  • Chat with Us
  • Submit Feedback
  • TopHap Academy
  • What's New?
Residential > Multi-family
Sold
05/04/2015
Sold Price
$205,000$73/ft²

1002 Se 13 Th Ave
Minneapolis, MN 55414

1002 Se 13 Th Ave, Minneapolis, MN 55414 is a 9 bed, 5 bath, 2,814 ft² multi-family home house built in 1908 on a 0.120 acre lot with 16 construction permits. This multi-family home is currently off market, and it was last sold in 2015 for $205,000. The latest TopHap estimate of the multi-family home's value is $592,000.

Property Valuations

Latest estimates for 1002 Se 13 Th Ave based on TopHap automated valuation model (AVM).

Permits

1002 Se 13 Th Ave has 16 permit records of total value of $209,600.

Permit History
16
Permits
$209,600
Total Permit Value
October 12, 2017
Description: 30 day dumpsterStatus: OpenType: Street use permitSub Type: StreetuseBusiness Name: SCHILL'S Dumpster Service IncApplicant: Gogopher Rentals LLCFees: $81Effective Date: 2017-10-12Permit Number: BLDG678809
December 3, 2015
Description: *IRC2-R/R DEMO/REBUILD 8x22 FRONT PORCH AND STEPS, REBUILD REAR STOOP/STEPS AT DUPLEX (LAH) NO CHANGES TO EXITING OR ASSEMBLIES SOUND/FIRE TEST ASSEMBLY N/A SEPARATE PERMITS ARE REQUIRED FOR ELECTRICAL, PLUMBING, AND HEATING/AIR CONDITIONING/VENTILATION WORK. THIS WORK MUST BE COMPLETED BY A LICENSED CONTRACTOR IN A MULTI-FAMILY DWELLING. CARBON MONOXIDE ALARMS REQUIRED IN ACCORDANCE WITH MN. STAT. 299F.50 IRC 313.2.1. When interior alterations, repairs or additions require a building permit or when one or more sleeping rooms are added or created in existing dwellings, smoke detection shall be installed: A. on each level of the house B. in each bedroom C. in the hall or room outside of bedrooms. Exceptions: 1. Smoke alarms in existing areas shall not be required to be interconnected and hardwired where the alterations or repairs do not result in the removal of interior wall or ceiling finishes exposing the structure, unless there is a crawl space or basement available which could proviStatus: finalType: ResidentialApplicant: Go Gopher Rentals LlcEffective Date: 2015-12-03Permit Number: BLDG50583
October 9, 2015
Job Value: $9,800Status: OpenType: RemodelingSub Type: BireBusiness Name: Matthew Kraskey ConstructionApplicant: Gogopher Rentals LlcFees: $431Effective Date: 2015-10-09Permit Number: 3100951
August 28, 2015
Description: PLUM FIX Specify the type of fixtures by entering the quantity in the list below: Water Closets__4__ Urinals_____ Bath Tubs____ Basins__4__ Sinks___2__ Wash Trays__2___ Showers__2___ Floor Drains__1__ Extensions_____ Misc Fixtures_3___ Electric Water Heaters_____ Other: Specify below REMODEL - 20 FUXTURES - INCLUDE (3) MISC FIXTURES: (1) HOSE BIB, (2) DISHWASHERS (2) GAS WATER HEATERS - 50,000 BTU'S & (2) GAS STOVES - 35,000 BTU'S Properly plug the unused plumbing openings at the nearest live main or branch on the waste and vent system. Cement is not an acceptable method of disconnect. Approved plumbing materials must be used. Dead ends are not permitted except where necessary to extend piping for a cleanout so as to be accessible. The work must be done by a licensed plumbing contractor in which a permit and inspection is required before concealing. Carbon monoxide detectors are required in dwelling units in accordance with Minnesota Statute 299F.50. Please refer to the following websiStatus: finalType: PlumbingApplicant: Go Gopher Rentals LlcEffective Date: 2015-08-28Permit Number: BLDG523173
August 28, 2015
Description: *IRC2-R/R REMODEL DUPLEX NEW BEDROOMS IN BASEMENT AND ATTIC PER DEPT BULLETIN (sza) SOUND/FIRE TEST ASSEMBLY___MAINTAIN EXISTING SEPARATE PERMITS ARE REQUIRED FOR ELECTRICAL, PLUMBING, AND HEATING/AIR CONDITIONING/VENTILATION WORK. THIS WORK MUST BE COMPLETED BY A LICENSED CONTRACTOR IN A MULTI-FAMILY DWELLING. CARBON MONOXIDE ALARMS REQUIRED IN ACCORDANCE WITH MN. STAT. 299F.50 IRC 313.2.1. When interior alterations, repairs or additions require a building permit or when one or more sleeping rooms are added or created in existing dwellings, smoke detection shall be installed: A. on each level of the house B. in each bedroom C. in the hall or room outside of bedrooms. Exceptions: 1. Smoke alarms in existing areas shall not be required to be interconnected and hardwired where the alterations or repairs do not result in the removal of interior wall or ceiling finishes exposing the structure, unless there is a crawl space or basement available which could provide access for hardwiring andStatus: finalType: ResidentialApplicant: Go Gopher Rentals LlcEffective Date: 2015-08-28Permit Number: BLDG72107
August 28, 2015
Description: HVAC-LVL3 | Scope of work: HVAC WORK AND ENTIRE SYSTEM REPLACEMENT ** NO NEW CONSTRUCTION - Tear-downs and major remodels are considered new construction ** Identify number of each of the existing individual heating/cooling system being replaced, that serves an individual dwelling unit. Indicate the number of systems that apply: _x_Remove existing system and install new (boiler or forced air system) __Install a new system to serve an existing non-conditioned space REQUIRED FOR INSPECTION 1. HVAC equipment must be sized to ACCA manual J or an equivalent method. Heat loss calculations to be left next to appliances for inspection. Over-sizing of heating equipment must not exceed 43% and cooling equipment must not exceed 21%. 2. Documents relative to maintenance and startup testing (orsat) shall be affixed to the mechanical equipment. 3. All work done under this permit must be completed by a person with the proper Minneapolis installer competency card employed by the Minneapolis licensed pStatus: completeType: MechanicalBusiness Name: Swift Heating & Air Conditioning IncApplicant: Go Gopher Rentals LlcEffective Date: 2015-08-28Permit Number: BLDG343862
August 27, 2015
Project Name: Whole House RemodelDescription: Whole house remodelStatus: finalType: Ele exst 1 or 2 familyBusiness Name: M Jones Electric LLCApplicant: Go GopherFees: $271Effective Date: 2015-08-27Permit Number: ELE1507-03620
July 10, 2015
Description: HVAC work and entire system replacementStatus: DoneType: HVAC alterationsSub Type: BtmbBusiness Name: Swift MechanicalApplicant: Gogopher Rentals LlcFees: $209Effective Date: 2015-07-10Permit Number: 4113669
June 3, 2015
Description: Specify the type of fixtures by entering the quantity in the list below:Status: DoneType: plumbingSub Type: BtpaBusiness Name: All Pride PlumbingApplicant: Gogopher Rentals LlcFees: $1,083Effective Date: 2015-06-03Permit Number: 5180475
May 26, 2015
Description: Remodel duplex new bedrooms in basement and attic per dept bulletin (sza)Job Value: $188,000Status: DoneType: RemodelingSub Type: BireBusiness Name: Matthew Kraskey ConstructionApplicant: Gogopher Rentals LlcFees: $3,603Effective Date: 2015-05-26Permit Number: 3098037
May 6, 2015
Description: Interior non structural demolish of basement (wss)Job Value: $3,500Status: OpenType: RemodelingSub Type: BireBusiness Name: Matthew Kraskey ConstructionApplicant: Gogopher Rentals LlcFees: $232Effective Date: 2015-05-06Permit Number: 3097589
March 19, 2003
Description: Reroof tear off and replace roof on houseStatus: finalType: ResidentialApplicant: Go Gopher Rentals LlcEffective Date: 2003-03-19Permit Number: BLDG193173
June 24, 2002
Description: Tear off and replace roof on houseJob Value: $4,000Status: DoneType: Building over the counterSub Type: BotcBusiness Name: Elite Services, IncApplicant: June R EricksonFees: $103Effective Date: 2002-06-24Permit Number: 1044524
June 24, 2002
Description: Dumpster permit valid 6/25/02 to 7/02/02Status: DoneType: Street use permitSub Type: BsuBusiness Name: Elite ServicesApplicant: June R EricksonFees: $15Effective Date: 2002-06-24Permit Number: 1010538
July 13, 1989
Description: Rebld front porch incl ftgs deck railxJob Value: $800Status: DoneType: BuildingSub Type: BApplicant: June R Erickson0Effective Date: 1989-07-13Permit Number: 566495
January 1, 1900
Description: *irc2-r/r interior non structural demolish of basement (wss) separate permits are required for electrical plumbing and heating/air conditioning/ventilation work. This work must be completed by a licensed contractor in a multi-family dwelling. Carbon monoxide alarms required in accordance with mn. Stat. 299f.50 irc 313.2.1. When interior alterations repairs or additions require a building permit or when one or more sleeping rooms are added or created in existing dwellings smoke detection shall be installed: a. On each level of the house b. In each bedroom c. In the hall or room outside of bedrooms. Exceptions: 1. Smoke alarms in existing areas shall not be required to be interconnected and hardwired where the alterations or repairs do not result in the removal of interior wall or ceiling finishes exposing the structure unless there is a crawl space or basement available which could provide access for hardwiring and interconnection without the removal of interior finishes. 2. Work on theJob Value: $3,500Status: completeType: ResidentialBusiness Name: Matthew Kraskey ConstructionApplicant: Go Gopher Rentals LLCEffective Date: 1900-01-01Permit Number: BLDG70051

Current Ownership

Information about the current owner(s).

Property History

1002 Se 13 Th Ave has undefined property events records (listings, deeds, permits, tax, foreclosure, loan).

Property Events

Environment

Environmental factors around 1002 Se 13 Th Ave

School Information

Public/private schools serving 1002 Se 13 Th Ave

Neighborhood

This property is located in University, Minneapolis, MN 55414.

Market Trends

Historical market data near 1002 Se 13 Th Ave over selected time period.

Nearby Properties on 13 Th Ave