
Description: Bathfan unit #2Status: finalType: Electrical permitSub Type: Two-family dwellingApplicant: Complete Electrical ServicesFees: $36Effective Date: 2022-06-02Permit Number: ELE2205-09087
November 12, 2021
Description: Knob and tube abatementStatus: issuedType: Electrical permitSub Type: One-family dwellingApplicant: Margaret BrockFees: $36Effective Date: 2021-11-12Permit Number: ELE2111-05706
July 31, 2015
Description: HVAC-LVL3 | Scope of work: HVAC WORK AND ENTIRE SYSTEM REPLACEMENT ** NO NEW CONSTRUCTION - Tear-downs and major remodels are considered new construction ** Identify number of each of the existing individual heating/cooling system being replaced, that serves an individual dwelling unit. Indicate the number of systems that apply: _X_Remove existing system and install new (boiler or forced air system) (REPLACE FURNACE GRAVITY CHANGE OUT CARRIER 595CSA060 95% 60,000 BTUS AND ALL NEW DUCTWORK) __Install a new system to serve an existing non-conditioned space REQUIRED FOR INSPECTION 1. HVAC equipment must be sized to ACCA manual J or an equivalent method. Heat loss calculations to be left next to appliances for inspection. Over-sizing of heating equipment must not exceed 43% and cooling equipment must not exceed 21%. 2. Documents relative to maintenance and startup testing (orsat) shall be affixed to the mechanical equipment. 3. All work done under this permit must be completed by a person Status: completeType: MechanicalBusiness Name: Residential Htg & A / C IncApplicant: Christie NixonEffective Date: 2015-07-31Permit Number: BLDG378390
July 30, 2015
Project Name: Res HeatDescription: Furnace change outStatus: finalType: Ele new 1 or 2 familyBusiness Name: ST Joseph Electric INCApplicant: Christine NixonFees: $36Effective Date: 2015-07-30Permit Number: ELE1507-09276
July 17, 2015
Status: DoneType: HVAC alterationsSub Type: BtmbBusiness Name: Residential Htg & A/c, IncApplicant: Amy Powers & Christie NixonFees: $209Effective Date: 2015-07-17Permit Number: 4113763
July 14, 2015
Project Name: NixonDescription: Install new service panel and rewire most of the outlets throughout homeStatus: finalType: Ele exst 1 or 2 familyBusiness Name: Brothers Electric COApplicant: Christie NixonFees: $139Effective Date: 2015-07-14Permit Number: ELE1507-03549
December 17, 2014
Status: OpenType: Plumbing PermitSub Type: PlumbingBusiness Name: NORBLOM PLUMBINGApplicant: 3516 20TH LLCFees: $86Effective Date: 2014-12-17Permit Number: BLDG518344
December 17, 2014
Description: Replace water heaterStatus: OpenType: plumbingSub Type: BtpaBusiness Name: Norblom PlumbingApplicant: Amy Powers & Christie NixonFees: $86Effective Date: 2014-12-17Permit Number: 5172977
October 17, 2012
Description: *irc2-r/r main floor bathroom remodel of existing two family dwelling. Aaj#2 also replace existing bathroom window with new glass block window using same openings. Sound/fire test assembly: ***repair existing bathroom floor/ceiling assembly per ga file no. Fc 5110. See attached*** see plan for detailed scope of work to be done as well as plan review comments. Separate permits are required for electrical plumbingand heating/air conditioning/ventilation work. This work must be completed by a licensed contractor in a multi-family dwelling. Carbon monoxide alarms required in accordance with mn. Stat. 299f.50 irc 313.2.1. When interior alterations repairs or additions require a building permit or when one or more sleeping rooms are added or created in existing dwellings smoke detection shall be installed: a. On each level of the house b. In each bedroom c. In the hall or room outside of bedrooms. Exceptions: 1. Smoke alarms in existing areas shall not be required to be interconnected and haStatus: finalType: ResidentialApplicant: Christie NixonEffective Date: 2012-10-17Permit Number: BLDG39909
October 17, 2012
Description: plumbingfix specify the type of fixtures by entering the quantity in the list below: water closets_1___ urinals_____ bathroom tubs__1__ basins_1___ sinks_____ wash trays_____ showers_____ floor drains____ extensions_____ misc fixtures____ electric water heaters_____ other: specify below properly plug the unused plumbingopenings at the nearest live main or branch on the waste and vent system. Cement is not an acceptable method of disconnect. Approved plumbingmaterials must be used. Dead ends are not permitted except where necessary to extend piping for a cleanout so as to be accessible. The work must be done by a licensed plumbingcontractor in which a permit and inspection is required before concealing. Carbon monoxide detectors are required in dwelling units in accordance with minnesota statute 299f.50. Please refer to the following website for additional information. Http://www.dli.mn.gov/ccld/pdf/bc_websmoke_co_06_07.pdf plans approved by both the state of minnesota department ofStatus: finalType: PlumbingApplicant: Christie NixonEffective Date: 2012-10-17Permit Number: BLDG517457
September 25, 2012
Project Name: Rewire 1st Floor BathroomStatus: finalType: Ele exst 1 or 2 familySub Type: Residential exstBusiness Name: John Koppi Electric LLCApplicant: Amy PowersFees: $75Effective Date: 2012-09-25Permit Number: ELE1209-00931
August 22, 2012
Description: Specify the type of fixtures by entering the quantity in the list below:Status: DoneType: plumbingSub Type: BtpaBusiness Name: Servey Plumbing, IncApplicant: Amy Powers & Christie NixonFees: $118Effective Date: 2012-08-22Permit Number: 5142533
August 8, 2012
Description: Main floor bathroom remodel of existing two family dwelling. Aaj#2Job Value: $4,500Status: DoneType: RemodelingSub Type: BireBusiness Name: Personal Pride Construction LtdApplicant: Amy Powers & Christie NixonFees: $227Effective Date: 2012-08-08Permit Number: 3079928
February 26, 2007
Description: Steps reconstruct concrete landing and steps at front of single family dwelling over existing foundation. (dmh#2) 3 risers. General comments: minimum landing size 36 by 36 grippable hand rail height must be 34 to 38 above nosing of treads (required if 4 or more risers) 8 maximum rise allowed and 9 minimum tread allowed 36 mimimum guard rail height required if 30 or greater in height frost footing depth must be 42 minimum depth contact gopher state one call prior to digging footings and foundations (651) 454-0002. Required inspections: footing and foundation before placing concrete (if project involves pouring concrete); structural framing after all mechanical rough-ins are approved; insulation and vapor barrier prior to concealment; final inspection after all work completedStatus: finalType: ResidentialApplicant: Christie NixonEffective Date: 2007-02-26Permit Number: BLDG65745
May 4, 2006
Description: Reconstruct concrete landing and steps at front of single family dwelling over existing foundation. (dmh#2)Job Value: $1,800Status: DoneType: RemodelingSub Type: BireBusiness Name: Quality Home Improvements MplsApplicant: Amy Powers & Christie NixonFees: $91Effective Date: 2006-05-04Permit Number: 3041164
September 20, 2004
Description: plumbing replace gas piping to range install anti-tip deviceStatus: completeType: plumbingBusiness Name: H.O. Soderlin IncApplicant: Christie Nixon0Effective Date: 2004-09-20Permit Number: BLDG409704
June 2, 2004
Description: Windows replace storm windows no change in opening size r310.1.5 replacement windows. Replacement windows installed in buildings meeting the scope of the international residential code shall be exempt from the requirements of sections r310.1.1 r310.1.2 and r310.1.3 if the replacement window meets the following conditions: 1. The existing height and width net clear opening shall not be reduced by more than 2 inches (51 mm) in either dimension; 2. The rooms or areas are not used for any minnesota state licensed purpose; 3. The window is not required pursuant to the minnesota fire code; 4. The sleeping room is not undergoing an addition remodeling or a change in occupancy; and 5. The window meets the provisions of the minneapolis housing maintenance code (see below) chapter 244.410: every sleeping room located below the fourth floor shall have at least one window or exterior door approved for emergency exit or rescue. Where windows are provided they shall have a sill height not more than Status: finalType: ResidentialApplicant: Christie NixonEffective Date: 2004-06-02Permit Number: BLDG84160
August 28, 2003
Description: Replace gas piping to range install anti-tip deviceJob Value: $500Status: DoneType: plumbingSub Type: BtpaBusiness Name: H.o. Soderlin, IncApplicant: Amy Powers & Christie NixonFees: $52Effective Date: 2003-08-28Permit Number: 5045549
August 25, 2003
Description: Replace storm windows no change in opening sizeJob Value: $1,657Status: DoneType: Building over the counterSub Type: BotcBusiness Name: Benada Aluminum Of MinnesotaApplicant: Amy Powers & Christie NixonFees: $64Effective Date: 2003-08-25Permit Number: 1051576
October 2, 2000
Description: Addition ground loop for water meterStatus: DoneType: ElectricalSub Type: BteaBusiness Name: D & L ElectricApplicant: Amy Powers & Christie NixonFees: $41Effective Date: 2000-10-02Permit Number: 1024183
March 10, 2000
Description: Exterior tearoff and reroof -- house and garage; ice and water all exterior work to be completed within one year of permit issuance date per minneapolis city ordinance section 89.165Status: finalType: ResidentialApplicant: Christie NixonEffective Date: 2000-03-10Permit Number: BLDG189010
November 13, 1999
Description: Tearoff and reroof -- house and garage; ice and waterJob Value: $4,590Status: DoneType: Building over the counterSub Type: BotcBusiness Name: Citywide Home ImprovementApplicant: Amy Powers & Christie NixonFees: $102Effective Date: 1999-11-13Permit Number: 1018267
January 1, 1900
Description: Install bathroom fanStatus: completeType: MechanicalBusiness Name: Perfection Heating & AIR Conditioning INCApplicant: Sam H BrockFees: $85Effective Date: 1900-01-01Permit Number: BLDG946090
January 1, 1900
Description: Install replacement furnaceStatus: completeType: MechanicalBusiness Name: Perfection Heating & AIR Conditioning INCApplicant: Sam H BrockFees: $133Effective Date: 1900-01-01Permit Number: BLDG927191
January 1, 1900
Description: Meter move q3 - 2022 batch #4Status: issuedType: plumbingBusiness Name: Center Point Energy Resource CorpApplicant: Sam H BrockFees: $85Effective Date: 1900-01-01Permit Number: BLDG981995
January 1, 1900
Description: Meter move q3 - 2022 batch #4Status: issuedType: plumbingBusiness Name: Center Point Energy Resource CorpApplicant: Sam H BrockFees: $85Effective Date: 1900-01-01Permit Number: BLDG981994
January 1, 1900
Description: Gas rangeStatus: completeType: plumbingBusiness Name: Warners Stellian CO INCApplicant: Sam H BrockFees: $85Effective Date: 1900-01-01Permit Number: BLDG785939
January 1, 1900
Description: Replace water heaterStatus: completeType: plumbingBusiness Name: Urban Pine Plumbing & Mechanical INCApplicant: Sam H BrockFees: $85Effective Date: 1900-01-01Permit Number: BLDG790333
January 1, 1900
Description: New front storm door one new basement glass block windowJob Value: $1,500Status: completeType: ResidentialBusiness Name: Homecare INCApplicant: Sam H BrockFees: $85Effective Date: 1900-01-01Permit Number: BLDG786623

Current Ownership

Information about the current owner(s).

Property History

3516 S 20th Ave has undefined property events records (listings, deeds, permits, tax, foreclosure, loan).

Property Events

Environment

Environmental factors around 3516 S 20th Ave

School Information

Public/private schools serving 3516 S 20th Ave

Neighborhood

This property is located in Corcoran, Minneapolis, MN 55407.

Market Trends

Historical market data near 3516 S 20th Ave over selected time period.

Nearby Properties on 20th Ave