?
  • Chat with Us
  • Submit Feedback
  • TopHap Academy
  • What's New?
Residential > Condo
Sold
12/17/2019
Sold Price
$425,000$262/ft²

2950 Dean Pkwy 1402
Minneapolis, MN 55416

2950 Dean Pkwy 1402, Minneapolis, MN 55416 is a 2 bed, 2 bath, 1,625 ft² condo built in 1977 with 5 construction permits. This condo is currently off market, and it was last sold in 2019 for $425,000. The latest TopHap estimate of the condo's value is $510,195.

Property Valuations

Latest estimates for 2950 Dean Pkwy 1402 based on TopHap automated valuation model (AVM).

Permits

2950 Dean Pkwy 1402 has 5 permit records.

Permit History
5
Permits
May 27, 2015
Description: *R2-5+R/R INSTALL MIN 32 INCH CLEAR POCKET DOOR AT COMMON WALL BETWEEN SINGLE OWNER UNITS (JAG # 2) ***FIRE/SOUND SEPARATION MUST BE RESTORED PRIOR TO SALE CREATING SEPARATE OWNERSHIP*** CERTIFICATE OF OCCUPANCY REQUIRED: NO CONST TYPE: OCCUPANCY: 2006 IBC SPRINKLERED: YES SPRINKLER TYPE: NFPA 13 FIRE ALARM: YES NO SOUND/FIRE TEST ASSEMBLY____________ ENERGY CODE CHAPTER USED: ELEVATOR REVIEW ________ 20% accessibility upgrades___FULLY_______ Tenant: UNITS 1402 AND 1403 Floor(s): 14TH SAC:NO SAC CREDIT TAKEN. ARCHITECT: ENGINEER: windows with sill heights less than 24 inches above the floor shall be equipped with fall prevention devices that limit the window opening to less than 4 inches in accordance with MSBC 1303.2320 CARBON MONOXIDE ALARMS REQUIRED IN ACCORDANCE WITH MN. STAT. 299F.50 907.2.10 Smoke detection shall be installed: A. on each level of the unit B. in each bedroom C. in the hall or room outside of bedrooms. 907.2.10.2 Power source. In new construction [and units added tStatus: finalType: CommercialEffective Date: 2015-05-27Permit Number: BLDG238729
November 26, 2014
Description: *R2-5+R/R WATER DAMAGE RESTORATION OF EXISTING CONDOMINIUM UNIT #1402 OF AN HIGH RISE BUILDING. AAJ#2. ***NOTE: NO CONSTRUCTION PLAN SUBMITTED FOR REVIEW. COPY OF INSURANCE CLAIM WORK SPECIFICATIONS WORKSHEET IS SUBMITTED FOR REVIEW AND IS FILED*** CERTIFICATE OF OCCUPANCY REQUIRED: NO CONST TYPE: 1-A OCCUPANCY: R-2 2006 IBC SPRINKLERED: YES SPRINKLER TYPE: NFPA 13 SOUND/FIRE TEST ASSEMBLY: ***PROVIDE MIN. STC AND IIC RATING OF 50 FOR SOUND MAT TO BE INSTALLED WHEN REPLACING FLOORING*** ENERGY CODE CHAPTER USED: NOT APPLICABLE ELEVATOR REVIEW; NOT APPLICABLE 20% ACCESSIBILITY UPGRADES: NO CHANGES TO EXISTING FLOOR LAYOUT TENANT: MR. JOE TENNYSON FLOOR(S): UNIT#1402 - 14TH FLOOR SAC: _N/A_CHARGES _N/A_CREDITS = _N/A_NET MET COUNCIL LETTER DATED: _N/A_ ARCHITECT: N/A ENGINEER: N/A windows with sill heights less than 24 inches above the floor shall be equipped with fall prevention devices that limit the window opening to less than 4 inches in accordance with MSBC 1303.2320 CARBON MONOXIDEStatus: finalType: CommercialEffective Date: 2014-11-26Permit Number: BLDG242840
October 23, 2012
Description: PLUM FIX Specify the type of fixtures by entering the quantity in the list below: Water Closets____ Urinals_____ Bath Tubs____ Basins____ Sinks_____ Wash Trays_____ Showers_____ Floor Drains____ Extensions_____ Misc Fixtures__1__ (Dishwasher) Electric Water Heaters_____ Other: Specify below Properly plug the unused plumbing openings at the nearest live main or branch on the waste and vent system. Cement is not an acceptable method of disconnect. Approved plumbing materials must be used. Dead ends are not permitted except where necessary to extend piping for a cleanout so as to be accessible. The work must be done by a licensed plumbing contractor in which a permit and inspection is required before concealing. Carbon monoxide detectors are required in dwelling units in accordance with Minnesota Statute 299F.50. Please refer to the following website for additional information. http://www.dli.mn.gov/CCLD/PDF/bc_websmoke_co_06_07.pdf Plans approved by both the State of Minnesota DepartmentStatus: finalType: PlumbingEffective Date: 2012-10-23Permit Number: BLDG499732
August 4, 2008
Description: MECH MECH | WARM AIR HEATING SYSTEMS | Scope of work: FOR #4102 - MODIFY DUCTWORK PER REMODELING MECH | Scope of work: FOR #4102 - MODIFY DUCTWORK PER REMODELING MECH | Scope of work: FOR #4102 - MODIFY DUCTWORK PER REMODELING MECH | Scope of work: FOR #4102 - MODIFY DUCTWORK PER REMODELINGStatus: finalType: MechanicalEffective Date: 2008-08-04Permit Number: BLDG302141
January 1, 1900
Description: Removal of old fan coil units and related duct work in each unit and replace with new fan coil duct work piping and controls from existing main risers. Condensate risers throughout the building were replaced as wellStatus: completeType: MechanicalBusiness Name: Egan Company INCApplicant: No Owner Information AvailableEffective Date: 1900-01-01Permit Number: BLDG750908

Current Ownership

Information about the current owner(s).

Property History

2950 Dean Pkwy 1402 has undefined property events records (listings, deeds, permits, tax, foreclosure, loan).

Property Events

Environment

Environmental factors around 2950 Dean Pkwy 1402

School Information

Public/private schools serving 2950 Dean Pkwy 1402

Neighborhood

This property is located in Cedar Isles Dean, Minneapolis, MN 55416.

Market Trends

Historical market data near 2950 Dean Pkwy 1402 over selected time period.

Nearby Properties on Dean Pkwy