08/13/2015
Sold Price
$405,000$97/ft²

1105 Se 6th St
Minneapolis, MN 55414

1105 Se 6th St, Minneapolis, MN 55414 is a 10 bed, 4 bath, 4,172 ft² multi-family home house built in 1918 on a 0.200 acre lot with 17 construction permits. This multi-family home is currently off market, and it was last sold in 2015 for $405,000. The latest TopHap estimate of the multi-family home's value is $785,000.

Property Valuations

Latest estimates for 1105 Se 6th St based on TopHap automated valuation model (AVM).

Permits

1105 Se 6th St has 17 permit records of total value of $221,750.

Permit History
17
Permits
$221,750
Total Permit Value
December 6, 2022
Description: Basement finish wiringStatus: finalType: Electrical permitSub Type: Two-family dwellingApplicant: Go Gopher RentalsFees: $71Effective Date: 2022-12-06Permit Number: ELE2211-04942
August 30, 2016
Description: *IRC2-ADD TWO STORY ADDITION TO DUPLEX WITH NON-HABITABLE CRAWL SPACE. BEDROOM, STUDY ROOM & BATHROOM ON (AGY) 1ST AND 2ND FLOOR. #02 SEPARATE PERMITS ARE REQUIRED FOR ELECTRICAL, PLUMBING, AND HEATING/AIR CONDITIONING/VENTILATION WORK. THIS WORK MUST BE COMPLETED BY A LICENSED CONTRACTOR IN A MULTI-FAMILY DWELLING. A SOIL EROSION CONTROL PERMIT IS REQUIRED IF MORE THAN 500 SQUARE FEET OF GROUND IS DISTURBED. APPLICANT IS RESPONSIBLE TO LOCATE AND IDENTIFY THE PROPERTY STAKES AND CALL BUILDING INSPECTOR FOR VERIFICATION INSPECTION BEFORE CONCRETE IS POURED. REFER TO THE PROPERTY LINE LOCATION BULLETIN FOR INFORMATION ON HOW TO FIND YOUR PROPERTY LINE. APPROVED PLANS AND PERMIT MUST BE ON SITE BEFORE INSPECTIONS WILL BE PROVIDED. PROTECTION OF ADJOINING PROPERTY: APPLICANT IS REQUIRED TO TAKE MEASURES TO ENSURE EXCAVATION DOES NOT CAUSE DAMAGE TO ADJOINING PROPERTY WITH SHORING OR OTHER METHODS THAT EMPLOY BEST PRACTICES. CARBON MONOXIDE ALARMS REQUIRED IN ACCORDANCE WITH MN. STAT. 299FStatus: finalType: ResidentialApplicant: 1105 6 Th St Se LlcEffective Date: 2016-08-30Permit Number: BLDG75192
August 29, 2016
Description: PLUM FIX Specify the type of fixtures by entering the quantity in the list below: Water Closets__4__ Urinals_____ Bath Tubs__2__ Basins__6__ Sinks___2__ Wash Trays__2___ Showers___2__ Floor Drains__1__ Extensions_____ Misc Fixtures__3__ Electric Water Heaters_____ Other: Specify below HOUSE ADDITION IN REAR - 22 FIXTURES GAS APPLIANCES: (2) GAS STOVES @ 35,000 BTU'S EACH & (2) GAS WATER HEATERS @ 55,000 BTU'S EACH MISC FIXTURES: (1) HOSE BIB, (2) DISHWASHERS Properly plug the unused plumbing openings at the nearest live main or branch on the waste and vent system. Cement is not an acceptable method of disconnect. Approved plumbing materials must be used. Dead ends are not permitted except where necessary to extend piping for a cleanout so as to be accessible. The work must be done by a licensed plumbing contractor in which a permit and inspection is required before concealing. Carbon monoxide detectors are required in dwelling units in accordance with Minnesota Statute 299F.50. Please Status: finalType: PlumbingApplicant: 1105 6 Th St Se LlcEffective Date: 2016-08-29Permit Number: BLDG577108
August 25, 2016
Description: | Scope of work: (2) furnaces (2) AC ductwork (4) fans (2) dryer vents _______________________________________ HVAC WORK AND ENTIRE SYSTEM REPLACEMENT ** NO NEW CONSTRUCTION - Tear-downs and major remodels are considered new construction ** Identify number of each of the existing individual heating/cooling system being replaced, that serves an individual dwelling unit. Indicate the number of systems that apply: __Remove existing system and install new (boiler or forced air system) __Install a new system to serve an existing non-conditioned space REQUIRED FOR INSPECTION 1. HVAC equipment must be sized to ACCA manual J or an equivalent method. Heat loss calculations to be left next to appliances for inspection. Over-sizing of heating equipment must not exceed 43% and cooling equipment must not exceed 21%. 2. Documents relative to maintenance and startup testing (orsat) shall be affixed to the mechanical equipment. 3. All work done under this permit must be completed by a person with the Status: finalType: MechanicalBusiness Name: Swift Heating & Air Conditioning IncApplicant: 1105 6 Th St Se LlcEffective Date: 2016-08-25Permit Number: BLDG363690
August 22, 2016
Project Name: Whole House RehabDescription: Whole house rehabStatus: finalType: Ele exst 1 or 2 familyBusiness Name: M Jones Electric LLCApplicant: Go Gopher RentalsFees: $271Effective Date: 2016-08-22Permit Number: ELE1607-00807
June 16, 2016
Description: (2) furnaces (2) air conditioning ductwork (4) fans (2) dryer ventsStatus: OpenType: HVAC alterationsSub Type: BtmbBusiness Name: Swift MechanicalApplicant: 1105 6th St Se LlcFees: $209Effective Date: 2016-06-16Permit Number: 4118480
June 8, 2016
Description: GAS FIX Gas fixture replace/install - Is this a new install(y/n)?____ - Is this a replacement(y/n)?____ - Fireplace(y/n)?___ - Stove(y/n)?___Y_ - Dryer(y/n)?____ - Water Heater(y/n)?____ - Gas grill(y/n)?____ - Other: describe below Carbon monoxide detectors are required in dwelling units in accordance with Minnesota Statute 299F.50. Please refer to the following website for additional information. http://www.doli.state.mn.us/pdf/bcs_co_detectors_joint_memo_july06.pdfStatus: finalType: PlumbingBusiness Name: Centerpoint EnergyApplicant: 1105 6 Th St Se LlcEffective Date: 2016-06-08Permit Number: BLDG491227
June 3, 2016
Description: Specify the type of fixtures by entering the quantity in the list below:Status: OpenType: plumbingSub Type: BtpaBusiness Name: All Pride PlumbingApplicant: 1105 6th St Se LlcFees: $1,159Effective Date: 2016-06-03Permit Number: 5194389
January 13, 2016
Description: Two story addition to duplex with non-habitable crawl space. Bedroom study room & bathroom on (agy) 1st and 2nd floor. #02Job Value: $148,000Status: OpenType: RemodelingSub Type: BireBusiness Name: Matthew Kraskey ConstructionApplicant: 1105 6th St Se LlcFees: $3,055Effective Date: 2016-01-13Permit Number: 3102471
September 29, 2015
Description: PLUM FIX Remodel existing 2nd floor full bath. Install new electric water heater. _______________________________________ Specify the type of fixtures by entering the quantity in the list below: Water Closets____ Urinals_____ Bath Tubs____ Basins____ Sinks_____ Wash Trays_____ Showers_____ Floor Drains____ Extensions_____ Misc Fixtures____ Electric Water Heaters_____ Other: Specify below Properly plug the unused plumbing openings at the nearest live main or branch on the waste and vent system. Cement is not an acceptable method of disconnect. Approved plumbing materials must be used. Dead ends are not permitted except where necessary to extend piping for a cleanout so as to be accessible. The work must be done by a licensed plumbing contractor in which a permit and inspection is required before concealing. Carbon monoxide detectors are required in dwelling units in accordance with Minnesota Statute 299F.50. Please refer to the following website for additional information. http://www.dlStatus: finalType: PlumbingApplicant: 1105 6 Th St Se LlcEffective Date: 2015-09-29Permit Number: BLDG560407
September 29, 2015
Description: Remodel existing 2nd floor full bathroom. Install new electric water heaterStatus: OpenType: plumbingSub Type: BtpaBusiness Name: All Pride PlumbingApplicant: Astrid V SwainFees: $160Effective Date: 2015-09-29Permit Number: 5184156
October 25, 2011
Description: Gas fixture replace/installStatus: OpenType: plumbingSub Type: BtpaBusiness Name: Centerpoint Energy Minnesota GasApplicant: Astrid V SwainFees: $79Effective Date: 2011-10-25Permit Number: 5132704
August 28, 2006
Description: R3/REM Building Permit for existing deck repairs and for new storm door. GM (no plans required) SEPARATE PERMITS ARE REQUIRED FOR ELECTRICAL, PLUMBING, AND HEATING/AIR CONDITIONING/VENTILATION WORK. R317.1.1 Alterations, repairs or additions. When interior alterations, repairs or additions requiring a permit occur, or when one or more sleeping rooms are added or created in existing dwellings, the individual dwelling unit shall be provided with smoke alarms located as required for new dwellings; the smoke alarms shall be interconnected and hardwired. Exceptions: 1. Smoke alarms in existing areas shall not be required to be interconnected and hardwired where the alterations or repairs do not result in the removal of interior wall or ceiling finishes exposing the structure, unless there is a crawl space or basement available which could provide access for hardwiring and interconnection without the removal of interior finishes. 2. Work on the exterior which does not require entry into the Status: finalType: CommercialApplicant: 1105 6 Th St Se LlcEffective Date: 2006-08-28Permit Number: BLDG225455
July 18, 2006
Description: Building permit for existing deck repairs and for new storm door. Gm (no plans required)Job Value: $4,750Status: DoneType: RemodelingSub Type: BireBusiness Name: City Venture CorporationApplicant: Astrid V SwainFees: $129Effective Date: 2006-07-18Permit Number: 3042566
July 31, 1986
Description: 10x12 rear 3-season porch; 10x10 deckJob Value: $4,000Status: DoneType: BuildingSub Type: BApplicant: Astrid V Swain0Effective Date: 1986-07-31Permit Number: 545189
January 1, 1900
Description: Basement remodel at duplex (maa) sound/fire test assembly____________ separate permits are required for electrical plumbing and heating/air conditioning/ventilation work. This work must be completed by a licensed contractor in a multi-family dwelling. Carbon monoxide alarms required in accordance with mn. Stat. 299f.50 irc 313.2.1. When interior alterations repairs or additions require a building permit or when one or more sleeping rooms are added or created in existing dwellings smoke detection shall be installed: a. On each level of the house b. In each bedroom c. In the hall or room outside of bedrooms. Exceptions: 1. Smoke alarms in existing areas shall not be required to be interconnected and hardwired where the alterations or repairs do not result in the removal of interior wall or ceiling finishes exposing the structure unless there is a crawl space or basement available which could provide access for hardwiring and interconnection without the removal of interior finishes. 2. WoJob Value: $65,000Status: filedType: ResidentialBusiness Name: GGR Restoration LLCApplicant: 1105 6 Th St SE LLCFees: $1,503Effective Date: 1900-01-01Permit Number: BLDG955981
January 1, 1900
Description: Install all new drain waste vent and water lines in basement 3/4 bathroom and install new bathtub toilet and lavatoryStatus: issuedType: plumbingBusiness Name: ALL Pride Plumbing INCApplicant: 1105 6 Th St SE LLCFees: $125Effective Date: 1900-01-01Permit Number: BLDG967270

Current Ownership

Information about the current owner(s).

Property History

1105 Se 6th St has undefined property events records (listings, deeds, permits, tax, foreclosure, loan).

Property Events

Environment

Environmental factors around 1105 Se 6th St

School Information

Public/private schools serving 1105 Se 6th St

Neighborhood

This property is located in University, Minneapolis, MN 55414.

Market Trends

Historical market data near 1105 Se 6th St over selected time period.

Nearby Properties on 6th St