2954 N Bryant Ave, Minneapolis, MN 55411 is a 3 bed, 2 bath, 1,750 ft² house built in 1912 on a 0.120 acre lot with 39 construction permits. This house is currently off market, and it was last sold in 2018. The latest TopHap estimate of the house's value is $186,114.

Property Valuations

Latest estimates for 2954 N Bryant Ave based on TopHap automated valuation model (AVM).

Permits

2954 N Bryant Ave has 39 permit records of total value of $104,873.

Permit History
39
Permits
$104,873
Total Permit Value
June 8, 2016
Description: PLUMB 1 BASIN, 1 FLOORDRAIN, 1 SHOWER, 1 SINK, 1 LAUNDRY TUB, 1 TOILET, RESSESED WASHER BOXED Properly plug the unused plumbing openings at the nearest live main or branch on the waste and vent system. Cement is not an acceptable method of disconnect. Approved plumbing materials must be used. Dead ends are not permitted except where necessary to extend piping for a cleanout so as to be accessible. The work must be done by a licensed plumbing contractor in which a permit and inspection is required before concealing. Carbon monoxide detectors are required in dwelling units in accordance with Minnesota Statute 299F.50. Please refer to the following website for additional information. http://www.doli.state.mn.us/pdf/bcs_co_detectors_joint_memo_july06.pdf Plans approved by both the State of Minnesota Department of Health and the Department of Labor and Industry are required to be on site for all plumbing work conducted in hospitals, nursing homes, supervised living facilities, outpatient suStatus: finalType: PlumbingApplicant: Joseph GarnierEffective Date: 2016-06-08Permit Number: BLDG499218
June 8, 2016
Description: PLUM FIX Specify the type of fixtures by entering the quantity in the list below: Water Closets____ Urinals_____ Bath Tubs____ Basins____ Sinks__1___ Wash Trays_____ Showers_____ Floor Drains____ Extensions_____ Misc Fixtures_1 ice maker, 1 dishwasher, 1 disposal, 1 pot filler Electric Water Heaters_____ Other: Specify below Properly plug the unused plumbing openings at the nearest live main or branch on the waste and vent system. Cement is not an acceptable method of disconnect. Approved plumbing materials must be used. Dead ends are not permitted except where necessary to extend piping for a cleanout so as to be accessible. The work must be done by a licensed plumbing contractor in which a permit and inspection is required before concealing. Carbon monoxide detectors are required in dwelling units in accordance with Minnesota Statute 299F.50. Please refer to the following website for additional information. http://www.doli.state.mn.us/pdf/bcs_co_detectors_joint_memo_july06.pdf Plans Status: finalType: PlumbingApplicant: Joseph GarnierEffective Date: 2016-06-08Permit Number: BLDG486336
December 17, 2012
Project Name: Meter MastStatus: finalType: Ele exst 1 or 2 familySub Type: Residential exstBusiness Name: Global Green ElectricalApplicant: DriFees: $40Effective Date: 2012-12-17Permit Number: ELE1203-05618
December 17, 2012
Project Name: NoteDescription: (6/24/2011 2:20 pm dpp) basement washer dryer combo dedicated 15 amp 15 amp bathroom shower light fan heater one outlet 15 amp gfci bathroom floor tile heater overhead light vanity light vanity gfci outlet 20 amp outlets center of basement & HVAC room light in HVAC room addition 8 recessed lights on current circuit 15 amp gfci outles x3 dedicated 15 amp outlet relocate dedicated dishwasher outlet 15 amp gfci with 3 outlets dedicated disposal outlet dedicated microwave outlet 15 amp circuit for refrigerator and wine chiller relocate range circuit 40 amp 15 amp 4 outlets and low voltage lightingStatus: finalType: Ele exst 1 or 2 familySub Type: Residential exstApplicant: Joseph GarnierFees: $140Effective Date: 2012-12-17Permit Number: ELE1106-17889
February 9, 2012
Project Name: Saver SwitchStatus: finalType: Ele exst 1 or 2 familySub Type: Residential exstBusiness Name: Hunt Electric CorporationApplicant: Joseph GarnierFees: $40Effective Date: 2012-02-09Permit Number: ELE1202-04842
June 3, 2011
Description: Replace kitchen window and open 4 ft wide passage in bearing wall (th-#2)Job Value: $1,700Status: DoneType: RemodelingSub Type: BireBusiness Name: Joseph GarnierApplicant: Joseph D GarnierFees: $113Effective Date: 2011-06-03Permit Number: 3071668
June 3, 2011
Description: *IRC1-R/R REPLACE KITCHEN WINDOW AND OPEN 4 FT WIDE PASSAGE IN BEARING WALL (TH-#2) OWNER TO USE MICROLAM HEADER, FRAMING INSPECTION REQUIRED. SEPARATE PERMITS ARE REQUIRED FOR ELECTRICAL, PLUMBING, AND HEATING/AIR CONDITIONING/VENTILATION WORK. CARBON MONOXIDE ALARMS REQUIRED IN ACCORDANCE WITH MN. STAT. 299F.50 IRC 313.2.1. When interior alterations, repairs or additions require a building permit or when one or more sleeping rooms are added or created in existing dwellings, smoke detection shall be installed: A. on each level of the house B. in each bedroom C. in the hall or room outside of bedrooms. Exceptions: 1. Smoke alarms in existing areas shall not be required to be interconnected and hardwired where the alterations or repairs do not result in the removal of interior wall or ceiling finishes exposing the structure, unless there is a crawl space or basement available which could provide access for hardwiring and interconnection without the removal of interior finishes. 2. Work Status: finalType: ResidentialApplicant: Joseph GarnierEffective Date: 2011-06-03Permit Number: BLDG35710
May 18, 2011
Description: Specify the type of fixtures by entering the quantity in the list below:Status: OpenType: plumbingSub Type: BtpaBusiness Name: Joseph GarnierApplicant: Joseph D GarnierFees: $187Effective Date: 2011-05-18Permit Number: 5128607
May 10, 2011
Description: *irc4-newStatus: finalType: ResidentialApplicant: Joseph GarnierEffective Date: 2011-05-10Permit Number: BLDG42378
April 27, 2011
Description: MECH | Scope of work: rough in a 3/2 gas line for future 2 psi meter change rugh in only Carbon monoxide detectors are required in dwelling units in accordance with Minnesota Statute 299F.50. Please refer to the following website for additional information. http://www.doli.state.mn.us/pdf/bcs_co_detectors_joint_memo_july06.pdf HVAC equipment is allowed as a permitted obstruction in a required side or rear yard as follows: Air-conditioning systems, heating, ventilating, and filtering equipment, not to exceed four (4) feet in height and adjacent to a nonresidential use or adjacent to a residential use which is equipped with central air conditioning or which has no windows or doors in the wall immediately abutting the yard. Such equipment may project into a corner side yard, provided such equipment is located no closer than three (3) feet from the corner side lot line. In no case shall any permitted obstruction be located closer than one (1) foot from the property line. If you have any quStatus: finalType: MechanicalBusiness Name: In A Vent Heating & Air Conditioning LlcApplicant: Joseph GarnierEffective Date: 2011-04-27Permit Number: BLDG318044
April 25, 2011
Description: Rough in a 3/2 gas line for future 2 psi meter change rugh in onlyStatus: DoneType: MechanicalSub Type: BtmaBusiness Name: In-a-vent Heating & Air Conditioning LlcApplicant: Joseph D GarnierFees: $74Effective Date: 2011-04-25Permit Number: 4098135
April 11, 2011
Description: Construct detached 20'0 by 22'0 wood frame garage using existing concrete slab. Aaj#2Job Value: $10,953Status: DoneType: RemodelingSub Type: BireBusiness Name: Mn Superior ExteriorsApplicant: Joseph D GarnierFees: $261Effective Date: 2011-04-11Permit Number: 3070516
March 18, 2011
Description: Partial basment finish to single family dwelling for new 3/4 bathroom and open family room finish. (dmh#2)Job Value: $5,000Status: DoneType: RemodelingSub Type: BireBusiness Name: Joseph GarnierApplicant: Joseph D GarnierFees: $215Effective Date: 2011-03-18Permit Number: 3070181
January 5, 2011
Description: 1 basin 1 floordrain 1 shower 1 sink 1 laundry tub 1 toilet ressesed washer boxedStatus: OpenType: plumbingSub Type: BtpaBusiness Name: Joseph GarnierApplicant: Joseph D GarnierFees: $217Effective Date: 2011-01-05Permit Number: 5124769
December 8, 2010
Description: *IRC1-R/R ADD 10' X 6' BATHROOM IN THE BASEMENT AND BUILD 20'X22' GARAGE AT SFD (MAA #02) ******ANY WORK OTHER THAN THE SCOPE ABOVE WILL REQUIRE A SEPARATE BUKDING PERMIT*********** SEPARATE PERMITS ARE REQUIRED FOR ELECTRICAL, PLUMBING, AND HEATING/AIR CONDITIONING/VENTILATION WORK. CARBON MONOXIDE ALARMS REQUIRED IN ACCORDANCE WITH MN. STAT. 299F.50 IRC 313.2.1. When interior alterations, repairs or additions require a building permit or when one or more sleeping rooms are added or created in existing dwellings, smoke detection shall be installed: A. on each level of the house B. in each bedroom C. in the hall or room outside of bedrooms. Exceptions: 1. Smoke alarms in existing areas shall not be required to be interconnected and hardwired where the alterations or repairs do not result in the removal of interior wall or ceiling finishes exposing the structure, unless there is a crawl space or basement available which could provide access for hardwiring and interconnection without theStatus: finalType: ResidentialApplicant: Joseph GarnierEffective Date: 2010-12-08Permit Number: BLDG49845
October 14, 2010
Description: MECH MECH | WARM AIR HEATING SYSTEMS | Scope of work: A/C Carbon monoxide detectors are required in dwelling units in accordance with Minnesota Statute 299F.50. Please refer to the following website for additional information. http://www.doli.state.mn.us/pdf/bcs_co_detectors_joint_memo_july06.pdf HVAC equipment is allowed as a permitted obstruction in a required side or rear yard as follows: Air-conditioning systems, heating, ventilating, and filtering equipment, not to exceed four (4) feet in height and adjacent to a nonresidential use or adjacent to a residential use which is equipped with central air conditioning or which has no windows or doors in the wall immediately abutting the yard. Such equipment may project into a corner side yard, provided such equipment is located no closer than three (3) feet from the corner side lot line. In no case shall any permitted obstruction be located closer than one (1) foot from the property line. If you have any questions, please call 311 or (61Status: finalType: MechanicalBusiness Name: In A Vent Heating & Air Conditioning LlcApplicant: Joseph GarnierEffective Date: 2010-10-14Permit Number: BLDG328052
August 19, 2010
Description: Specify the type of fixtures by entering the quantity in the list below:Status: DoneType: plumbingSub Type: BtpaBusiness Name: Tschida Bros. PlumbingApplicant: Joseph D GarnierFees: $111Effective Date: 2010-08-19Permit Number: 5119612
August 19, 2010
Description: Specify the type of fixtures by entering the quantity in the list below: Water Closets___1_ Urinals_____ Bath Tubs____ Basins__1__ Sinks_____ Wash Trays_____ Showers_____ Floor Drains____ Extensions_____ Misc Fixtures__1__ Electric Water Heaters_____ Other: Specify below Properly plug the unused plumbing openings at the nearest live main or branch on the waste and vent system. Cement is not an acceptable method of disconnect. Approved plumbing materiaStatus: ClosedType: Plumbing PermitSub Type: PlumbingBusiness Name: TSCHIDA BROTHERS PLUMBING INCApplicant: JOSEPH D GARNIERFees: $111Effective Date: 2010-08-19Permit Number: BLDG492655
July 30, 2010
Description: Addition 10 x 6 bathroom in the basement and building 20'x22 garage at single family dwelling (maa #02)Job Value: $20,000Status: DoneType: RemodelingSub Type: BireBusiness Name: D J Steele Construction IncApplicant: Joseph D GarnierFees: $544Effective Date: 2010-07-30Permit Number: 3066555
July 2, 2010
Description: Air conditioningStatus: DoneType: MechanicalSub Type: BtmaBusiness Name: In-a-vent Heating And Air Conditioning, LlcApplicant: Joseph D GarnierFees: $150Effective Date: 2010-07-02Permit Number: 4091872
October 16, 2008
Description: *IRC1-R/R BASEMENT REMODEL & INSTALL VINYL SIDING ON EXTERIOR WALLS OF A SINGLE FAMILY HOUSE. AAJ#2. ***NOTE: NO PLAN SUBMITTED FOR REVIEW. CONTRACTOR PROVIDE DETAILED WORK SPECIFICATIONS AND IS FILED. IF REQUIRED BY FIELD INSPECTOR, PLAN MUST BE SUBMITTED FOR REVIEW.*** - INTERIOR DEMOLITION OF EXISTING BASEMENT. RE-INSULATE PERIMETER WALLS IF NEEDED TO CODE REQUIREMENT. INSTALL DRYWALL ON WALLS ONLY. REPAIR DAMAGED SUSPENDED CEILING. - INSTALL NEW VINYL SIDING ON ALL EXTERIOR WALLS PER MANUFACTURER'S SPECIFICATIONS. SEPARATE PERMITS ARE REQUIRED FOR ELECTRICAL, PLUMBING, AND HEATING/AIR CONDITIONING/VENTILATION WORK. THIS WORK MUST BE COMPLETED BY A LICENSED CONTRACTOR IN A MULTI-FAMILY DWELLING. CARBON MONOXIDE ALARMS REQUIRED IN ACCORDANCE WITH MN. STAT. 299F.50 IRC 313.2.1. When interior alterations, repairs or additions require a building permit or when one or more sleeping rooms are added or created in existing dwellings, smoke detection shall be installed: A. on each level of tStatus: finalType: ResidentialApplicant: Joseph GarnierEffective Date: 2008-10-16Permit Number: BLDG29279
September 22, 2008
Description: MECH MECH | WARM AIR HEATING SYSTEMS | Scope of work: INSTALL COMBUSTION AIR AND REVENT WATER HEATER MECH | Scope of work: INSTALL COMBUSTION AIR AND REVENT WATER HEATER MECH | Scope of work: INSTALL COMBUSTION AIR AND REVENT WATER HEATER MECH | Scope of work: INSTALL COMBUSTION AIR AND REVENT WATER HEATERStatus: finalType: MechanicalBusiness Name: Midland Heating & A / CApplicant: Joseph GarnierEffective Date: 2008-09-22Permit Number: BLDG301418
September 11, 2008
Description: plumbing fix we will properly install new water lines to replace stolen lines install new water closet lavatory sink and tub faucet on second floor replace kitchen sink on first floor and one outdoor silcock. Install new water heater 40, 000 btu and stoveStatus: finalType: plumbingApplicant: Joseph GarnierEffective Date: 2008-09-11Permit Number: BLDG453607
September 4, 2008
Description: Install combustion air and revent water heaterStatus: DoneType: MechanicalSub Type: BtmaBusiness Name: Midland Heating & A/c, IncApplicant: Joseph D GarnierFees: $66Effective Date: 2008-09-04Permit Number: 4077762
August 29, 2008
Description: We will properly install new water lines to replace stolen lines install new water closet lavatory sink and tub faucet on second floor replace kitchen sink on first floor and one outdoor silcock. Install new water heater 40, 000 btu and stoveStatus: DoneType: plumbingSub Type: BtpaBusiness Name: Burnomatic Mooney & RidlerApplicant: Joseph D GarnierFees: $276Effective Date: 2008-08-29Permit Number: 5098429
August 27, 2008
Description: Basement remodel & install vinyl siding on exterior walls of a single family house. Aaj#2Job Value: $10,000Status: DoneType: RemodelingSub Type: BireBusiness Name: Finishing Touch Plus IncApplicant: Joseph D GarnierFees: $221Effective Date: 2008-08-27Permit Number: 3055189
July 3, 2008
Description: Valid for 30 days starting 7/3/08Status: DoneType: Street use permitSub Type: BsuBusiness Name: Big Blue BoxesApplicant: Joseph D GarnierFees: $66Effective Date: 2008-07-03Permit Number: 1023416
December 20, 2006
Description: REROOF TEAROFF AND REROOF HOUSE. All exterior work to be completed within one year of permit issuance date per Minneapolis City Ordinance 89.165 All roof drains, area drains, or other stormwater or clearwater connections to the City's sanitary sewer system must be disconnected per Chapter 56 of the Minneapolis Code of Ordinances. Contact Arvella Greenway at 612 673 5899 if you questions.Status: finalType: ResidentialApplicant: Joseph GarnierEffective Date: 2006-12-20Permit Number: BLDG120596
September 20, 2005
Description: plumbing replace copper water piping in basement gas to water heater set 1 wt and cap gas line to range in ktichen roger chin srStatus: finalType: plumbingApplicant: Joseph GarnierEffective Date: 2005-09-20Permit Number: BLDG444020
September 19, 2005
Description: Replace copper water piping in basement gas to water heater set 1 wt and cap gas line to range in ktichenStatus: DoneType: plumbingSub Type: BtpaBusiness Name: Northeast Plumbing CompanyApplicant: Joseph D GarnierFees: $82Effective Date: 2005-09-19Permit Number: 5068942
July 7, 2005
Description: Tearoff and reroof houseJob Value: $5,000Status: DoneType: Building over the counterSub Type: BotcBusiness Name: Peters, DevikanandApplicant: Joseph D GarnierFees: $124Effective Date: 2005-07-07Permit Number: 1060567
July 7, 2005
Description: Dumpster in street 7/7/05 - 7/15/05Status: DoneType: Street use permitSub Type: BsuBusiness Name: Peters Remodeling & Const Co LlcApplicant: Joseph D GarnierFees: $17Effective Date: 2005-07-07Permit Number: 1017122
April 19, 1993
Description: Rpl 1fd s-1wc gr residenceJob Value: $200Status: DoneType: plumbingSub Type: D0Effective Date: 1993-04-19Permit Number: 921363
January 4, 1993
Description: Rpl 1 100btu gas br residenceStatus: DoneType: Gas burnerSub Type: Qm0Effective Date: 1993-01-04Permit Number: 79795
January 1, 1900
Description: Replace wood siding to vinyl d4Job Value: $10,000Status: filedType: ResidentialBusiness Name: Primetime ContractorsApplicant: Joseph GarnierFees: $274Effective Date: 1900-01-01Permit Number: BLDG952986
January 1, 1900
Description: Install 16 new windows install housewrap exterior insulation and new siding remove and rebuild rear deck and replace deck boards on front porch. Building code: 2020 mnsbc/2018 irc energy code: minnesota rules chapter 1322 separate permits are required for electrical plumbing and heating/air conditioning/ventilation work. Smoke alarms required in accordance with r314 irc 314.3.1. When interior alterations repairs or additions require a building permit or when one or more sleeping rooms are added or created in existing dwellings smoke detection shall be installed: a. On each level of the house b. In each bedroom c. In the hall or room outside of bedrooms. Exceptions: 1. Smoke alarms in existing areas shall not be required to be interconnected and hardwired where the alterations or repairs do not result in the removal of interior wall or ceiling finishes exposing the structure unless there is a crawl space or basement available which could provide access for hardwiring and interconnectionJob Value: $24,700Status: filedType: ResidentialApplicant: Joseph GarnierFees: $778Effective Date: 1900-01-01Permit Number: BLDG922649
January 1, 1900
Description: *irc1-r/r partial basment finish to single family dwelling for new 3/4 bathroom and open family room finish. (dmh#2) install 2x framing cement board at tub/shower locations and drywall finishes elsewhere. Install energy wall along foundation in family room this permit does not approve a basment bedroom existing finishes built without a permit additional dwelling unit or work other than described. Window replacements in rental properties or state licensed facilities must meet the current requirement for egress windows per mnsbc chapter 1309 section r310.1.5 separate permits are required for electrical plumbing and heating/air conditioning/ventilation work. Carbon monoxide alarms required in accordance with mn. Stat. 299f.50 irc 313.2.1. When interior alterations repairs or additions require a building permit or when one or more sleeping rooms are added or created in existing dwellings smoke detection shall be installed: a. On each level of the house b. In each bedroom c. In the hall or Job Value: $5,000Status: completeType: ResidentialBusiness Name: Joseph GarnierApplicant: Joseph GarnierEffective Date: 1900-01-01Permit Number: BLDG31919
January 1, 1900
Description: Tear off small flat roof and replace with pvc flat roof productJob Value: $3,000Status: completeType: ResidentialBusiness Name: MN Superior ExteriorsApplicant: Joseph GarnierFees: $126Effective Date: 1900-01-01Permit Number: BLDG786331
January 1, 1900
Description: Remove and replace shingle roofJob Value: $9,320Status: completeType: ResidentialBusiness Name: Primetime ContractorsApplicant: Joseph GarnierFees: $274Effective Date: 1900-01-01Permit Number: BLDG906859

Current Ownership

Information about the current owner(s).

Property History

2954 N Bryant Ave has undefined property events records (listings, deeds, permits, tax, foreclosure, loan).

Property Events

Environment

Environmental factors around 2954 N Bryant Ave

School Information

Public/private schools serving 2954 N Bryant Ave

Neighborhood

This property is located in Hawthorne, Minneapolis, MN 55411.

Market Trends

Historical market data near 2954 N Bryant Ave over selected time period.

Nearby Properties on Bryant Ave