  • Chat with Us
  • Submit Feedback
  • TopHap Academy
  • What's New?
Residential > Multi-family
Off-Market
Sold Price
$--$--/ft²

2811 N Bryant Ave
Minneapolis, MN 55411

2811 N Bryant Ave, Minneapolis, MN 55411 is a 3 bed, 2 bath, 1,363 ft² multi-family home house built in 1905 on a 0.120 acre lot with 15 construction permits. This multi-family home is currently off market. The latest TopHap estimate of the multi-family home's value is $233,000.

Property Valuations

Latest estimates for 2811 N Bryant Ave based on TopHap automated valuation model (AVM).

Permits

2811 N Bryant Ave has 15 permit records of total value of $142,000.

Permit History
15
Permits
$142,000
Total Permit Value
October 4, 2018
Project Name: House Rehab ElectricalDescription: Replace main electrical panel install new electric range circuit install new water heater circuits install smoke alarms ectStatus: finalType: Ele exst 1 or 2 familyBusiness Name: Current Electric SystemsApplicant: Blake WilliamsFees: $271Effective Date: 2018-10-04Permit Number: ELE1710-01084
November 28, 2017
Description: 12 fixturesStatus: completeType: plumbingBusiness Name: Blake WilliamsApplicant: Jacob J HallFees: $916Effective Date: 2017-11-28Permit Number: BLDG680904
November 28, 2017
Description: PLUM FIX 2 40,000 btu water heaters Specify the type of fixtures by entering the quantity in the list below: Water Closets__2__ Urinals_____ Bath Tubs__2__ Basins___2_ Sinks___2__ Wash Trays_____ Showers_____ Floor Drains____ Extensions_____ Misc Fixtures____ Electric Water Heaters_____ Other: Specify below Properly plug the unused plumbing openings at the nearest live main or branch on the waste and vent system. Cement is not an acceptable method of disconnect. Approved plumbing materials must be used. Dead ends are not permitted except where necessary to extend piping for a cleanout so as to be accessible. The work must be done by a licensed plumbing contractor in which a permit and inspection is required before concealing. Carbon monoxide detectors are required in dwelling units in accordance with Minnesota Statute 299F.50. Please refer to the following website for additional information. https://www.revisor.mn.gov/statutes/?id=299f.51 Plans approved by both the State of Minnesota DStatus: finalType: PlumbingApplicant: Jacob J HallEffective Date: 2017-11-28Permit Number: BLDG549800
November 7, 2017
Description: HVAC-LVL3 | Scope of work: INSTALL TWO FURNACES & DUCT SYSTEMS IN UPPER AND LOWER UNIT WITH BATH AND DRYER. HVAC WORK AND ENTIRE SYSTEM REPLACEMENT ** NO NEW CONSTRUCTION - Tear-downs and major remodels are considered new construction ** Identify number of each of the existing individual heating/cooling system being replaced, that serves an individual dwelling unit. Indicate the number of systems that apply: _2_Remove existing system and install new (boiler or forced air system) __Install a new system to serve an existing non-conditioned space REQUIRED FOR INSPECTION 1. HVAC equipment must be sized to ACCA manual J or an equivalent method. Heat loss calculations to be left next to appliances for inspection. Over-sizing of heating equipment must not exceed 43% and cooling equipment must not exceed 21%. 2. Documents relative to maintenance and startup testing (orsat) shall be affixed to the mechanical equipment. 3. All work done under this permit must be completed by a person with the prStatus: finalType: MechanicalApplicant: Jacob J HallEffective Date: 2017-11-07Permit Number: BLDG365388
June 19, 2017
Description: Full remodelStatus: finalType: Electrical permitSub Type: One and two family dwellingFees: $145Effective Date: 2017-06-19Permit Number: ELE1605-07006
April 18, 2017
Description: Temporary Natural Gas Heater Temporary Natural Gas HeaterStatus: finalType: MechanicalApplicant: Jacob J HallFees: $81Effective Date: 2017-04-18Permit Number: BLDG627702
July 20, 2016
Description: DumpsterStatus: OpenType: Street use permitSub Type: BsuBusiness Name: Boone ContainerApplicant: Blake WilliamsFees: $81Effective Date: 2016-07-20Permit Number: 1049965
May 26, 2016
Description: 2 40, 000 btu water heatersStatus: OpenType: plumbingSub Type: BtpaBusiness Name: Lake City MechanicalApplicant: Blake WilliamsFees: $512Effective Date: 2016-05-26Permit Number: 5194210
May 24, 2016
Description: Install two furnaces & duct systems in upper and lower unit with bathroom and dryerStatus: OpenType: HVAC alterationsSub Type: BtmbBusiness Name: Lacy MechanicalApplicant: Blake WilliamsFees: $209Effective Date: 2016-05-24Permit Number: 4118149
March 14, 2016
Description: Code compliance repairs to duplexJob Value: $60,000Status: OpenType: RemodelingSub Type: BireBusiness Name: Wenrich Property & Development LlcApplicant: Blake WilliamsFees: $1,148Effective Date: 2016-03-14Permit Number: 3103365
May 27, 2015
Description: Street use permit is valid for _30___ days from date of issuanceStatus: DoneType: Street use permitSub Type: BsuBusiness Name: Boone ContainerApplicant: Hennepin Forfeited LandFees: $81Effective Date: 2015-05-27Permit Number: 1044954
June 12, 2008
Description: Dumpster 30 days starting 6/12/08Status: DoneType: Street use permitSub Type: BsuBusiness Name: Aspen Waste Systems IncApplicant: Hennepin Forfeited LandFees: $66Effective Date: 2008-06-12Permit Number: 1023209
June 7, 1985
Description: Plan inspection fee per glenn thompsonStatus: DoneType: BuildingSub Type: BApplicant: Hennepin Forfeited Land0Effective Date: 1985-06-07Permit Number: 536866
June 7, 1985
Description: Convert sgle dwlg to dx all wk to meetxxJob Value: $22,000Status: DoneType: BuildingSub Type: BApplicant: Hennepin Forfeited Land0Effective Date: 1985-06-07Permit Number: 536851
January 1, 1900
Description: *irc2-r/r code compliance repairs to duplex. Including new exterior stair to 2nd floor unit. Engineer's report provided. ****** exterior stair design change approved 11/16/16 sound/fire test assembly___floor: ga fc5120___ no internal stair - no common walls___ separate permits are required for electrical plumbing and heating/air conditioning/ventilation work. This work must be completed by a licensed contractor in a multi-family dwelling. Carbon monoxide alarms required in accordance with mn. Stat. 299f.50 irc 313.2.1. When interior alterations repairs or additions require a building permit or when one or more sleeping rooms are added or created in existing dwellings smoke detection shall be installed: a. On each level of the house b. In each bedroom c. In the hall or room outside of bedrooms. Exceptions: 1. Smoke alarms in existing areas shall not be required to be interconnected and hardwired where the alterations or repairs do not result in the removal of interior wall or ceiling fiJob Value: $60,000Status: completeType: ResidentialBusiness Name: Wenrich Property & DEV LLCApplicant: Tiana TownsEffective Date: 1900-01-01Permit Number: BLDG61699

Current Ownership

Information about the current owner(s).

Property History

2811 N Bryant Ave has undefined property events records (listings, deeds, permits, tax, foreclosure, loan).

Property Events

Environment

Environmental factors around 2811 N Bryant Ave

School Information

Public/private schools serving 2811 N Bryant Ave

Neighborhood

This property is located in Hawthorne, Minneapolis, MN 55411.

Market Trends

Historical market data near 2811 N Bryant Ave over selected time period.

Nearby Properties on Bryant Ave