?
  • Chat with Us
  • Submit Feedback
  • TopHap Academy
  • What's New?
Residential > House
Sold
02/04/2000
Sold Price
$73,000$52/ft²

3215 S 19th Ave
Minneapolis, MN 55407

3215 S 19th Ave, Minneapolis, MN 55407 is a 3 bed, 2 bath, 1,395 ft² house built in 1926 on a 0.140 acre lot with 17 construction permits. This house is currently off market, and it was last sold in 2000 for $73,000. The latest TopHap estimate of the house's value is $274,087.

Property Valuations

Latest estimates for 3215 S 19th Ave based on TopHap automated valuation model (AVM).

Permits

3215 S 19th Ave has 17 permit records of total value of $25,629.

Permit History
17
Permits
$25,629
Total Permit Value
June 8, 2016
Description: WATER HTR Replace existing water heater - Is this a gas water heater(y/n)? @ 40,000 BTU - Is this an electric water heater(y/n)?__ NOTE: an electric water heater replacement also requires an Electrical permit - Other: describe below Carbon monoxide detectors are required in dwelling units in accordance with Minnesota Statute 299F.50. Please refer to the following website for additional information. http://www.dli.mn.gov/CCLD/PDF/bc_websmoke_co_06_07.pdfStatus: completeType: PlumbingBusiness Name: Centraire Heating & Air Conditioning IncApplicant: Antonio Andrade CalzadaEffective Date: 2016-06-08Permit Number: BLDG491807
April 16, 2012
Description: Replace existing water heaterStatus: OpenType: plumbingSub Type: BtpaBusiness Name: Centraire Htg & A/c IncApplicant: Antonio Andrade-calzadaFees: $81Effective Date: 2012-04-16Permit Number: 5138283
August 31, 2010
Description: Window replace an existing window with like/kind - no change to the existing rough opening size how many windows are being replaced?___18___ r310.1.5 replacement windows. Replacement windows installed in buildings meeting the scope of the international residential code shall be exempt from the requirements of sections r310.1.1 r310.1.2 and r310.1.3 if the replacement window meets the following conditions: 1. The existing height and width net clear opening shall not be reduced by more than 2 inches (51 mm) in either dimension; 2. The rooms or areas are not used for any minnesota state licensed purpose; 3. The window is not required pursuant to the minnesota fire code; 4. The sleeping room is not undergoing an addition remodeling or a change in occupancy; and 5. The window meets the provisions of the minneapolis housing maintenance codeStatus: finalType: ResidentialApplicant: Antonio Andrade CalzadaEffective Date: 2010-08-31Permit Number: BLDG103818
July 24, 2009
Description: Mechanical mechanical | warm air heating systems | scope of work: ventillation - bathroom fan carbon monoxide detectors are required in dwelling units in accordance with minnesota statute 299f.50. Please refer to the following website for additional information. Http://www.doli.state.mn.us/pdf/bcs_co_detectors_joint_memo_july06.pdf HVAC equipment is allowed as a permitted obstruction in a required side or rear yard as follows: air-conditioning systems heating ventilating and filtering equipment not to exceed four (4) feet in height and adjacent to a nonresidential use or adjacent to a residential use which is equipped with central air conditioning or which has no windows or doors in the wall immediately abutting the yard. Such equipment may project into a corner side yard provided such equipment is located no closer than three (3) feet from the corner side lot line. In no case shall any permitted obstruction be located closer than one (1) foot from the property line. If you have any quStatus: finalType: MechanicalApplicant: Antonio Andrade CalzadaEffective Date: 2009-07-24Permit Number: BLDG310789
July 6, 2009
Description: Ventillation - bathroom fanStatus: DoneType: MechanicalSub Type: BtmaBusiness Name: Valmer, IncApplicant: Antonio Andrade-calzadaFees: $70Effective Date: 2009-07-06Permit Number: 4083444
May 28, 2009
Description: Install gibson brand 80000 btu furnace. Heat loss sheet(s) attached to application filed in inspections officeStatus: DoneType: MechanicalSub Type: BtmaBusiness Name: Royalton Heating & CoolingApplicant: Antonio Andrade-calzadaFees: $102Effective Date: 2009-05-28Permit Number: 4082623
January 10, 2008
Description: DET GAR Construct detached 21' by 22' wood frame garage. AAA. GENERAL COMMENTS: APPLICANT MUST LOCATE AND IDENTIFY THE PROPERTY STAKES AND CALL FOR INSPECTION FOR BUILDING INSPECTOR VERIFICATION BEFORE CONCRETE IS POURED. APPROVED SITE PLAN AND PERMIT MUST BE ON SITE BEFORE INSPECTIONS WILL BE PROVIDED. SEPARATE ELECTRICAL AND MECHANICAL PERMITS REQUIRED FOR ELECTRICAL AND MECHANICAL WORK. Walls, soffits, and fascia closer than 3 feet to property lines not adjacent to public right-of-ways must be protected on the interior and exterior face with 5/8" exterior gypsum sheathing, stucco or other approved materials for fire resistance. Openings (windows, etc.) are not permitted in walls closer than 3 feet to property lines not adjacent to public right-of-ways. 12 ft. maximum average roof height Eaves are not permitted to extend closer than 6 in. to property line Anchor bolts must be within 12 in. of each end of each piece of plate and 6 ft. on center maximum Truss diagrams must be availableJob Value: $10,214Status: completeType: ResidentialBusiness Name: Antonio Andrade CalzadaApplicant: Antonio Andrade CalzadaEffective Date: 2008-01-10Permit Number: BLDG48440
September 12, 2007
Description: Replace an existing window with like/kind - no change to the existing rough opening sizeStatus: DoneType: Building over the counterSub Type: BotcBusiness Name: Sustainable Resources CtrApplicant: Antonio Andrade-calzadaFees: $115Effective Date: 2007-09-12Permit Number: 1071042
July 26, 2004
Description: Wire new garageStatus: DoneType: ElectricalSub Type: BteaBusiness Name: Antonio AndradeApplicant: Antonio Andrade-calzadaFees: $56Effective Date: 2004-07-26Permit Number: 1069236
April 14, 2004
Description: Construct detached 21 by 22 wood frame garage. AaaJob Value: $10,215Status: DoneType: RemodelingSub Type: BireBusiness Name: Antonio Andrade-calzadaApplicant: Antonio Andrade-calzadaFees: $212Effective Date: 2004-04-14Permit Number: 3027393
May 7, 2001
Description: plumbing1 wc 1 sw 1 bn basement bathroomStatus: finalType: PlumbingApplicant: Antonio Andrade CalzadaEffective Date: 2001-05-07Permit Number: BLDG552653
March 9, 2001
Description: R3/REM BATHROOM REMODEL IN BASEMENT, NEW BATHROOM FIXTURES , WALLS AND TILES. bOTTOM PLATE OF THE WALL MUST BE TREATED LUMBER. AAA.Job Value: $1,000Status: completeType: ResidentialBusiness Name: Antonio Andrade CalzadaApplicant: Antonio Andrade CalzadaEffective Date: 2001-03-09Permit Number: BLDG177839
January 23, 2001
Description: Gfi outlet exhaust fan wall lighting for cabinet basement bathroomStatus: DoneType: ElectricalSub Type: BteaBusiness Name: Antonio AndradeApplicant: Antonio Andrade-calzadaFees: $41Effective Date: 2001-01-23Permit Number: 1028622
January 23, 2001
Description: 1 wc 1 sw 1 bn basement bathroomStatus: DoneType: plumbingSub Type: BtpaBusiness Name: Antonio C. AndradeApplicant: Antonio Andrade-calzadaFees: $70Effective Date: 2001-01-23Permit Number: 5018529
January 22, 2001
Description: Bathroom remodel in basement new bathroom fixtures walls and tiles. Bottom plate of the wall must be treated lumber. AaaJob Value: $1,000Status: DoneType: Building over the counterSub Type: BotcBusiness Name: Antonio Andrade-calzadaApplicant: Antonio Andrade-calzadaFees: $39Effective Date: 2001-01-22Permit Number: 1032143
January 1, 1900
Description: Tear-off & replace roof on houseJob Value: $3,200Status: completeType: ResidentialBusiness Name: Bayport Roofing & Siding LLCApplicant: Antonio Andrade CalzadaFees: $144Effective Date: 1900-01-01Permit Number: BLDG773709
January 1, 1900
Description: Mechanical mechanical | warm air heating systems | scope of work: install gibson brand 80000 btu furnace. Heat loss sheet(s) attached to application filed in inspections office. Carbon monoxide detectors are required in dwelling units in accordance with minnesota statute 299f.50. Please refer to the following website for additional information. Http://www.doli.state.mn.us/pdf/bcs_co_detectors_joint_memo_july06.pdf HVAC equipment is allowed as a permitted obstruction in a required side or rear yard as follows: air-conditioning systems heating ventilating and filtering equipment not to exceed four (4) feet in height and adjacent to a nonresidential use or adjacent to a residential use which is equipped with central air conditioning or which has no windows or doors in the wall immediately abutting the yard. Such equipment may project into a corner side yard provided such equipment is located no closer than three (3) feet from the corner side lot line. In no case shall any permitted obstruStatus: completeType: MechanicalBusiness Name: Royalton Heating & CoolingApplicant: Antonio Andrade CalzadaEffective Date: 1900-01-01Permit Number: BLDG323871

Current Ownership

Information about the current owner(s).

Property History

3215 S 19th Ave has undefined property events records (listings, deeds, permits, tax, foreclosure, loan).

Property Events

Environment

Environmental factors around 3215 S 19th Ave

School Information

Public/private schools serving 3215 S 19th Ave

Neighborhood

This property is located in Corcoran, Minneapolis, MN 55407.

Market Trends

Historical market data near 3215 S 19th Ave over selected time period.

Nearby Properties on 19th Ave