  • Chat with Us
  • Submit Feedback
  • TopHap Academy
  • What's New?
Residential > House
Sold
03/25/2021
Sold Price
$1,050,000$418/ft²

2415 22nd St
Minneapolis, MN 55405

2415 22nd St, Minneapolis, MN 55405 is a 3 bed, 4 bath, 2,513 ft² house built in 1923 on a 0.190 acre lot with 42 construction permits. This house is currently off market, and it was last sold in 2021 for $1,050,000. The latest TopHap estimate of the house's value is $1,204,279.

Property Valuations

Latest estimates for 2415 22nd St based on TopHap automated valuation model (AVM).

Permits

2415 22nd St has 42 permit records of total value of $835,695.

Permit History
42
Permits
$835,695
Total Permit Value
November 15, 2021
Description: Porch remodelStatus: issuedType: Electrical permitSub Type: One-family dwellingApplicant: Hanson Remodeling PorchFees: $71Effective Date: 2021-11-15Permit Number: ELE2111-06395
May 27, 2021
Description: Electrical to radon systemStatus: finalType: Electrical permitSub Type: One-family dwellingApplicant: Pete SkriefFees: $36Effective Date: 2021-05-27Permit Number: ELE2105-02210
January 18, 2017
Status: finalType: PlumbingBusiness Name: Fireside Hearth & HomeApplicant: Linda C BreitagEffective Date: 2017-01-18Permit Number: BLDG552043
January 18, 2017
Status: finalType: PlumbingBusiness Name: Practical SystemsApplicant: Linda C Breitag0Effective Date: 2017-01-18Permit Number: BLDG547833
January 18, 2017
Description: Total of (2) fixtures total of (2) fixturesStatus: finalType: plumbingBusiness Name: Johnson Plumbing & Heating CoApplicant: Linda C BreitagFees: $82Effective Date: 2017-01-18Permit Number: BLDG624957
January 18, 2017
Status: finalType: PlumbingBusiness Name: Johnson Plumbing & HeatingApplicant: Linda C BreitagEffective Date: 2017-01-18Permit Number: BLDG585447
January 13, 2017
Project Name: 51165Description: Ll work----add wiring for 2 wall sconces in theatre room with 1 switch addition wiring for new wet bar rewire relocated geothermal and rewire boiler wire new indirect water heater pump relocate the 200amp main panel over to the same wall as the 100amp panel new hallway to bedrooms (add 2 ceiling lights and 2 switches addition 2 outlets addition 1 combo smoke/co) guest room 1 and 2 (add 1 ceiling light and 1 switch addition outlets to code addition 1 smoke) wire lower level bathroomStatus: finalType: Ele exst 1 or 2 familyBusiness Name: Electric City CorporationApplicant: Miller ResidenceFees: $106Effective Date: 2017-01-13Permit Number: ELE1609-02817
November 8, 2016
Description: | Scope of work: DISCONNECT GEO SYSTEM, REPIPE PRIMARY LOOP AND REUSE EXISTING PRIMARY PUMP, REOUTE MASTER BEDROOM INFLOOR HEATING, REROUTE BASEMENT INFLOOR HEATING, REPIPE KITCHEN ZONE AND RETURN PIPES BACK TO BOILER, VENT BOILER, CONDENSATION PUMP AND RUN DRAIN LINE, REPIPE COOLING PIPES BACK TO NEW MECHANICAL ROOM, REPLACE BOILER WITH NTI TFT 95% ,MODULATING BOILER, BUFFER TANK, CONVERT COOLING SYSTEM, INSTALL HEAT EXCHANGER, PUMP AND EXPANSION TANKS. INSTALL INFLOOR HEAT IN GYM, BATH AND BEDROOM2, INSTALL AND VENT PANASONIC 80 CFM BATH FAN, REPLACE RADIATOR IN MASTER BEDROOM, 8' SECTION OF CAST IRON BASEBOARD IN MASTER BEDROOM, CONDENSATION PUMP FOR WINE ROOM COOLER AND DRAIN LINE, 8' CAST IRON BASEBOARD IN MAIN FLOOR OFFICE _______________________________________ HVAC WORK AND ENTIRE SYSTEM REPLACEMENT ** NO NEW CONSTRUCTION - Tear-downs and major remodels are considered new construction ** Identify number of each of the existing individual heating/cooling system being replaced, tStatus: finalType: MechanicalBusiness Name: Practical SystemsApplicant: Linda C Breitag0Effective Date: 2016-11-08Permit Number: BLDG366824
November 4, 2016
Description: Install gas insert and gas lineStatus: OpenType: plumbingSub Type: BtpaBusiness Name: Fireside Hearth & HomeApplicant: Jay D MillerFees: $82Effective Date: 2016-11-04Permit Number: 5199208
September 20, 2016
Description: Street use permit is valid for __30__ days from date of issuanceStatus: OpenType: Street use permitSub Type: BsuBusiness Name: Mac's Roll-off ServiceApplicant: Jay D MillerFees: $81Effective Date: 2016-09-20Permit Number: 1050645
August 18, 2016
Description: Install new basement bathroom toilet shower and lav sink addition new bar sink and relocate indirect water heaterStatus: OpenType: plumbingSub Type: BtpaBusiness Name: Johnson Plumbing & HeatingApplicant: Jay D MillerFees: $200Effective Date: 2016-08-18Permit Number: 5196680
July 18, 2016
Description: Street use permit is valid for _30___ days from date of issuanceStatus: OpenType: Street use permitSub Type: BsuBusiness Name: Mac's Roll-off ServiceApplicant: Jay D MillerFees: $81Effective Date: 2016-07-18Permit Number: 1049934
July 12, 2016
Description: Basement remodel. Sck#2Job Value: $75,570Status: OpenType: RemodelingSub Type: BireBusiness Name: Building Arts Sustainable Architecture & Construction LlcApplicant: Jay D MillerFees: $1,623Effective Date: 2016-07-12Permit Number: 3105903
July 12, 2016
Description: *IRC1-R/R basement remodel. sck#2 minor finish work on other floors does not require permit SEPARATE PERMITS ARE REQUIRED FOR ELECTRICAL, PLUMBING, AND HEATING/AIR CONDITIONING/VENTILATION WORK. CARBON MONOXIDE ALARMS REQUIRED IN ACCORDANCE WITH MN. STAT. 299F.50 IRC 313.2.1. When interior alterations, repairs or additions require a building permit or when one or more sleeping rooms are added or created in existing dwellings, smoke detection shall be installed: A. on each level of the house B. in each bedroom C. in the hall or room outside of bedrooms. Exceptions: 1. Smoke alarms in existing areas shall not be required to be interconnected and hardwired where the alterations or repairs do not result in the removal of interior wall or ceiling finishes exposing the structure, unless there is a crawl space or basement available which could provide access for hardwiring and interconnection without the removal of interior finishes. 2. Work on the exterior which does not require entry into tJob Value: $75,570Status: filedType: Residential; Residential Building PermitSub Type: ResBusiness Name: Bldg Arts Sustainable Architecture & Constructio; BLDG ARTS SUSTAINABLE ARCHITECTURE AND CONSTRUCTIOApplicant: Linda C Breitag; JAY D MILLERFees: $1,623Effective Date: 2016-07-12Permit Number: BLDG63472
July 7, 2016
Description: Disconnect geo system repipe primary loop and reuse existing primary pump reoute master bedroom infloor heating reroute basement infloor heating repipe kitchen zone and return pipes back to boiler vent boiler condensation pump and run drain line repipe cooling pipes back to new mechanical room replace boiler with nti tft 95% , modulating boiler buffer tank convert cooling system install heat exchanger pump and expansion tanks. Install infloor heat in gym bathroom and bedroom2 install and vent panasonic 80 cfm bathroom fan replace radiator in master bedroom 8 section of cast iron baseboard in master bedroom condensation pump for wine room cooler and drain line 8 cast iron baseboard in main floor officeStatus: OpenType: HVAC alterationsSub Type: BtmbBusiness Name: Practical SystemsApplicant: Jay D MillerFees: $209Effective Date: 2016-07-07Permit Number: 4118843
July 7, 2016
Description: Gas line from new meter to new mechanical roomStatus: OpenType: plumbingSub Type: BtpaBusiness Name: Practical SystemsApplicant: Jay D MillerFees: $82Effective Date: 2016-07-07Permit Number: 5195406
July 26, 2013
Project Name: CDescription: Air handler water htrStatus: finalType: Ele exst 1 or 2 familySub Type: Residential exstBusiness Name: Powerhouse Electric INCApplicant: Jay MillerFees: $40Effective Date: 2013-07-26Permit Number: ELE1301-01435
January 28, 2013
Description: HVAC W/BNR | Scope of work: HVAC W/BNR - HVAC ALTERATIONS FOR INDIVIDUAL DWELLING UNIT (If multi-unit building, identify the dwelling unit: ____) REPLACE BOILER This permit authorizes the following identified mechanical work to replace and/or modify the existing individual heating/cooling system that serves an individual dwelling unit. Check all that apply. _X_ Replace boiler including piping alterations __ Replace furnace including duct alterations __ Add or replace heater for space heating __ Add or replace air conditioner with furnace including duct alterations**. ITEMS REQUIRED FOR INSPECTION 1. HVAC equipment must be sized according to ACCA manual J or an equivalent method. Calculations to be left next to the new appliances for inspection. Over sizing of heating equipment must not exceed 43% and cooling equipment must not exceed 21%. 2. All documentation relative to maintenance and startup testing (orsat) shall be affixed to the mechanical equipment. 3. All work done under this peStatus: finalType: MechanicalBusiness Name: Centraire Heating & Air Conditioning IncApplicant: Linda C BreitagEffective Date: 2013-01-28Permit Number: BLDG344956
January 28, 2013
Description: PLUMB ON DEMAND WATER HEATER Properly plug the unused plumbing openings at the nearest live main or branch on the waste and vent system. Cement is not an acceptable method of disconnect. Approved plumbing materials must be used. Dead ends are not permitted except where necessary to extend piping for a cleanout so as to be accessible. The work must be done by a licensed plumbing contractor in which a permit and inspection is required before concealing. Carbon monoxide detectors are required in dwelling units in accordance with Minnesota Statute 299F.50. Please refer to the following website for additional information. http://www.dli.mn.gov/CCLD/PDF/bc_websmoke_co_06_07.pdf Plans approved by both the State of Minnesota Department of Health and the Department of Labor and Industry are required to be on site for all plumbing work conducted in hospitals, nursing homes, supervised living facilities, outpatient surgical centers, boarding care homes, and residential hospice facilities.Status: finalType: PlumbingBusiness Name: Centraire Heating & Air Conditioning IncApplicant: Linda C BreitagEffective Date: 2013-01-28Permit Number: BLDG500703
December 27, 2012
Description: On demand water heaterStatus: DoneType: plumbingSub Type: BtpaBusiness Name: Centraire Heating & Air ConditioningApplicant: Jay D MillerFees: $81Effective Date: 2012-12-27Permit Number: 5148588
December 27, 2012
Description: HVAC w/bnr - HVAC alterations for individual dwelling unitStatus: DoneType: HVAC alterationsSub Type: BtmbBusiness Name: Centraire Heating & Air ConditioningApplicant: Jay D MillerFees: $125Effective Date: 2012-12-27Permit Number: 4101580
November 13, 2009
Status: finalType: PlumbingBusiness Name: Blaylock Plumbing Co IncApplicant: Linda C BreitagEffective Date: 2009-11-13Permit Number: BLDG490072
November 12, 2009
Description: R3/ADDN CONSTRUCT TWO STORY REAR ADDITION WITH BASEMENT AND CRAWL SPACE TO EXISTING SFD. AAJ#1. - REMODEL EXISTING BASEMENT FLOOR, MAIN FLOOR AND 2ND FLOOR TO ALLOW FOR NEW REAR ADDITION. - INSTALL NEW REINFORCED FOUNDATION WALLS WITH FOOTINGS TO ENCLOSE NEW BASEMENT FAMILY ROOM ADDITION AND CRAWL SPACE WITH ACCESS TO EXISTING BASEMENT FLOOR. - INSTALL NEW KITCHEN EXPANSION, SUNROOM EXPANSION, MUD ROOM, HALF BATHROOM AND OPEN PORCH WITH ROOF DECK ADDITION TO EXISTING MAIN FLOOR. - INSTALL NEW BEDROOM #2, YOGA ROOM, BATHROOM, CLOSETS AND ROOF DECK ADDITION TO EXISTING 2ND FLOOR. - REBUILD EXISTING MASTER BATHROOM AND INSTALL NEW FIXTURES TO CODE REQUIREMENT. - INSULATE WALLS, ROOF DECK AND ROOF CEILING TO COD EREQUIREMENT. - REPAIR EXISTING FRONT CONCRETE STOOP AND STEPS. - INSTALL NEW METAL ROOF PER MANUFACTURER'S SPECIFICATIONS ON FRONT OPEN PORCH AND ENTIRE HOUSE. - UPDATE ALL MECHANICAL, ELECTRICAL, PLUMBING AND HEATING WORK TO CODE REQUIREMENT. CALL 651-454-0002, 48 HOURS BEFORE DIJob Value: $295,000Status: finalType: ResidentialBusiness Name: Otogawa Anschel Design BuildApplicant: Linda C Breitag0Effective Date: 2009-11-12Permit Number: BLDG26456
November 2, 2009
Description: PLUM FIX Specify the type of fixtures by entering the quantity in the list below: Water Closets_3___ Urinals_____ Bath Tubs_1___ Basins__2__ Sinks__1___ Wash Trays___1__ Showers_____ Floor Drains____ Extensions_____ Misc Fixtures____ Electric Water Heaters_____ Other: Specify below INSTALL (1) GAS RANGE @ 35,000 BTU Owner's Name _________________ Phone# ______________Status: finalType: PlumbingBusiness Name: Blaylock Plumbing Co IncApplicant: Linda C BreitagEffective Date: 2009-11-02Permit Number: BLDG448060
October 15, 2009
Description: Specify the type of fixtures by entering the quantity in the list below:Status: DoneType: plumbingSub Type: BtpaBusiness Name: Blaylock Plumbing CoApplicant: Jay D MillerFees: $164Effective Date: 2009-10-15Permit Number: 5110246
April 17, 2009
Description: MECH MECH | Scope of work: INSTALL GEOTHERMAL HEAT FOR HEATING AND COOLING. PIPE CHILLED WATER COIL INTO BOILER PIPING SYSTEM. MECH | Scope of work: INSTALL GEOTHERMAL HEAT FOR HEATING AND COOLING. PIPE CHILLED WATER COIL INTO BOILER PIPING SYSTEM. MECH | Scope of work: INSTALL GEOTHERMAL HEAT FOR HEATING AND COOLING. PIPE CHILLED WATER COIL INTO BOILER PIPING SYSTEM. MECH | Scope of work: INSTALL GEOTHERMAL HEAT FOR HEATING AND COOLING. PIPE CHILLED WATER COIL INTO BOILER PIPING SYSTEM.Status: finalType: MechanicalBusiness Name: Centraire Htg & A / C IncApplicant: Linda C BreitagEffective Date: 2009-04-17Permit Number: BLDG305058
April 17, 2009
Description: MECH MECH | WARM AIR HEATING SYSTEMS | Scope of work: CARRIER A/C 3.5 TON FOR ATTIC VENT BATH FANS AND KITCHEN HOOD EXTEND HOT WATER HEAT INTO ADDITION MECH | Scope of work: CARRIER A/C 3.5 TON FOR ATTIC VENT BATH FANS AND KITCHEN HOOD EXTEND HOT WATER HEAT INTO ADDITION MECH | Scope of work: CARRIER A/C 3.5 TON FOR ATTIC VENT BATH FANS AND KITCHEN HOOD EXTEND HOT WATER HEAT INTO ADDITION MECH | Scope of work: CARRIER A/C 3.5 TON FOR ATTIC VENT BATH FANS AND KITCHEN HOOD EXTEND HOT WATER HEAT INTO ADDITIONStatus: finalType: MechanicalBusiness Name: Centraire Htg & Air Cond IncApplicant: Linda C BreitagEffective Date: 2009-04-17Permit Number: BLDG295604
May 13, 2008
Description: Install geothermal heat for heating and cooling. Pipe chilled water coil into boiler piping systemStatus: DoneType: MechanicalSub Type: BtmaBusiness Name: Centraire Htg & A/c, IncApplicant: Jay D MillerFees: $132Effective Date: 2008-05-13Permit Number: 4075693
May 8, 2008
Description: 1 drill rig grouter trailer support truckStatus: DoneType: Env. After hours work permitSub Type: BeahBusiness Name: Bergerson Caswell, IncApplicant: Jay D MillerFees: $127Effective Date: 2008-05-08Permit Number: 1001796
January 15, 2008
Description: Carrier air conditioning 3.5 ton for atticStatus: DoneType: MechanicalSub Type: BtmaBusiness Name: Centraire Htg & Air Cond IncApplicant: Jay D MillerFees: $338Effective Date: 2008-01-15Permit Number: 4073703
January 4, 2008
Description: Specify the type of fixtures by entering the quantity in the list below:Status: DoneType: plumbingSub Type: BtpaBusiness Name: Blaylock Plumbing CoApplicant: Jay D MillerFees: $304Effective Date: 2008-01-04Permit Number: 5092258
November 19, 2007
Description: Construct two story rear addition with basement and crawl space to existing single family dwelling. Aaj#1Job Value: $295,000Status: DoneType: RemodelingSub Type: BireBusiness Name: Otogawa Anschel Design BuildApplicant: Jay D MillerFees: $4,171Effective Date: 2007-11-19Permit Number: 3050864
January 24, 2007
Description: plumbing replace water heaterStatus: finalType: plumbingBusiness Name: Mcguire & Sons Plbg & HtgApplicant: Linda C BreitagEffective Date: 2007-01-24Permit Number: BLDG577615
January 7, 2005
Description: DET GAR Construct detached 33 X 22 wood frame garage WITH PORCH AND PATIO. LBF #2 GENERAL COMMENTS: APPLICANT MUST LOCATE AND IDENTIFY THE PROPERTY STAKES AND CALL FOR INSPECTION FOR BUILDING INSPECTOR VERIFICATION BEFORE CONCRETE IS POURED. APPROVED SITE PLAN AND PERMIT MUST BE ON SITE BEFORE INSPECTIONS WILL BE PROVIDED. SEPARATE ELECTRICAL AND MECHANICAL PERMITS REQUIRED FOR ELECTRICAL AND MECHANICAL WORK. Walls, soffits, and fascia closer than 3 feet to property lines not adjacent to public right-of-ways must be protected on the interior and exterior face with 5/8" exterior gypsum sheathing, stucco or other approved materials for fire resistance. Openings (windows, etc.) are not permitted in walls closer than 3 feet to property lines not adjacent to public right-of-ways. 12 ft. maximum average roof height Eaves are not permitted to extend closer than 6 in. to property line Anchor bolts must be within 12 in. of each end of each piece of plate and 6 ft. on center maximum Truss diagraJob Value: $30,000Status: finalType: ResidentialBusiness Name: Dave AlanApplicant: Linda C BreitagEffective Date: 2005-01-07Permit Number: BLDG18682
September 16, 2003
Description: Install 1 service 2 ckts - house remodelStatus: DoneType: ElectricalSub Type: BteaBusiness Name: Suburban ElectricApplicant: Jay D MillerFees: $71Effective Date: 2003-09-16Permit Number: 1060051
August 13, 2003
Description: Construct detached 33 x 22 wood frame garage with porch and patio. Lbf #2Job Value: $30,000Status: DoneType: RemodelingSub Type: BireBusiness Name: David AlanApplicant: Jay D MillerFees: $785Effective Date: 2003-08-13Permit Number: 3023266
January 2, 2002
Description: Replace water heaterStatus: DoneType: plumbingSub Type: BtpaBusiness Name: Mcguire & Sons Plbg & HtgApplicant: Jay D MillerFees: $42Effective Date: 2002-01-02Permit Number: 5027609
June 12, 1997
Description: Rpr 1-ckt residenceStatus: DoneType: ElectricalSub Type: FApplicant: Jay D Miller0Effective Date: 1997-06-12Permit Number: 905811
January 1, 1900
Description: Meter move q2 - 2022 batch #27Status: issuedType: plumbingBusiness Name: Center Point Energy Resource CorpApplicant: Peter B SkriefFees: $85Effective Date: 1900-01-01Permit Number: BLDG977352
January 1, 1900
Description: Sewr repair in streetStatus: completeType: SewerBusiness Name: Cichys Water & SewerApplicant: Peter B SkriefFees: $160Effective Date: 1900-01-01Permit Number: BLDG884843
January 1, 1900
Description: Mudroom addition all new building components shall conform to the provisions of the minnesota energy code as they relate to new construction. Stairs: 7 3/4" maximum riser height 10" minimum tread depth. Guards shall be located along the open sides of stairs ramps and landings that are located more than 30 inches measured vertically to the floor or grade below. A grippable handrail 34"-38" above a line connecting the tread nosings shall be provided on at least one side of each continuous run of treads or flight with four or more risers. Building code: 2020 mnsbc/2018 irc energy code: minnesota rules chapter 1322 separate permits are required for electrical plumbing and heating/air conditioning/ventilation work. A soil erosion control permit is required if more than 500 square feet of ground is disturbed. Applicant is responsible to locate and identify the property stakes and call building inspector for verification inspection before concrete is poured. Refer to the property line locatioJob Value: $34,555Status: filedType: ResidentialApplicant: Peter B SkriefFees: $1,217Effective Date: 1900-01-01Permit Number: BLDG906612
January 1, 1900
Description: Infloor heatStatus: completeType: MechanicalBusiness Name: Practical SystemsApplicant: Peter B SkriefFees: $85Effective Date: 1900-01-01Permit Number: BLDG910833

Current Ownership

Information about the current owner(s).

Property History

2415 22nd St has undefined property events records (listings, deeds, permits, tax, foreclosure, loan).

Property Events

Environment

Environmental factors around 2415 22nd St

School Information

Public/private schools serving 2415 22nd St

Neighborhood

This property is located in Kenwood, Minneapolis, MN 55405.

Market Trends

Historical market data near 2415 22nd St over selected time period.

Nearby Properties on 22nd St