3115 47th St, Minneapolis, MN 55410 is a 3 bed, 1 bath, 1,276 ft² house built in 1914 on a 0.130 acre lot with 45 construction permits. This house is currently off market, and it was last sold in 2019 for $520,500. The latest TopHap estimate of the house's value is $531,357.

Property Valuations

Latest estimates for 3115 47th St based on TopHap automated valuation model (AVM).

Permits

3115 47th St has 45 permit records of total value of $314,298.

Permit History
45
Permits
$314,298
Total Permit Value
June 6, 2022
Description: Water heaterStatus: issuedType: plumbingBusiness Name: Roto Rooter Services COApplicant: Rebecca L HutingFees: $85Effective Date: 2022-06-06Permit Number: BLDG948124
October 7, 2019
Description: Replace furnaceStatus: issuedType: MechanicalBusiness Name: Uptown Plumbing Heating & CoolingApplicant: Rebecca L HutingFees: $133Effective Date: 2019-10-07Permit Number: BLDG797667
March 28, 2019
Description: ductless mini splitStatus: completeType: MechanicalBusiness Name: Sedgwick Heating & Air Conditioning LlcApplicant: Rebecca L HutingFees: $82Effective Date: 2019-03-28Permit Number: BLDG662701
March 28, 2019
Description: Replace gas dryerStatus: completeType: plumbingBusiness Name: Warners Stellian CO INCApplicant: Rebecca L HutingFees: $84Effective Date: 2019-03-28Permit Number: BLDG754905
March 28, 2019
Description: Replace 12 windows replace 12 windowsJob Value: $9,000Status: completeType: ResidentialBusiness Name: Vujovich Design Build INCApplicant: Peter W Rainey; Rebecca L HutingFees: $243Effective Date: 2019-03-28Permit Number: BLDG624344
March 28, 2019
Description: Install 2.5 ton central air conditioningStatus: completeType: MechanicalBusiness Name: Sedgwick Heating & AIR ConditioningApplicant: Rebecca L HutingEffective Date: 2019-03-28Permit Number: BLDG695105
March 26, 2018
Project Name: SHADescription: Replace air conditioningStatus: finalType: Ele exst 1 or 2 familyBusiness Name: Powerhouse Electric IncApplicant: RaineyFees: $36Effective Date: 2018-03-26Permit Number: ELE1802-03676
January 25, 2017
Description: RaineyStatus: FINALEDType: Ele exst 1 or 2 familyBusiness Name: JZ ELECTRIC INCApplicant: RaineyFees: $36Effective Date: 2017-01-25Permit Number: ELE1701-05652
November 8, 2016
Description: Gas fix install gas fireplace insert. _______________________________________ gas fixture replace/install - is this a new install(y/n)?____ - is this a replacement(y/n)?____ - fireplace(y/n)?___ - stove(y/n)?____ - dryer(y/n)?____ - water heater(y/n)?____ - gas grill(y/n)?____ - other: describe below carbon monoxide detectors are required in dwelling units in accordance with minnesota statute 299f.50. Please refer to the following website for additional information. Https://www.revisor.mn.gov/statutes/?id=299f.51Status: completeType: plumbingBusiness Name: Master GAS Fitters INCApplicant: Peter W Rainey; Rebecca L Huting0Effective Date: 2016-11-08Permit Number: BLDG554658
November 2, 2016
Description: Install gas fireplace insertStatus: DoneType: plumbingSub Type: BtpaBusiness Name: Master Gas Fitters IncApplicant: Peter W RaineyFees: $82Effective Date: 2016-11-02Permit Number: 5199101
August 20, 2015
Project Name: 129795 - RaineyDescription: Storm repair - meter/mastStatus: finalType: Ele exst 1 or 2 familyBusiness Name: Harrison Electric INCApplicant: Peter RaineyFees: $36Effective Date: 2015-08-20Permit Number: ELE1507-09321
December 29, 2014
Description: *irc4-newJob Value: $19,000Status: completeType: ResidentialBusiness Name: Minneapolis Garage Builders LLCApplicant: Peter W Rainey; Rebecca L Huting0Effective Date: 2014-12-29Permit Number: BLDG68311
December 29, 2014
Description: *irc1-r/r construct 16 x 15 treated wood deck at rear yard of single family dwelling with 2 x 10 joists (dmh#2) (2) 2x 10 beams guardrail stairs handrail treated wood posts and 4 footing locations. Grippable handrail height 34"-38 above nose of tread required at 4 or more risers. 7 3/4 maximum rise 10 minimum tread allowed at stairs. 36 minimum guardrail height and less than 4 space required when 30 or more above grade. Frost footing depth minimum 42 below grade. Separate permits are required for electrical plumbing and heating/air conditioning/ventilation work. Carbon monoxide alarms required in accordance with mn. Stat. 299f.50 irc 313.2.1. When interior alterations repairs or additions require a building permit or when one or more sleeping rooms are added or created in existing dwellings smoke detection shall be installed: a. On each level of the house b. In each bedroom c. In the hall or room outside of bedrooms. Exceptions: 1. Smoke alarms in existing areas shall not be required tJob Value: $7,000Status: completeType: ResidentialBusiness Name: Fencein Deck LLCApplicant: Peter W Rainey; Rebecca L Huting0Effective Date: 2014-12-29Permit Number: BLDG69238
December 29, 2014
Description: *irc1-r/r remodel kitchen and 2nd floor bathroom to single family dwelling. Gut existing finishes demolish (dmh#2) non-bearing walls and modify bathroom layout. Demolish non bearing wall at main floor between living room and sunroom. Install insulation and vapor barrier at exterior wall conditions. Install cement backer board for ceramic tile at tub/shower locations and drywall finishes elsewhere. Replace bathroom window in same opening. Separate permits are required for electrical plumbing and heating/air conditioning/ventilation work. Carbon monoxide alarms required in accordance with mn. Stat. 299f.50 smoke detectors and carbon monoxide detectors shall be installed and operable at the time the building inspector performs the final inspection for this permit. Irc 313.2.1. When interior alterations repairs or additions require a building permit or when one or more sleeping rooms are added or created in existing dwellings smoke detection shall be installed: a. On each level of the housJob Value: $85,000Status: completeType: ResidentialBusiness Name: Vujovich Design Build INCApplicant: Peter W Rainey; Rebecca L Huting0Effective Date: 2014-12-29Permit Number: BLDG47756
December 29, 2014
Description: GAS FIX 1 GAS LINE TO RANGE, 40,000 BTU Gas fixture replace/install - Is this a new install(y/n)?_N___ - Is this a replacement(y/n)?_Y___ - Fireplace(y/n)?__N_ - Stove(y/n)?__Y__ - Dryer(y/n)?_N__ - Water Heater(y/n)?___N_ - Gas grill(y/n)?__N__ - Other: describe below Carbon monoxide detectors are required in dwelling units in accordance with Minnesota Statute 299F.50. Please refer to the following website for additional information. http://www.dli.mn.gov/ccld/PDF/bc_websmoke_co_06_07.pdfStatus: completeType: PlumbingBusiness Name: Binder Heating & AIR Conditioning INCApplicant: Rebecca L Huting0Effective Date: 2014-12-29Permit Number: BLDG575572
December 29, 2014
Description: plumbing fix 1 gas appliance and the following fixtures; specify the type of fixtures by entering the quantity in the list below: water closets__1__ urinals_____ bathroom tubs____ basins__2__ sinks___1__ wash trays_____ showers___1__ floor drains____ extensions_____ misc fixtures__3 (ice maker dishwasher disposal__ electric water heaters_____ other: specify below properly plug the unused plumbing openings at the nearest live main or branch on the waste and vent system. Cement is not an acceptable method of disconnect. Approved plumbing materials must be used. Dead ends are not permitted except where necessary to extend piping for a cleanout so as to be accessible. The work must be done by a licensed plumbing contractor in which a permit and inspection is required before concealing. Carbon monoxide detectors are required in dwelling units in accordance with minnesota statute 299f.50. Please refer to the following website for additional information. Http://www.dli.mn.gov/ccld/pdf/bc_websStatus: completeType: plumbingBusiness Name: Stewart Plumbing INCApplicant: Peter W Rainey; Rebecca L Huting0Effective Date: 2014-12-29Permit Number: BLDG520937
December 25, 2014
Project Name: Vuj/raineyDescription: Kitchen remodelStatus: finalType: Ele exst 1 or 2 familySub Type: Residential exstBusiness Name: JZ Electric INCApplicant: Pete RainyFees: $110Effective Date: 2014-12-25Permit Number: ELE1410-03683
December 16, 2014
Description: HVAC-LVL1 | Scope of work: MISCELLANEOUS HVAC WORK (NO BURNERS) Identify mechanical work of the existing individual heating/cooling system that serves an individual dwelling unit. Indicate the number of systems that apply: __ Radiation piping for space heating* __ Supplies and returns (4 openings or less) __ Fresh air intake, air cleaner, humidifier, venting, fans, gas piping (heating systems only), radon mitigation, and other accessories __ Air conditioner add-on or replacement** __ Solid fuel heating devices (wood, pellets, etc.) SUPPLIES AND RETURNS IN THE ADDITION, VENT BATH AND KITCHEN EXHAUST REQUIRED FOR INSPECTION 1. All work done under this permit must be completed by a person with the proper Minneapolis installer competency card employed by the Minneapolis licensed permit applicant. *Homeowners applying for in-floor heating must be approved by the Mechanical Reviewer ** HVAC equipment is allowed as a permitted obstruction in a required side or rear yard only when zoning code Status: completeType: MechanicalBusiness Name: Binder Heating & AIR Conditioning INCApplicant: Rebecca L Huting0Effective Date: 2014-12-16Permit Number: BLDG358362
October 29, 2014
Job Value: $5,250Status: completeType: ResidentialBusiness Name: Think StuccoApplicant: Rebecca L HutingEffective Date: 2014-10-29Permit Number: BLDG131735
October 23, 2014
Description: PLUMB M0VE METER FROM INSIDE TO OUTSIDE Properly plug the unused plumbing openings at the nearest live main or branch on the waste and vent system. Cement is not an acceptable method of disconnect. Approved plumbing materials must be used. Dead ends are not permitted except where necessary to extend piping for a cleanout so as to be accessible. The work must be done by a licensed plumbing contractor in which a permit and inspection is required before concealing. Carbon monoxide detectors are required in dwelling units in accordance with Minnesota Statute 299F.50. Please refer to the following website for additional information. http://www.doli.state.mn.us/pdf/bcs_co_detectors_joint_memo_july06.pdf Plans approved by both the State of Minnesota Department of Health and the Department of Labor and Industry are required to be on site for all plumbing work conducted in hospitals, nursing homes, supervised living facilities, outpatient surgical centers, boarding care homes, and residential hStatus: completeType: PlumbingBusiness Name: Center Point EnergyApplicant: Peter W Rainey; Rebecca L Huting0Effective Date: 2014-10-23Permit Number: BLDG507190
October 23, 2014
Description: plumbing fix pvb's for irrigation one in front one in back ( not rpz just backflow) specify the type of fixtures by entering the quantity in the list below: water closets____ urinals_____ bathroom tubs____ basins____ sinks_____ wash trays_____ showers_____ floor drains____ extensions_____ misc fixtures__2__(backflow) electric water heaters_____ other: specify below properly plug the unused plumbing openings at the nearest live main or branch on the waste and vent system. Cement is not an acceptable method of disconnect. Approved plumbing materials must be used. Dead ends are not permitted except where necessary to extend piping for a cleanout so as to be accessible. The work must be done by a licensed plumbing contractor in which a permit and inspection is required before concealing. Carbon monoxide detectors are required in dwelling units in accordance with minnesota statute 299f.50. Please refer to the following website for additional information. Http://www.dli.mn.gov/ccld/pdf/bc_weStatus: completeType: plumbingBusiness Name: Andersons Prompt Plumbing LLCApplicant: Peter W Rainey; Rebecca L Huting0Effective Date: 2014-10-23Permit Number: BLDG574250
October 10, 2014
Description: 1 gas appliance and the following fixtures;Status: DoneType: plumbingSub Type: BtpaBusiness Name: Stewart PlumbingApplicant: Peter W RaineyFees: $394Effective Date: 2014-10-10Permit Number: 5170786
October 10, 2014
Description: Miscellaneous HVAC work (no burners)Status: DoneType: HVAC alterationsSub Type: BtmbBusiness Name: Binder Heating & Air ConditioningApplicant: Peter W RaineyFees: $86Effective Date: 2014-10-10Permit Number: 4110074
October 6, 2014
Description: 1 gas line to range 40, 000 btuStatus: DoneType: plumbingSub Type: BtpaBusiness Name: Binder Heating & Air ConditioningApplicant: Peter W RaineyFees: $86Effective Date: 2014-10-06Permit Number: 5170615
September 24, 2014
Description: Remodel kitchen and 2nd floor bathroom to single family dwelling. Gut existing finishes demolish (dmh#2)Job Value: $85,000Status: DoneType: RemodelingSub Type: BireBusiness Name: Vujovich Design-build, IncApplicant: Peter W RaineyFees: $1,467Effective Date: 2014-09-24Permit Number: 3093893
July 30, 2014
Description: Pvb's for irrigation one in front one in back ( not rpz just backflow)Status: DoneType: plumbingSub Type: BtpaBusiness Name: Andersons Prompt Plumbing LlcApplicant: Peter W RaineyFees: $86Effective Date: 2014-07-30Permit Number: 5167953
May 17, 2013
Description: Construct 16 x 15 treated wood deck at rear yard of single family dwelling with 2 x 10 joists (dmh#2)Job Value: $7,000Status: DoneType: RemodelingSub Type: BireBusiness Name: Fencein Deck LlcApplicant: Peter W RaineyFees: $322Effective Date: 2013-05-17Permit Number: 3084497
March 28, 2013
Description: Stucco new garage:apply moisture barrier heavy galv metal lath and stucco to new garage including stops and screedsStatus: DoneType: Building over the counterSub Type: BotcBusiness Name: Think StuccoApplicant: Peter W RaineyFees: $172Effective Date: 2013-03-28Permit Number: 1108235
March 26, 2013
Description: Water htr replace existing water heater - is this a gas water heater(y/n)?__y_ - is this an electric water heater(y/n)?__ note: an electric water heater replacement also requires an electrical permit - other: describe below carbon monoxide detectors are required in dwelling units in accordance with minnesota statute 299f.50. Please refer to the following website for additional information. Http://www.doli.state.mn.us/pdf/bcs_co_detectors_joint_memo_july06.pdfStatus: completeType: plumbingBusiness Name: Norblom PlumbingApplicant: Peter W Rainey; Rebecca L Huting0Effective Date: 2013-03-26Permit Number: BLDG467072
November 30, 2012
Project Name: Pete Rainy GarageDescription: Garage w existing circuitStatus: finalType: Ele exst 1 or 2 familySub Type: Residential exstBusiness Name: Dependable Electric INCApplicant: Pete RainyFees: $75Effective Date: 2012-11-30Permit Number: ELE1211-02442
September 25, 2012
Description: Construct detached _18'__ by _26'__ wood frame garage at single family dwelling (maa #02)Job Value: $19,000Status: DoneType: RemodelingSub Type: BireBusiness Name: Minneapolis Garage Builders LlcApplicant: Peter W RaineyFees: $420Effective Date: 2012-09-25Permit Number: 3080915
July 20, 2011
Description: Reroof tearoff and reroof house only all exterior work to be completed within one year of permit issuance date per minneapolis city ordinance 89.165 all roof drains area drains or other stormwater or clearwater connections to the city's sanitary sewer system must be disconnected per chapter 56 of the minneapolis code of ordinances. Contact arvella greenway at 612 673 5899 if you questions. Carbon monoxide detectors are required in dwelling units in accordance with minnesota statute 299f.50. Please refer to the following website for additional information. Http://www.doli.state.mn.us/pdf/bcs_co_detectors_joint_memo_july06.pdfJob Value: $4,480Status: completeType: ResidentialBusiness Name: Wright AT Home Services INCApplicant: Peter W Rainey; Rebecca L Huting0Effective Date: 2011-07-20Permit Number: BLDG119177
July 13, 2011
Description: Tearoff and reroof house onlyJob Value: $4,480Status: DoneType: Building over the counterSub Type: BotcBusiness Name: Wright At Home Services IncApplicant: Peter W RaineyFees: $149Effective Date: 2011-07-13Permit Number: 1095284
March 7, 2011
Description: M0ve meter from inside to outsideStatus: DoneType: plumbingSub Type: BtpaBusiness Name: Centerpoint EnergyApplicant: Peter W RaineyFees: $77Effective Date: 2011-03-07Permit Number: 5126466
February 25, 2010
Description: Mas/concrt repair/replace exterior brick veneer or chimney type of work: - brick chimney (y/n)?____ - brick structure facade (y/n)?____ - other: describe below remove & rebuild upper section of chimney M.C.O. 89.165 completion of work - all work for altering repairing or remodeling the exterior portion of a single-family dwelling or two-family dwelling including an attached or detached garage shall be completed within one 1) year from the date of issuance of the building permitJob Value: $890Status: completeType: ResidentialBusiness Name: Metro Chimney Mansonry INCApplicant: Peter W Rainey; Rebecca L Huting0Effective Date: 2010-02-25Permit Number: BLDG104072
February 24, 2010
Description: Replace existing water heaterStatus: DoneType: plumbingSub Type: BtpaBusiness Name: Norblom PlumbingApplicant: Peter W RaineyFees: $70Effective Date: 2010-02-24Permit Number: 5113631
March 31, 2008
Description: Repair/replace exterior brick veneer or chimneyJob Value: $890Status: DoneType: Building over the counterSub Type: BotcBusiness Name: Metro Chimney Mansonry, IncApplicant: Peter W RaineyFees: $64Effective Date: 2008-03-31Permit Number: 1073138
March 17, 2006
Description: Install york brand 60 mbh furnaceJob Value: $3,218Status: DoneType: MechanicalSub Type: BtmaBusiness Name: Standard Htg & A/c CoApplicant: Peter W RaineyFees: $104Effective Date: 2006-03-17Permit Number: 4059618
March 17, 2006
Description: Mechanical mechanical | scope of work: install york brand 60 mbh furnace pete rainey 929-2400 mechanical | warm air heating systems | scope of work: install york brand 60 mbh furnace pete rainey 929-2400 mechanical | scope of work: install york brand 60 mbh furnace pete rainey 929-2400 mechanical | scope of work: install york brand 60 mbh furnace pete rainey 929-2400Status: completeType: Mechanical; Mechanical permitSub Type: MechanicalBusiness Name: Standard Heating &A/C CO; Standard Htg & A / C Co; Standard Htg and A/C CoApplicant: Rebecca L Huting; Peter W Rainey0Effective Date: 2006-03-17Permit Number: BLDG285745
May 26, 2005
Description: Windows install cedar shakes on upper walls of house. Replace front and rear entry doors. Cover soffits and fascia with aluminum. Install new cedar trim around windows and doors. All exterior work to be completed within one year of permit issuance per mpls ordinance 89.165 replace 12 windows r310.1.5 replacement windows. Replacement windows installed in buildings meeting the scope of the international residential code shall be exempt from the requirements of sections r310.1.1 r310.1.2 and r310.1.3 if the replacement window meets the following conditions: 1. The existing height and width net clear opening shall not be reduced by more than 2 inches (51 mm) in either dimension; 2. The rooms or areas are not used for any minnesota state licensed purpose; 3. The window is not required pursuant to the minnesota fire code; 4. The sleeping room is not undergoing an addition remodeling or a change in occupancy; and 5. The window meets the provisions of the minneapolis housing maintenance code (Job Value: $15,395Status: completeType: ResidentialBusiness Name: Exterior Enhancements INCApplicant: Peter W Rainey; Rebecca L Huting0Effective Date: 2005-05-26Permit Number: BLDG91208
November 17, 2004
Description: Install cedar shakes on upper walls of house. Replace front and rear entry doors. Cover soffits and fascia with aluminum. Install new cedar trim around windows and doors. All exterior work to be completed within one year of permit issuance per mpls ordinance 89.165Job Value: $15,395Status: DoneType: Building over the counterSub Type: BotcBusiness Name: Exterior Enhancements IncApplicant: Peter W RaineyFees: $288Effective Date: 2004-11-17Permit Number: 1058200
September 23, 2004
Description: R3/addn construct 7x5 treated wood deck and open porch at front of single family dwelling with (dmh#2) 2 x10 joists (2) 2 x 10 beams 2x6 rafters stairs handrail guardrail posts and 2 footing locations. General comments: *if using plastic decking board see handout list for approved decking manufacturers. Contact gopher state one (651-454-0002) prior to digging footings or foundations. 36 minimum guardrail height and less than 4 spacing vertically for decks/landings at 30 or more above grade. 8 max. Rise and 9 min. Tread for steps. Grippable handrail height at 34''- 38 above nose of tread and required at 4 or more risers. Work completed or omitted in violation of the building code shall be corrected as directed by the building inspector. Required inspections: footing and foundation before placing concrete (if project involves pouring concrete); structural framing; final inspection after all work completedJob Value: $16,000Status: completeType: ResidentialBusiness Name: First Choice Exteriors INCApplicant: Rebecca L HutingEffective Date: 2004-09-23Permit Number: BLDG20624
August 10, 2004
Description: Wire porch 1 cktStatus: DoneType: ElectricalSub Type: BteaBusiness Name: Jatco ElectricApplicant: Peter W RaineyFees: $56Effective Date: 2004-08-10Permit Number: 1069793
July 29, 2004
Description: Construct 7x5 treated wood deck and open porch at front of single family dwelling with (dmh#2)Job Value: $16,000Status: DoneType: RemodelingSub Type: BireBusiness Name: First Choice Exteriors IncApplicant: Peter W RaineyFees: $494Effective Date: 2004-07-29Permit Number: 3030047
July 17, 1998
Description: Instl air conditioning pa p&l=tdJob Value: $1,300Status: DoneType: MechanicalSub Type: QApplicant: Peter W Rainey0Effective Date: 1998-07-17Permit Number: 116807

Current Ownership

Information about the current owner(s).

Property History

3115 47th St has undefined property events records (listings, deeds, permits, tax, foreclosure, loan).

Property Events

Environment

Environmental factors around 3115 47th St

School Information

Public/private schools serving 3115 47th St