  • Chat with Us
  • Submit Feedback
  • TopHap Academy
  • What's New?
Residential > House
Sold
12/28/2016
Sold Price
$--$--/ft²

2723 Dean Pkwy
Minneapolis, MN 55416

2723 Dean Pkwy, Minneapolis, MN 55416 is a 5 bed, 4 bath, 3,033 ft² house built in 1927 on a 0.150 acre lot with 30 construction permits. This house is currently off market, and it was last sold in 2016. The latest TopHap estimate of the house's value is $1,369,713.

Property Valuations

Latest estimates for 2723 Dean Pkwy based on TopHap automated valuation model (AVM).

Permits

2723 Dean Pkwy has 30 permit records of total value of $139,980.

Permit History
30
Permits
$139,980
Total Permit Value
September 4, 2019
Description: BoilerStatus: completeType: MechanicalBusiness Name: Uptown Plumbing Heating & CoolingApplicant: Brian T SchubringFees: $128Effective Date: 2019-09-04Permit Number: BLDG692277
January 18, 2013
Description: *IRC1-R/R REMODEL TO SFD. RELOCATE NEW BASMENT 20 MIN DOOR OPENING BETWEEN ATTACHED (DMH#2) GARAGE AND BASEMENT SPACE. INSTALL NEW 4.5' AND 4' STEEL BEAMS POSTED OVER EXISTING FOUNDATION FOR ATTACHED GARAGE STORAGE SPACE AND FRAME NEW ADJACENT FIRE WALL. BASEMENT PARTITION WALL FOR MECHANICAL ROOM. AT MAIN FLOOR, GUT & REMODEL KITCHEN. DEMO STAIRS AND INFILL OPENING. NEW 1/2 BATH ADJACENT TO KITCHEN. CHANGE 3 SEASON INTO HEATED SPACE WITH NEW BOW WINDOW AND FRENCH DOOR AND FINISH EXTERIOR WITH STUCCO FINISH TO EXISTING WALK-OUT OVER ATT. GARAGE. AT 2ND FLOOR, MODIFY EXISTING BEDROOM WITH NEW PARITION WALL FOR WALK-IN CLOSET AND 3/4 BATHROOM. MODIFY EXISTING CLOSET FOR NEW LAUNDRY ROOM. CEMENT, FIBER-CEMENT OR GLASS MAT GYPSUM BACKERS SHALL BE USED AS BACKERS FOR WALL TILE IN BATHTUB/SHOWER LOCATIONS AND INSTALLED PER MANUFACTURER RECOMMENDATIONS. 2007 MNSBC- IRC 702.4.2 SMOKE DETECTORS AND CARBON MONOXIDE DETECTORS SHALL BE INSTALLED AND OPERABLE AT THE TIME THE BUILDING INSPECTOR PERFStatus: finalType: ResidentialApplicant: Brian T SchubringEffective Date: 2013-01-18Permit Number: BLDG77158
December 21, 2012
Description: PLUMB MOVE METER FROM INSIDE BUILDING TO OUTSIDE BUILDING Properly plug the unused plumbing openings at the nearest live main or branch on the waste and vent system. Cement is not an acceptable method of disconnect. Approved plumbing materials must be used. Dead ends are not permitted except where necessary to extend piping for a cleanout so as to be accessible. The work must be done by a licensed plumbing contractor in which a permit and inspection is required before concealing. Carbon monoxide detectors are required in dwelling units in accordance with Minnesota Statute 299F.50. Please refer to the following website for additional information. http://www.dli.mn.gov/CCLD/PDF/bc_websmoke_co_06_07.pdf Plans approved by both the State of Minnesota Department of Health and the Department of Labor and Industry are required to be on site for all plumbing work conducted in hospitals, nursing homes, supervised living facilities, outpatient surgical centers, boarding care homes, and residentiaStatus: finalType: PlumbingBusiness Name: Centerpoint EnergyApplicant: Brian T SchubringEffective Date: 2012-12-21Permit Number: BLDG595551
December 18, 2012
Description: Install new 200 amp sevice panel meter mast. Install 12 new circuits in open walls all over houseStatus: finalType: Ele exst 1 or 2 familySub Type: Residential exstBusiness Name: Affordable ElectricApplicant: Jon OrfieldFees: $282Effective Date: 2012-12-18Permit Number: ELE1204-02348
December 17, 2012
Description: Move meter from inside building to outside buildingStatus: DoneType: plumbingSub Type: BtpaBusiness Name: Centerpoint Energy Minnesota GasApplicant: Linda Shubring Et AlFees: $81Effective Date: 2012-12-17Permit Number: 5147378
December 17, 2012
Description: PLUM FIX Specify the type of fixtures by entering the quantity in the list below: Water Closets____ Urinals_____ Bath Tubs____ Basins____ Sinks_____ Wash Trays_____ Showers_____ Floor Drains____ Extensions_____ Misc Fixtures__water maker__ Electric Water Heaters_____ Other: Specify below Properly plug the unused plumbing openings at the nearest live main or branch on the waste and vent system. Cement is not an acceptable method of disconnect. Approved plumbing materials must be used. Dead ends are not permitted except where necessary to extend piping for a cleanout so as to be accessible. The work must be done by a licensed plumbing contractor in which a permit and inspection is required before concealing. Carbon monoxide detectors are required in dwelling units in accordance with Minnesota Statute 299F.50. Please refer to the following website for additional information. http://www.dli.mn.gov/CCLD/PDF/bc_websmoke_co_06_07.pdf Plans approved by both the State of Minnesota Department ofStatus: finalType: PlumbingBusiness Name: Foremost Mechanical CorpApplicant: Brian T Schubring0Effective Date: 2012-12-17Permit Number: BLDG486821
December 17, 2012
Description: PLUM FIX Specify the type of fixtures by entering the quantity in the list below: Water Closets__2__ Urinals_____ Bath Tubs___1_ Basins__2__ Sinks___1__ Wash Trays_____ Showers____1_ Floor Drains___1_ Extensions_____ Misc Fixtures___3_ Electric Water Heaters_____ Other: Specify below dw, stand pipe, DP gas range, 90 ' water piping Properly plug the unused plumbing openings at the nearest live main or branch on the waste and vent system. Cement is not an acceptable method of disconnect. Approved plumbing materials must be used. Dead ends are not permitted except where necessary to extend piping for a cleanout so as to be accessible. The work must be done by a licensed plumbing contractor in which a permit and inspection is required before concealing. Carbon monoxide detectors are required in dwelling units in accordance with Minnesota Statute 299F.50. Please refer to the following website for additional information. http://www.dli.mn.gov/CCLD/PDF/bc_websmoke_co_06_07.pdf Plans approved Status: finalType: PlumbingBusiness Name: Peterson Plbg & Htg IncApplicant: Brian T SchubringEffective Date: 2012-12-17Permit Number: BLDG495497
November 30, 2012
Description: MECH MECH | Scope of work: INSTALL CARRIER 2 TON A/C MODEL ON NORTH SIDE OF HOUSE Heating load calculation forms for furnaces and boilers installed in single family homes or duplexes are required to be left at the job site along with the homeowner package of information that includes the design, testing, and installation instructions. Contractors should be using manual J residential load calculations hand written or software designed. Carbon monoxide detectors are required in dwelling units in accordance with Minnesota Statute 299F.50. Please refer to the following website for additional information. http://www.dli.mn.gov/CCLD/PDF/bc_websmoke_co_06_07.pdf HVAC equipment is allowed as a permitted obstruction in a required side or rear yard as follows: Air-conditioning systems, heating, ventilating, and filtering equipment, not to exceed four (4) feet in height and adjacent to a nonresidential use or adjacent to a residential use which is equipped with central air conditioning or which hStatus: finalType: MechanicalApplicant: Brian T SchubringEffective Date: 2012-11-30Permit Number: BLDG344268
November 28, 2012
Description: MECH MECH | Scope of work: BOILER Heating load calculation forms for furnaces and boilers installed in single family homes or duplexes are required to be left at the job site along with the homeowner package of information that includes the design, testing, and installation instructions. Contractors should be using manual J residential load calculations hand written or software designed. Carbon monoxide detectors are required in dwelling units in accordance with Minnesota Statute 299F.50. Please refer to the following website for additional information. http://www.dli.mn.gov/CCLD/PDF/bc_websmoke_co_06_07.pdf HVAC equipment is allowed as a permitted obstruction in a required side or rear yard as follows: Air-conditioning systems, heating, ventilating, and filtering equipment, not to exceed four (4) feet in height and adjacent to a nonresidential use or adjacent to a residential use which is equipped with central air conditioning or which has no windows or doors in the wall immediately aStatus: finalType: MechanicalApplicant: Brian T SchubringEffective Date: 2012-11-28Permit Number: BLDG331884
July 27, 2012
Description: Install vacuum breaker for lawn irrigationStatus: DoneType: plumbingSub Type: BtpaBusiness Name: Rm MechanicalApplicant: Linda Shubring Et AlFees: $81Effective Date: 2012-07-27Permit Number: 5141873
May 30, 2012
Description: Specify the type of fixtures by entering the quantity in the list below:Status: DoneType: plumbingSub Type: BtpaBusiness Name: Foremost Mechanical CorpApplicant: Linda Shubring Et AlFees: $81Effective Date: 2012-05-30Permit Number: 5139521
May 30, 2012
Description: Install carrier 2 ton air conditioning model on north side of houseStatus: DoneType: MechanicalSub Type: BtmaBusiness Name: Acclaim Services, IncApplicant: Linda Shubring Et AlFees: $78Effective Date: 2012-05-30Permit Number: 4105964
May 30, 2012
Description: BoilerStatus: DoneType: MechanicalSub Type: BtmaBusiness Name: Foremost Mechanical CorpApplicant: Linda Shubring Et AlFees: $143Effective Date: 2012-05-30Permit Number: 4105967
May 24, 2012
Description: REROOF TEAROFF AND REROOF HOUSE All exterior work to be completed within one year of permit issuance date per Minneapolis City Ordinance 89.165 All roof drains, area drains, or other stormwater or clearwater connections to the City's sanitary sewer system must be disconnected per Chapter 56 of the Minneapolis Code of Ordinances. Contact Arvella Greenway at 612 673 5899 if you questions. Carbon monoxide detectors are required in dwelling units in accordance with Minnesota Statute 299F.50. Please refer to the following website for additional information. http://www.doli.state.mn.us/pdf/bcs_co_detectors_joint_memo_july06.pdfStatus: finalType: ResidentialApplicant: Brian T SchubringEffective Date: 2012-05-24Permit Number: BLDG139510
May 16, 2012
Description: Attic air conditioning installation handler and ductwork in attic install 1 bathroom fan on main level. 2 bathroom fans on second floorStatus: DoneType: MechanicalSub Type: BtmaBusiness Name: Hi-tech RefrigerationApplicant: Linda Shubring Et AlFees: $124Effective Date: 2012-05-16Permit Number: 4105702
May 14, 2012
Description: Specify the type of fixtures by entering the quantity in the list below:Status: DoneType: plumbingSub Type: BtpaBusiness Name: Peterson Plbg & Htg, IncApplicant: Linda Shubring Et AlFees: $521Effective Date: 2012-05-14Permit Number: 5138974
April 17, 2012
Description: KIVA Permit Type: FDDP KIVA Permit number: 156479 KIVA Permit Name: ABANDON 1 TANK -- -- --Status: finalType: TankApplicant: Brian T SchubringEffective Date: 2012-04-17Permit Number: BLDG643043
April 17, 2012
Status: DoneType: Fire department daily permitsSub Type: FddpBusiness Name: Deans Tank IncApplicant: Linda Shubring Et AlFees: $69Effective Date: 2012-04-17Permit Number: 156479
April 16, 2012
Description: This permit is for the abandonment in place of one 1000 gallon out of service undergroudn fuel oil tankStatus: DoneType: Env. Tank permitSub Type: BetpBusiness Name: Deans Tank IncApplicant: Linda Shubring Et AlFees: $368Effective Date: 2012-04-16Permit Number: 1000917
January 23, 2012
Description: Remodel to single family dwelling. Relocate new basment 20 min door opening between attached (dmh#2)Job Value: $126,000Status: DoneType: RemodelingSub Type: BireBusiness Name: Orfield Construction LlcApplicant: Linda Shubring Et AlFees: $2,527Effective Date: 2012-01-23Permit Number: 3076336
October 19, 2011
Description: Tearoff and reroof houseStatus: DoneType: Building over the counterSub Type: BotcBusiness Name: Orfield Construction LlcApplicant: Linda Shubring Et AlFees: $168Effective Date: 2011-10-19Permit Number: 1099400
November 20, 2006
Description: Water htr replace existing water heater - is this a gas water heater(y/n)?__y_ - is this an electric water heater(y/n)?__ note: an electric water heater replacement also requires an electrical permit - other: describe belowStatus: finalType: plumbingApplicant: Brian T SchubringEffective Date: 2006-11-20Permit Number: BLDG452401
October 23, 2006
Description: Replace existing water heaterStatus: DoneType: plumbingSub Type: BtpaBusiness Name: Norblom PlumbingApplicant: Linda Shubring Et AlFees: $62Effective Date: 2006-10-23Permit Number: 5080839
October 4, 2004
Description: City elevator # 11611 new install (djh) chair 2 residential install battery operated stair chair capacity: 319 lb speed: 24 ft/min owner: 2723 dean parkway florence schoff 612-377-2400Job Value: $3,495Status: InactiveType: Elevator permitSub Type: ElevatorBusiness Name: Arrow Lift AccessibilityApplicant: Brian Schubring0Effective Date: 2004-10-04Permit Number: LIC93496
October 4, 2004
Description: City elevator # 11611 new install (djh) chair 2 residentialJob Value: $3,495Status: DoneType: ElevatorSub Type: BtelBusiness Name: Arrowlift AccessibilityApplicant: Linda Shubring Et AlFees: $57Effective Date: 2004-10-04Permit Number: 1003950
October 4, 2004
Description: City elevator - 11610 new install (djh) chair 1 residentialJob Value: $3,495Status: DoneType: ElevatorSub Type: BtelBusiness Name: Arrowlift AccessibilityApplicant: Linda Shubring Et AlFees: $57Effective Date: 2004-10-04Permit Number: 1003949
January 1, 1900
Description: City elevator - 11610 new install (djh) chair 1 residential install battery operated stairchair. Capacity: 319 lb speed: 24 ft/min owner: 2723 dean parkway florence schoff 612-377-2400Job Value: $3,495Status: expiredType: ElevatorBusiness Name: Arrow Lift AccessibilityApplicant: Brian T SchubringEffective Date: 1900-01-01Permit Number: LIC101331
January 1, 1900
Description: Kiva permit type: betp kiva permit number: 1000917 kiva permit name: ust aip-resd -- rfs number: 12-0912323 -- envmgmt -- this permit is for the abandonment in place of one 1000 gallon out of service undergroudn fuel oil tank. Work is scheduled for 4/17/2012. This permit is for the abandonment in place of one 1, 000 gallon underground storage tank used for fuel oil. Work is scheduled to begin 3/21/2012. If rescheduled text tom frame at 612-685-8501 of leave an email at tom.frame@minneapolismn.gov with cancellation and new work date. No construction demolition or commercial power maintenance equipment shall be operated within the city between the hours of 6:00 P.M. And 7:00 A.M. On weekdays or during any hours on saturdays sundays and state and federal holidays except under permit. Contact environmental services at 612-673-3867 for permit information. Issuance of this environmental services permit does not eliminate the need for additional permits required by this code or other governmeStatus: completeType: TankBusiness Name: Deans TankApplicant: Brian T SchubringEffective Date: 1900-01-01Permit Number: BLDG640474
January 1, 1900
Description: plumbing install vacuum breaker for lawn irrigationStatus: completeType: plumbingBusiness Name: RM Mechanical INCApplicant: Brian T SchubringEffective Date: 1900-01-01Permit Number: BLDG517406
January 1, 1900
Description: Mechanical mechanical | warm air heating systems | scope of work: attic air conditioning installation handler and ductwork in attic install 1 bathroom fan on main level. 2 bathroom fans on second floor heating load calculation forms for furnaces and boilers installed in single family homes or duplexes are required to be left at the job site along with the homeowner package of information that includes the design testing and installation instructions. Contractors should be using manual j residential load calculations hand written or software designed. Carbon monoxide detectors are required in dwelling units in accordance with minnesota statute 299f.50. Please refer to the following website for additional information. Http://www.dli.mn.gov/ccld/pdf/bc_websmoke_co_06_07.pdf HVAC equipment is allowed as a permitted obstruction in a required side or rear yard as follows: air-conditioning systems heating ventilating and filtering equipment not to exceed four (4) feet in height and adjacent tStatus: completeType: MechanicalBusiness Name: HI Tech Refrigeration INCApplicant: Brian T SchubringEffective Date: 1900-01-01Permit Number: BLDG396894

Current Ownership

Information about the current owner(s).

Property History

2723 Dean Pkwy has undefined property events records (listings, deeds, permits, tax, foreclosure, loan).

Property Events

Environment

Environmental factors around 2723 Dean Pkwy

School Information

Public/private schools serving 2723 Dean Pkwy

Neighborhood

This property is located in Walton Hills, Minneapolis, MN 55416.

Market Trends

Historical market data near 2723 Dean Pkwy over selected time period.

Nearby Properties on Dean Pkwy