1967 S Drew Ave, Minneapolis, MN 55416 is a 3 bed, 3 bath, 1,941 ft² house built in 1900 on a 0.170 acre lot with 39 construction permits. This house is currently off market. The latest TopHap estimate of the house's value is $860,783.

Property Valuations

Latest estimates for 1967 S Drew Ave based on TopHap automated valuation model (AVM).

Permits

1967 S Drew Ave has 39 permit records of total value of $557,800.

Permit History
39
Permits
$557,800
Total Permit Value
June 2, 2022
Description: Wire attic air conditioningStatus: finalType: Electrical permitSub Type: One-family dwellingApplicant: John HoltFees: $36Effective Date: 2022-06-02Permit Number: ELE2205-08350
May 16, 2019
Project Name: Holman - HoltDescription: Over or underStatus: finalType: Electrical permit; Ele exst 1 or 2 familySub Type: One and two family dwelling; Business Name: Jz Electric IncApplicant: John HoltFees: $36Effective Date: 2019-05-16Permit Number: ELE1905-04728
April 23, 2019
Description: Deck and screen porchStatus: finalType: Electrical permitSub Type: One and two family dwellingFees: $71Effective Date: 2019-04-23Permit Number: ELE1901-05280
March 23, 2016
Description: | Scope of work: REPLACE FURNACE AND AC 1 _______________________________________ HVAC WORK AND REPLACEMENT OF BOILER/FURNACE Identify number of each of the existing individual heating/cooling system being replaced, that serves an individual dwelling unit. Indicate the number of systems that apply: __ Replace boiler plus incidental piping __ Replace furnace only with or without A/C** - plenum included (no duct work beyond plenum) __ Add or replace space heating unit REQUIRED FOR INSPECTION 1. HVAC equipment must be sized to ACCA manual J or an equivalent method. Heat loss calculations to be left next to appliances for inspection. Over-sizing heating equipment must not exceed 43% and cooling equipment must not exceed 21%. 2. Documents relative to maintenance and startup testing (orsat) shall be affixed to the mechanical equipment. 3. All work done under this permit must be completed by a person with the proper Minneapolis installer competency card employed by the Minneapolis licensed peStatus: finalType: MechanicalBusiness Name: Standard Heating & Air Conditioning IncApplicant: Leslie A HolmanEffective Date: 2016-03-23Permit Number: BLDG347110
December 30, 2015
Description: Replace furnace and air conditioning 1Status: OpenType: HVAC alterationsSub Type: BtmbBusiness Name: Standard Heating & Air ConditioningApplicant: John Gregory HoltFees: $128Effective Date: 2015-12-30Permit Number: 4116297
March 27, 2013
Description: PLUMB MOVE METER FROM INSIDE BUILDING TO OUTSIDE BUILDING Properly plug the unused plumbing openings at the nearest live main or branch on the waste and vent system. Cement is not an acceptable method of disconnect. Approved plumbing materials must be used. Dead ends are not permitted except where necessary to extend piping for a cleanout so as to be accessible. The work must be done by a licensed plumbing contractor in which a permit and inspection is required before concealing. Carbon monoxide detectors are required in dwelling units in accordance with Minnesota Statute 299F.50. Please refer to the following website for additional information. http://www.doli.state.mn.us/pdf/bcs_co_detectors_joint_memo_july06.pdf Plans approved by both the State of Minnesota Department of Health and the Department of Labor and Industry are required to be on site for all plumbing work conducted in hospitals, nursing homes, supervised living facilities, outpatient surgical centers, boarding care homes,Status: finalType: PlumbingBusiness Name: Centerpoint EnergyApplicant: Leslie A Holman0Effective Date: 2013-03-27Permit Number: BLDG472993
August 26, 2010
Description: Move meter from inside building to outside buildingStatus: DoneType: plumbingSub Type: BtpaBusiness Name: Centerpoint EnergyApplicant: Leslie HolmanFees: $77Effective Date: 2010-08-26Permit Number: 5120427
August 24, 2010
Description: MECH MECH | WARM AIR HEATING SYSTEMS | Scope of work: INSTALL A/C FOR UPPER BEDROOM - MISC. DUCTWORK, VENT DRYER, VENT EXHAUST FANS (3) Carbon monoxide detectors are required in dwelling units in accordance with Minnesota Statute 299F.50. Please refer to the following website for additional information. http://www.doli.state.mn.us/pdf/bcs_co_detectors_joint_memo_july06.pdf HVAC equipment is allowed as a permitted obstruction in a required side or rear yard as follows: Air-conditioning systems, heating, ventilating, and filtering equipment, not to exceed four (4) feet in height and adjacent to a nonresidential use or adjacent to a residential use which is equipped with central air conditioning or which has no windows or doors in the wall immediately abutting the yard. Such equipment may project into a corner side yard, provided such equipment is located no closer than three (3) feet from the corner side lot line. In no case shall any permitted obstruction be located closer than one (1) Status: finalType: MechanicalApplicant: Leslie A HolmanEffective Date: 2010-08-24Permit Number: BLDG323376
August 24, 2010
Description: MECH | Scope of work: move/repipe gas meter from inside to outside. Carbon monoxide detectors are required in dwelling units in accordance with Minnesota Statute 299F.50. Please refer to the following website for additional information. http://www.doli.state.mn.us/pdf/bcs_co_detectors_joint_memo_july06.pdf HVAC equipment is allowed as a permitted obstruction in a required side or rear yard as follows: Air-conditioning systems, heating, ventilating, and filtering equipment, not to exceed four (4) feet in height and adjacent to a nonresidential use or adjacent to a residential use which is equipped with central air conditioning or which has no windows or doors in the wall immediately abutting the yard. Such equipment may project into a corner side yard, provided such equipment is located no closer than three (3) feet from the corner side lot line. In no case shall any permitted obstruction be located closer than one (1) foot from the property line. If you have any questions, please call Status: finalType: MechanicalApplicant: Leslie A HolmanEffective Date: 2010-08-24Permit Number: BLDG340191
July 22, 2010
Description: Replace existing water heaterStatus: DoneType: plumbingSub Type: BtpaBusiness Name: Hunts Plumbing IncApplicant: Leslie HolmanFees: $77Effective Date: 2010-07-22Permit Number: 5118870
July 16, 2010
Description: Gas fix gas fixture replace/install - is this a new install(y/n)?___n_ - is this a replacement(y/n)?___y_ - fireplace(y/n)?__y_ - stove(y/n)?__n__ - dryer(y/n)?__n__ - water heater(y/n)?__n__ - gas grill(y/n)?____n - other: describe below carbon monoxide detectors are required in dwelling units in accordance with minnesota statute 299f.50. Please refer to the following website for additional information. Http://www.doli.state.mn.us/pdf/bcs_co_detectors_joint_memo_july06.pdfStatus: finalType: plumbingBusiness Name: Fireside Hearth & HomeApplicant: Leslie A HolmanEffective Date: 2010-07-16Permit Number: BLDG489399
June 30, 2010
Description: Move/repipe gas meter from inside to outsideStatus: DoneType: MechanicalSub Type: BtmaBusiness Name: Seasonal ControlApplicant: Leslie HolmanFees: $72Effective Date: 2010-06-30Permit Number: 4091817
June 2, 2010
Description: Construct 2nd floor addition to existing single family house. Aaj#2Status: DoneType: RemodelingSub Type: BireBusiness Name: Buffalo Building And Remodeling IncApplicant: Leslie HolmanFees: $72Effective Date: 2010-06-02Permit Number: 3065297
April 26, 2010
Description: Gas fixture replace/installStatus: DoneType: plumbingSub Type: BtpaBusiness Name: Fireside Hearth & HomeApplicant: Leslie HolmanFees: $72Effective Date: 2010-04-26Permit Number: 5116153
April 23, 2010
Description: Variance to reduce the front yard setback along drew avenue south to allow for a second floor addition to an existing single family dwelling on a reverse corner lot in the r1 districtStatus: OpenType: Master land use applicationSub Type: BzzBusiness Name: Leslie HolmanApplicant: Leslie HolmanFees: $200Effective Date: 2010-04-23Permit Number: 4774
April 21, 2010
Description: Partial gut interior and full remodel windows doors siding partial roof at single family dwelling (jag # 2)Job Value: $200,000Status: DoneType: RemodelingSub Type: BireBusiness Name: Buffalo Building And Remodeling IncApplicant: Leslie HolmanFees: $3,371Effective Date: 2010-04-21Permit Number: 3064515
April 21, 2010
Description: Remodel 2 bathrooms and 1 new: 3 wc 2 bt 4 bn 1 sw; addition laundry hook-up; 1 kitchen sink 1 gas range 1 gas fireplace 1 gas line only for unit heater in garage (appliance to be connected by another contr)Job Value: $9,000Status: DoneType: plumbingSub Type: BtpaBusiness Name: Hunts Plumbing IncApplicant: Leslie HolmanFees: $612Effective Date: 2010-04-21Permit Number: 5115893
March 26, 2010
Description: Install air conditioning for upper bedroom - misc. Ductwork vent dryer vent exhaust fans (3)Status: DoneType: MechanicalSub Type: BtmaBusiness Name: Seasonal ControlApplicant: Leslie HolmanFees: $76Effective Date: 2010-03-26Permit Number: 4089620
March 22, 2010
Description: INTERIOR DEMO ONLY FOR SFD (MAA #02) SEPARATE PERMIT WILL BE PULLED FOR REMODEL. SEPARATE PERMITS ARE REQUIRED FOR ELECTRICAL, PLUMBING, AND HEATING/AIR CONDITIONING/VENTILATION WORK. CARBON MONOXIDE ALARMS REQUIRED IN ACCORDANCE WITH MN. STAT. 299F.50 IRC 313.2.1. When interior alterations, repairs or additions require a building permit or when one or more sleeping rooms are added or created in existing dwellings, smoke detection shall be installed: A. on each level of the house B. iJob Value: $4,000Status: ClosedType: Residential Building PermitSub Type: ResBusiness Name: BUFFALO BUIDING AND REMODELING INCApplicant: JOHN GREGORY HOLTFees: $124Effective Date: 2010-03-22Permit Number: BLDG32803
March 22, 2010
Description: Interior demolish only for single family dwelling (maa #02)Job Value: $4,000Status: DoneType: RemodelingSub Type: BireBusiness Name: Buffalo Buiding And Remodeling IncApplicant: Leslie HolmanFees: $124Effective Date: 2010-03-22Permit Number: 3063907
October 27, 2006
Description: REROOF TEAR-OFF & REROOF SOUTH SIDE OF HOUSE ONLY. All exterior work to be completed within one year of permit issuance per Minneapolis City Ordinance Section 89.165.Status: finalType: ResidentialApplicant: Leslie A HolmanEffective Date: 2006-10-27Permit Number: BLDG79800
November 3, 2004
Description: Dumpster in street 11/8/04 - 11/12/04Status: DoneType: Street use permitSub Type: BsuBusiness Name: Severson ScottApplicant: Leslie HolmanFees: $16Effective Date: 2004-11-03Permit Number: 1015902
June 16, 2004
Description: Remove existing roof material and replace with newJob Value: $2,600Status: DoneType: Building over the counterSub Type: BotcApplicant: Leslie HolmanFees: $90Effective Date: 2004-06-16Permit Number: 1055262
November 21, 2002
Description: Tear-off & reroof south side of house onlyJob Value: $2,900Status: DoneType: Building over the counterSub Type: BotcBusiness Name: Home Update CompanyApplicant: Leslie HolmanFees: $88Effective Date: 2002-11-21Permit Number: 1047550
November 21, 2002
Description: Dumpster in street 11/25/02 - 12/25/02Status: DoneType: Street use permitSub Type: BsuBusiness Name: Home Update CompanyApplicant: Leslie HolmanFees: $15Effective Date: 2002-11-21Permit Number: 1011445
November 20, 1992
Description: Rpl 2 30a ckt (furnace & a/c) residenceJob Value: $250Status: DoneType: ElectricalSub Type: FApplicant: Leslie Holman0Effective Date: 1992-11-20Permit Number: 860960
November 20, 1992
Description: Rpl 2 30a ckt (furnace & a/c) residenceJob Value: $200Status: DoneType: ElectricalSub Type: FApplicant: Leslie Holman0Effective Date: 1992-11-20Permit Number: 860958
November 13, 1992
Description: Instl, air conditioning, pw, 1at80gas-br, residenceStatus: DoneType: Gas burnerSub Type: QmApplicant: Leslie Holman0Effective Date: 1992-11-13Permit Number: 78982
February 13, 1984
Description: Instl front stair addition (v2015)Job Value: $500Status: DoneType: BuildingSub Type: BApplicant: Leslie Holman0Effective Date: 1984-02-13Permit Number: 526541
December 16, 1983
Description: Addition above exist sf dwlg & resideJob Value: $36,500Status: DoneType: BuildingSub Type: BApplicant: Leslie Holman0Effective Date: 1983-12-16Permit Number: 526004
January 1, 1900
Description: Replace fan coilStatus: issuedType: MechanicalBusiness Name: Hero Home Services INCApplicant: Leslie A HolmanFees: $85Effective Date: 1900-01-01Permit Number: BLDG946578
January 1, 1900
Description: plumbing remodel 2 bathrooms and 1 new: 3 wc 2 bt 4 bn 1 sw; addition laundry hook-up; 1 kitchen sink 1 gas range 1 gas fireplace 1 gas line only for unit heater in garage (appliance to be connected by another contr). Properly plug the unused plumbing openings at the nearest live main or branch on the waste and vent system. Cement is not an acceptable method of disconnect. Approved plumbing materials must be used. Dead ends are not permitted except where necessary to extend piping for a cleanout so as to be accessible. The work must be done by a licensed plumbing contractor in which a permit and inspection is required before concealing. Carbon monoxide detectors are required in dwelling units in accordance with minnesota statute 299f.50. Please refer to the following website for additional information. Http://www.doli.state.mn.us/pdf/bcs_co_detectors_joint_memo_july06.pdfStatus: completeType: plumbingBusiness Name: Hunts Plumbing INCApplicant: Leslie A HolmanEffective Date: 1900-01-01Permit Number: BLDG502590
January 1, 1900
Description: Water htr replace existing water heater - is this a gas water heater(y/n)?__y_, 40000 btu - is this an electric water heater(y/n)?__ note: an electric water heater replacement also requires an electrical permit - other: describe below carbon monoxide detectors are required in dwelling units in accordance with minnesota statute 299f.50. Please refer to the following website for additional information. Http://www.doli.state.mn.us/pdf/bcs_co_detectors_joint_memo_july06.pdfStatus: completeType: plumbingBusiness Name: Hunts Plumbing INCApplicant: Leslie A HolmanEffective Date: 1900-01-01Permit Number: BLDG594739
January 1, 1900
Description: Roof to remove existing roof material and replace with new - house (y/n)?__y___ - garage(y/n)?__n___ - will ventilation be added (y/n)?____ - will roof sheathing be repaired/replaced (y/n)?__y__ - other: describe below 20 x 18 section on north side of house, slightly pitched rubber roof to be redecked and reroofed are you placing a dumpster or pod on the public right-of-way (street boulevard sidewalk or alley)? if yes you must obtain a street use permit. Please contact the permit counter at 612-673-5800. M.c.o. 89.165 completion of work - all work for altering repairing or remodeling the exterior portion of a single-family dwelling or two-family dwelling including an attached or detached garage shall be completed within one 1) year from the date of issuance of the building permitJob Value: $2,600Status: completeType: ResidentialBusiness Name: Scott Severson HomeownerApplicant: Leslie A HolmanEffective Date: 1900-01-01Permit Number: BLDG86469
January 1, 1900
Description: *irc1-add construct 2nd floor addition to existing single family house. Aaj#2. ***note: the value of this project was incorporated into existing permit # bire 3064515 when permit was issued for remodeling of existing building. This addition was not reviewed then due to variance from zoning department. See scope of work for permit # bire 3064515 for details*** - install new stud and partition walls to enclose new 15'5 x 22'4 master bedroom suite with 4 feet cantilevered balcony on existing flat roof per structural engineer's design. - insulate walls and roof ceiling per code requirement. - install 4'0 x 12'0 wood framed cantilevered balcony. - upgrade electrical plumbing and mechanical work per code requirement. ***note: structural engineer of record is engineer christian soltermann P.E. # 25085*** engineer of record is to make periodic inspections and upon completion of work. Submit a letter to the city of minneapolis - inspections department stating work was completed to specificationStatus: completeType: ResidentialBusiness Name: Buffalo Bldg & Remodeling INCApplicant: Leslie A HolmanEffective Date: 1900-01-01Permit Number: BLDG31794
January 1, 1900
Description: *irc1-r/r partial gut interior and full remodel windows doors siding partial roof at single family dwelling (jag # 2) ***06/02/10 - additional permit is issued for proposed addition under permit # bire t48705. See plan for detailed scope of work to be done - aaj*** ***value for project includes addition not reviewed this application. Variance for zoning needed*** contractor is aware that refund if variance not approved will be minimal.*** minimum permit for addition. Basement: remove 1 bedroom for family room area new beam for larger stairwell area with removed wall (engineer). Main floor: full kitchen remodel with 1/2 bathroom replacing sauna and bathroom area. Replace class a fireplace with new gas unit same chase. Revise floor framing for flush floor (engineer). New patio door to replace window under existing header to existing deck area off dining room. Second floor: replace rotted rafters as needed (engineer) (hot roof with edpm roofing). Extend closet area into existing hall areaJob Value: $200,000Status: completeType: ResidentialBusiness Name: Buffalo Bldg & Remodeling INCApplicant: Leslie A HolmanEffective Date: 1900-01-01Permit Number: BLDG41119
January 1, 1900
Description: Construct rear deck with screened in portion and new front entry porch. Sck#2 separate permits are required for electrical plumbing and heating/air conditioning/ventilation work. Carbon monoxide alarms required in accordance with mn. Stat. 299f.50 irc 313.2.1. When interior alterations repairs or additions require a building permit or when one or more sleeping rooms are added or created in existing dwellings smoke detection shall be installed: a. On each level of the house b. In each bedroom c. In the hall or room outside of bedrooms. Exceptions: 1. Smoke alarms in existing areas shall not be required to be interconnected and hardwired where the alterations or repairs do not result in the removal of interior wall or ceiling finishes exposing the structure unless there is a crawl space or basement available which could provide access for hardwiring and interconnection without the removal of interior finishes. 2. Work on the exterior which does not require entry into the interior for insJob Value: $71,000Status: completeType: ResidentialBusiness Name: Castle Building & Remodeling INCApplicant: Leslie A HolmanFees: $1,933Effective Date: 1900-01-01Permit Number: BLDG737792
January 1, 1900
Description: Reroof single family dwellingJob Value: $24,250Status: completeType: ResidentialBusiness Name: Sela Roofing & Remodeling INCApplicant: Leslie A HolmanFees: $579Effective Date: 1900-01-01Permit Number: BLDG767255
January 1, 1900
Description: Replace water heaterStatus: completeType: plumbingBusiness Name: Uptown Plumbing Heating & CoolingApplicant: Leslie A HolmanFees: $84Effective Date: 1900-01-01Permit Number: BLDG758136

Current Ownership

Information about the current owner(s).

Property History

1967 S Drew Ave has undefined property events records (listings, deeds, permits, tax, foreclosure, loan).

Property Events

Environment

Environmental factors around 1967 S Drew Ave

School Information

Public/private schools serving 1967 S Drew Ave

Neighborhood

This property is located in Mcnair Park, Minneapolis, MN 55416.

Market Trends

Historical market data near 1967 S Drew Ave over selected time period.

Nearby Properties on Drew Ave