  • Chat with Us
  • Submit Feedback
  • TopHap Academy
  • What's New?
Residential > House
Sold
12/04/2020
Sold Price
$185,000$149/ft²

3435 N Bryant Ave
Minneapolis, MN 55412

3435 N Bryant Ave, Minneapolis, MN 55412 is a 2 bed, 1 bath, 1,240 ft² house built in 1890 on a 0.130 acre lot with 19 construction permits. This house is currently off market, and it was last sold in 2020 for $185,000. The latest TopHap estimate of the house's value is $201,283.

Property Valuations

Latest estimates for 3435 N Bryant Ave based on TopHap automated valuation model (AVM).

Permits

3435 N Bryant Ave has 19 permit records of total value of $17,117.

Permit History
19
Permits
$17,117
Total Permit Value
September 24, 2009
Description: REROOF TEAROFF AND REROOF HOUSE, INCLUDING FRONT AND PORCHES WITH NEW ROOF VENTS AND STACK BOOTS. All exterior work to be completed within one year of permit issuance date per Minneapolis City Ordinance 89.165 All roof drains, area drains, or other stormwater or clearwater connections to the City's sanitary sewer system must be disconnected per Chapter 56 of the Minneapolis Code of Ordinances. Contact Arvella Greenway at 612 673 5899 if you questions. Carbon monoxide detectors are required in dwelling units in accordance with Minnesota Statute 299F.50. Please refer to the following website for additional information. http://www.doli.state.mn.us/pdf/bcs_co_detectors_joint_memo_july06.pdfStatus: finalType: ResidentialApplicant: Tkpk Group LlcEffective Date: 2009-09-24Permit Number: BLDG114223
September 1, 2009
Description: Tearoff and reroof house including front and porches with new roof vents and stack bootsStatus: DoneType: Building over the counterSub Type: BotcBusiness Name: Curtis Schmitz Construction IncApplicant: Tkpk Group LlcFees: $141Effective Date: 2009-09-01Permit Number: 1081518
June 5, 2009
Description: *IRC1-R/R REMODEL EXISTING KITCHEN FLOOR OF A SINGLE FAMILY HOUSE. AAJ#2. - REPLACE FOUR (4) EXISTING ROTTEN FLOOR JOISTS @ 7'0" SPAN WITH NEW 2 X 10 JOISTS @ 16" O.C. - SISTER NEW 2 X 8 FLOOR JOISTS @ 16" O.C. TO EXISTING 2 X 8 JOISTS @ 12'0" SPAN. - INSTALL 3/4" OSB FLOOR SHEATHING AND TREATED RIM JOIST WITH PLATE. - UPDATE CARBON MONOXIDE ALARM AND SMOKE DETECTORS PER CODE REQUIREMENT. SEPARATE PERMITS ARE REQUIRED FOR ELECTRICAL, PLUMBING, AND HEATING/AIR CONDITIONING/VENTILATION WORK. THIS WORK MUST BE COMPLETED BY A LICENSED CONTRACTOR IN A MULTI-FAMILY DWELLING. CARBON MONOXIDE ALARMS REQUIRED IN ACCORDANCE WITH MN. STAT. 299F.50 IRC 313.2.1. When interior alterations, repairs or additions require a building permit or when one or more sleeping rooms are added or created in existing dwellings, smoke detection shall be installed: A. on each level of the house B. in each bedroom C. in the hall or room outside of bedrooms. Exceptions: 1. Smoke alarms in existing areas shall not be rStatus: finalType: ResidentialApplicant: Tkpk Group LlcEffective Date: 2009-06-05Permit Number: BLDG76738
June 2, 2009
Description: MECH MECH | WARM AIR HEATING SYSTEMS | Scope of work: INSTALL BRYANT BRAND, 2 TON AIR CONDITIONING UNIT. INSTALL RETURN AND SUPPLY DUCTS TO KITCHEN AND 2ND FLOOR. Carbon monoxide detectors are required in dwelling units in accordance with Minnesota Statute 299F.50. Please refer to the following website for additional information. http://www.doli.state.mn.us/pdf/bcs_co_detectors_joint_memo_july06.pdf HVAC equipment is allowed as a permitted obstruction in a required side or rear yard as follows: Air-conditioning systems, heating, ventilating, and filtering equipment, not to exceed four (4) feet in height and adjacent to a nonresidential use or adjacent to a residential use which is equipped with central air conditioning or which has no windows or doors in the wall immediately abutting the yard. Such equipment may project into a corner side yard, provided such equipment is located no closer than three (3) feet from the corner side lot line. In no case shall any permitted obstruction be lStatus: finalType: MechanicalBusiness Name: Paul Stafford Electric Htg & CoolingApplicant: Tkpk Group LlcEffective Date: 2009-06-02Permit Number: BLDG303753
May 29, 2009
Description: PLUM FIX Specify the type of fixtures by entering the quantity in the list below: Water Closets____ Urinals_____ Bath Tubs____ Basins____ Sinks___1__ Wash Trays_____ Showers_____ Floor Drains____ Extensions_____ Misc Fixtures___2 GARBAGE DISPOSAL AND DISHWASHER_ Electric Water Heaters_____ Other: Specify below Owner's Name _________________ Phone# ______________ Properly plug the unused plumbing openings at the nearest live main or branch on the waste and vent system. Cement is not an acceptable method of disconnect. Approved plumbing materials must be used. Dead ends are not permitted except where necessary to extend piping for a cleanout so as to be accessible. The work must be done by a licensed plumbing contractor in which a permit and inspection is required before concealing. Carbon monoxide detectors are required in dwelling units in accordance with Minnesota Statute 299F.50. Please refer to the following website for additional information. http://www.doli.state.mn.us/pdf/bcs_co_Status: finalType: PlumbingBusiness Name: Hovde Plbg & Htg IncApplicant: Tkpk Group LlcEffective Date: 2009-05-29Permit Number: BLDG457667
April 20, 2009
Description: Install bryant brand 2 ton air conditioning unit. Install return and supply ducts to kitchen and 2nd floorStatus: DoneType: MechanicalSub Type: BtmaBusiness Name: Paul Stafford Electric, Htg & CoolingApplicant: Tkpk Group LlcFees: $96Effective Date: 2009-04-20Permit Number: 4081970
April 8, 2009
Description: Specify the type of fixtures by entering the quantity in the list below:Status: DoneType: plumbingSub Type: BtpaBusiness Name: Hovde Plbg & Htg IncApplicant: Tkpk Group LlcFees: $206Effective Date: 2009-04-08Permit Number: 5104769
April 6, 2009
Description: MECH MECH | WARM AIR HEATING SYSTEMS | Scope of work: REPLACE FURNACE & 80,000 BTU GAS BR. MORRIS LANDIN 612 207-1929 MECH | Scope of work: REPLACE FURNACE & 80,000 BTU GAS BR. MORRIS LANDIN 612 207-1929 MECH | Scope of work: REPLACE FURNACE & 80,000 BTU GAS BR. MORRIS LANDIN 612 207-1929 MECH | Scope of work: REPLACE FURNACE & 80,000 BTU GAS BR. MORRIS LANDIN 612 207-1929Status: finalType: MechanicalBusiness Name: Dave's Heating Air Conditioning & ApplianceApplicant: Tkpk Group LlcEffective Date: 2009-04-06Permit Number: BLDG286865
March 30, 2009
Description: Remodel existing kitchen floor of a single family house. Aaj#2Job Value: $1,200Status: DoneType: RemodelingSub Type: BireBusiness Name: Mike Tischler Construction IncApplicant: Tkpk Group LlcFees: $129Effective Date: 2009-03-30Permit Number: 3057963
March 16, 2009
Description: Install drain tile systemStatus: DoneType: Building over the counterSub Type: BotcBusiness Name: Advanced Waterproofing Fdn RepairApplicant: Tkpk Group LlcFees: $118Effective Date: 2009-03-16Permit Number: 1078227
February 23, 2009
Description: Replace an existing window with like/kind-no change to existing rough opening sizeStatus: DoneType: Building over the counterSub Type: BotcBusiness Name: The Home Depot - Home ServicesApplicant: Tkpk Group LlcFees: $169Effective Date: 2009-02-23Permit Number: 1078032
October 13, 2006
Description: PLUM FIX Specify the type of fixtures by entering the quantity in the list below: Water Closets__1__ Urinals_____ Bath Tubs__1__ Basins__1__ Sinks__1___ Wash Trays__1___ Showers_____ Floor Drains____ Extensions_____ Misc Fixtures____ Electric Water Heaters__1___ Other: Specify below Owner's Name _________________ Phone# ______________Status: finalType: PlumbingApplicant: Tkpk Group LlcEffective Date: 2006-10-13Permit Number: BLDG445310
June 22, 2006
Description: Specify the type of fixtures by entering the quantity in the list below:Status: DoneType: plumbingSub Type: BtpaBusiness Name: A-aarons PlumbingApplicant: Tkpk Group LlcFees: $184Effective Date: 2006-06-22Permit Number: 5077576
June 12, 2006
Description: Replace furnace & 80, 000 btu gas BRJob Value: $4,000Status: DoneType: MechanicalSub Type: BtmaBusiness Name: Dave's Heating, Air Conditioning & ApplianceApplicant: Tkpk Group LlcFees: $117Effective Date: 2006-06-12Permit Number: 4061823
March 6, 2003
Description: MECH MECH | WARM AIR HEATING SYSTEMS | Scope of work: REPLACE FURNACE @ 88MBH - THEO ADEBAYO @ 612-710-0906 MECH | Scope of work: REPLACE FURNACE @ 88MBH - THEO ADEBAYO @ 612-710-0906 MECH | Scope of work: REPLACE FURNACE @ 88MBH - THEO ADEBAYO @ 612-710-0906 MECH | Scope of work: REPLACE FURNACE @ 88MBH - THEO ADEBAYO @ 612-710-0906Status: finalType: MechanicalApplicant: Tkpk Group LlcEffective Date: 2003-03-06Permit Number: BLDG262170
December 26, 2002
Description: 1 circuit; wire furnaceStatus: DoneType: ElectricalSub Type: BteaBusiness Name: Blaine Htg, Ac & Electric, IncApplicant: Tkpk Group LlcFees: $36Effective Date: 2002-12-26Permit Number: 1052207
December 23, 2002
Description: Replace furnace @ 88mbh - theo adebayo @ 612-710-0906Job Value: $1,800Status: DoneType: MechanicalSub Type: BtmaBusiness Name: Centerpoint Energy/minnegascoApplicant: Tkpk Group LlcFees: $62Effective Date: 2002-12-23Permit Number: 4033739
January 1, 1900
Description: Drain tile install drain tile system. 1. Which walls? north south east west 2. Interior or exterior? ___ext _____ 3. Will more than 500 sq ft of earth be disturbed? if yes then a soil erosion control permit is required. Permit applicant is responsible for protecting adjacent property. Shoring or other means may need to be installed. Where the basement slab is repaired reinforce with 2 - #3 continuous (lap 2'-0") in center of thickness of slab. When the valuation of an addtion alteration or repair to a dwelling exceeds $1, 000 and a permit is required or when one or more sleeping rooms are added or created smoke detection shall be installed: a. On each level of the house b. In each bedroom c. In the hall or room outside of bedrooms detectors may be battery operated except that where new construction takes place or where the wiring will be exposed detectors shall be hard-wired with a battery back-up. See minneapolis inspections informational bulletin for details. Carbon monoxide detectorJob Value: $3,680Status: completeType: ResidentialBusiness Name: Advanced Waterproofing FDN RepairApplicant: Tshibangu G MutandaEffective Date: 1900-01-01Permit Number: BLDG104702
January 1, 1900
Job Value: $6,437Status: completeType: ResidentialBusiness Name: THE Home Depot AT Home ServicesApplicant: Tshibangu G MutandaEffective Date: 1900-01-01Permit Number: BLDG108535

Current Ownership

Information about the current owner(s).

Property History

3435 N Bryant Ave has undefined property events records (listings, deeds, permits, tax, foreclosure, loan).

Property Events

Environment

Environmental factors around 3435 N Bryant Ave

School Information

Public/private schools serving 3435 N Bryant Ave

Neighborhood

This property is located in Mckinley, Minneapolis, MN 55412.

Market Trends

Historical market data near 3435 N Bryant Ave over selected time period.

Nearby Properties on Bryant Ave